Intensity-modulated radiotherapy: current status and issues of interest.

.   

Abstract

PURPOSE: To develop and disseminate a report aimed primarily at practicing radiation oncology physicians and medical physicists that describes the current state-of-the-art of intensity-modulated radiotherapy (IMRT). Those areas needing further research and development are identified by category and recommendations are given, which should also be of interest to IMRT equipment manufacturers and research funding agencies. METHODS AND MATERIALS: The National Cancer Institute formed a Collaborative Working Group of experts in IMRT to develop consensus guidelines and recommendations for implementation of IMRT and for further research through a critical analysis of the published data supplemented by clinical experience. A glossary of the words and phrases currently used in IMRT is given in the. Recommendations for new terminology are given where clarification is needed.
RESULTS: IMRT, an advanced form of external beam irradiation, is a type of three-dimensional conformal radiotherapy (3D-CRT). It represents one of the most important technical advances in RT since the advent of the medical linear accelerator. 3D-CRT/IMRT is not just an add-on to the current radiation oncology process; it represents a radical change in practice, particularly for the radiation oncologist. For example, 3D-CRT/IMRT requires the use of 3D treatment planning capabilities, such as defining target volumes and organs at risk in three dimensions by drawing contours on cross-sectional images (i.e., CT, MRI) on a slice-by-slice basis as opposed to drawing beam portals on a simulator radiograph. In addition, IMRT requires that the physician clearly and quantitatively define the treatment objectives. Currently, most IMRT approaches will increase the time and effort required by physicians, medical physicists, dosimetrists, and radiation therapists, because IMRT planning and delivery systems are not yet robust enough to provide totally automated solutions for all disease sites. Considerable research is needed to model the clinical outcomes to allow truly automated solutions. Current IMRT delivery systems are essentially first-generation systems, and no single method stands out as the ultimate technique. The instrumentation and methods used for IMRT quality assurance procedures and testing are not yet well established. In addition, many fundamental questions regarding IMRT are still unanswered. For example, the radiobiologic consequences of altered time-dose fractionation are not completely understood. Also, because there may be a much greater ability to trade off dose heterogeneity in the target vs. avoidance of normal critical structures with IMRT compared with traditional RT techniques, conventional radiation oncology planning principles are challenged. All in all, this new process of planning and treatment delivery has significant potential for improving the therapeutic ratio and reducing toxicity. Also, although inefficient currently, it is expected that IMRT, when fully developed, will improve the overall efficiency with which external beam RT can be planned and delivered, and thus will potentially lower costs.
CONCLUSION: Recommendations in the areas pertinent to IMRT, including dose-calculation algorithms, acceptance testing, commissioning and quality assurance, facility planning and radiation safety, and target volume and dose specification, are presented. Several of the areas in which future research and development are needed are also indicated. These broad recommendations are intended to be both technical and advisory in nature, but the ultimate responsibility for clinical decisions pertaining to the implementation and use of IMRT rests with the radiation oncologist and radiation oncology physicist. This is an evolving field, and modifications of these recommendations are expected as new technology and data become available.

Entities:  

Mesh:

Year:  2001        PMID: 11704310     DOI: 10.1016/s0360-3016(01)01749-7

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  152 in total

Review 1.  Positron emission tomography in pediatric radiation oncology: integration in the treatment-planning process.

Authors:  Matthew J Krasin; Melissa M Hudson; Sue C Kaste
Journal:  Pediatr Radiol       Date:  2004-01-27

2.  Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification.

Authors:  H K Looe; Y Uphoff; D Harder; B Poppe; K C Willborn
Journal:  Strahlenther Onkol       Date:  2012-01-12       Impact factor: 3.621

Review 3.  Volumetric modulated arc therapy: a review of current literature and clinical use in practice.

Authors:  M Teoh; C H Clark; K Wood; S Whitaker; A Nisbet
Journal:  Br J Radiol       Date:  2011-11       Impact factor: 3.039

Review 4.  Management of infection following reconstruction in bone tumors.

Authors:  Sudhir K Kapoor; Rajesh Thiyam
Journal:  J Clin Orthop Trauma       Date:  2015-07-07

Review 5.  Megavoltage quality control, resources and demand: a pragmatic review.

Authors:  John A Mills; Steven J Colligan
Journal:  Br J Radiol       Date:  2016-01-14       Impact factor: 3.039

6.  Ionizing radiations increase the activity of the cell surface glycohydrolases and the plasma membrane ceramide content.

Authors:  Massimo Aureli; Rosaria Bassi; Alessandro Prinetti; Elena Chiricozzi; Brigida Pappalardi; Vanna Chigorno; Nadia Di Muzio; Nicoletta Loberto; Sandro Sonnino
Journal:  Glycoconj J       Date:  2012-05-17       Impact factor: 2.916

7.  Theoretical and empirical investigations of KCl : Eu2+ for nearly water-equivalent radiotherapy dosimetry.

Authors:  Yuanshui Zheng; Zhaohui Han; Joseph P Driewer; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

8.  Recommendations for treatment with IMRT for prostate and head-neck cancer. Axencia de Avaliación de Tecnoloxías Sanitarias de Galicia.

Authors:  M del Carmen Maceira Rozas; Teresa Rey Liste; Angela L García Caeiro; Julio García Comesaña
Journal:  Clin Transl Oncol       Date:  2006-04       Impact factor: 3.405

9.  Analytic IMRT dose calculations utilizing Monte Carlo to predict MLC fluence modulation.

Authors:  I B Mihaylov; F A Lerma; Y Wu; J V Siebers
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

10.  Development of a novel treatment planning test for credentialing rotational intensity-modulated radiotherapy techniques in the UK.

Authors:  Y Tsang; L Ciurlionis; C Clark; K Venables
Journal:  Br J Radiol       Date:  2013-02       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.