Literature DB >> 26020490

Algorithm-enabled exploration of image-quality potential of cone-beam CT in image-guided radiation therapy.

Xiao Han1, Erik Pearson, Charles Pelizzari, Hania Al-Hallaq, Emil Y Sidky, Junguo Bian, Xiaochuan Pan.   

Abstract

Kilo-voltage (KV) cone-beam computed tomography (CBCT) unit mounted onto a linear accelerator treatment system, often referred to as on-board imager (OBI), plays an increasingly important role in image-guided radiation therapy. While the FDK algorithm is currently used for reconstructing images from clinical OBI data, optimization-based reconstruction has also been investigated for OBI CBCT. An optimization-based reconstruction involves numerous parameters, which can significantly impact reconstruction properties (or utility). The success of an optimization-based reconstruction for a particular class of practical applications thus relies strongly on appropriate selection of parameter values. In the work, we focus on tailoring the constrained-TV-minimization-based reconstruction, an optimization-based reconstruction previously shown of some potential for CBCT imaging conditions of practical interest, to OBI imaging through appropriate selection of parameter values. In particular, for given real data of phantoms and patient collected with OBI CBCT, we first devise utility metrics specific to OBI-quality-assurance tasks and then apply them to guiding the selection of parameter values in constrained-TV-minimization-based reconstruction. The study results show that the reconstructions are with improvement, relative to clinical FDK reconstruction, in both visualization and quantitative assessments in terms of the devised utility metrics.

Entities:  

Mesh:

Year:  2015        PMID: 26020490      PMCID: PMC4610380          DOI: 10.1088/0031-9155/60/12/4601

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  40 in total

Review 1.  Intensity-modulated radiotherapy: current status and issues of interest.

Authors: 
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-11-15       Impact factor: 7.038

Review 2.  Advances in image-guided radiation therapy.

Authors:  Laura A Dawson; David A Jaffray
Journal:  J Clin Oncol       Date:  2007-03-10       Impact factor: 44.544

3.  A quality assurance program for image quality of cone-beam CT guidance in radiation therapy.

Authors:  Jean-Pierre Bissonnette; Douglas J Moseley; David A Jaffray
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

4.  Task Group 142 report: quality assurance of medical accelerators.

Authors:  Eric E Klein; Joseph Hanley; John Bayouth; Fang-Fang Yin; William Simon; Sean Dresser; Christopher Serago; Francisco Aguirre; Lijun Ma; Bijan Arjomandy; Chihray Liu; Carlos Sandin; Todd Holmes
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

5.  Feldkamp and circle-and-line cone-beam reconstruction for 3D micro-CT of vascular networks.

Authors:  R H Johnson; H Hu; S T Haworth; P S Cho; C A Dawson; J H Linehan
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

6.  Optimization-based reconstruction of sparse images from few-view projections.

Authors:  Xiao Han; Junguo Bian; Erik L Ritman; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-07-31       Impact factor: 3.609

7.  Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

Authors:  Xiaochuan Pan; Emil Y Sidky; Michael Vannier
Journal:  Inverse Probl       Date:  2009-01-01       Impact factor: 2.407

8.  Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT.

Authors:  Junguo Bian; Jeffrey H Siewerdsen; Xiao Han; Emil Y Sidky; Jerry L Prince; Charles A Pelizzari; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2010-10-20       Impact factor: 3.609

9.  Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy.

Authors:  Inga S Grills; Geoffrey Hugo; Larry L Kestin; Ana Paula Galerani; K Kenneth Chao; Jennifer Wloch; Di Yan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-10-29       Impact factor: 7.038

10.  A study on adaptive IMRT treatment planning using kV cone-beam CT.

Authors:  George X Ding; Dennis M Duggan; Charles W Coffey; Matthew Deeley; Dennis E Hallahan; Anthony Cmelak; Arnold Malcolm
Journal:  Radiother Oncol       Date:  2007-08-20       Impact factor: 6.280

View more
  7 in total

Review 1.  Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

Authors:  Hao Zhang; Jing Wang; Dong Zeng; Xi Tao; Jianhua Ma
Journal:  Med Phys       Date:  2018-09-10       Impact factor: 4.071

2.  Optimization-based image reconstruction with artifact reduction in C-arm CBCT.

Authors:  Dan Xia; David A Langan; Stephen B Solomon; Zheng Zhang; Buxin Chen; Hao Lai; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2016-10-03       Impact factor: 3.609

3.  Investigation of optimization-based reconstruction with an image-total-variation constraint in PET.

Authors:  Zheng Zhang; Jinghan Ye; Buxin Chen; Amy E Perkins; Sean Rose; Emil Y Sidky; Chien-Min Kao; Dan Xia; Chi-Hua Tung; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2016-07-25       Impact factor: 3.609

4.  Low-Dose CBCT Reconstruction Using Hessian Schatten Penalties.

Authors:  Liang Liu; Xinxin Li; Kai Xiang; Jing Wang; Shan Tan
Journal:  IEEE Trans Med Imaging       Date:  2017-12       Impact factor: 10.048

5.  Artifact reduction in short-scan CBCT by use of optimization-based reconstruction.

Authors:  Zheng Zhang; Xiao Han; Erik Pearson; Charles Pelizzari; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2016-04-05       Impact factor: 3.609

6.  Directional-TV algorithm for image reconstruction from limited-angular-range data.

Authors:  Zheng Zhang; Buxin Chen; Dan Xia; Emil Y Sidky; Xiaochuan Pan
Journal:  Med Image Anal       Date:  2021-03-05       Impact factor: 8.545

7.  Patient-specific calibration of cone-beam computed tomography data sets for radiotherapy dose calculations and treatment plan assessment.

Authors:  Michael MacFarlane; Daniel Wong; Douglas A Hoover; Eugene Wong; Carol Johnson; Jerry J Battista; Jeff Z Chen
Journal:  J Appl Clin Med Phys       Date:  2018-02-26       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.