Literature DB >> 9572516

Feldkamp and circle-and-line cone-beam reconstruction for 3D micro-CT of vascular networks.

R H Johnson1, H Hu, S T Haworth, P S Cho, C A Dawson, J H Linehan.   

Abstract

Detailed morphometric knowledge of the microvascular network is needed for studies relating structure to haemodynamic function in organs like the lung. Clinical volumetric CT is limited to millimetre-order spatial resolution. Since evidence suggests that small arterioles (50 to 300 micrometres) dominate pulmonary haemodynamics, we built a micro-CT scanner, capable of imaging excised lungs in 3D with 100 microm resolution, for basic physiology research. The scanner incorporates a micro-focal (3 microm) x-ray source, an xyz theta stage and a CCD-coupled image intensifier detector. We imaged phantoms and contrast-enhanced rat lungs, reconstructing the data with either the Feldkamp or the circle-and-line cone-beam reconstruction algorithm. We present reconstructions using 180 views over 360 degrees for the circular trajectory, augmented with views from a linear scan for the circle-and-line algorithm. Especially for platelike features perpendicular to the rotation axis and remote from the midplane, the circle-and-line algorithm produces superior reconstructions compared with Feldkamp's algorithm. We conclude that the use of nonplanar source trajectories to perform micro-CT on contrast-enhanced, excised lungs can provide data useful for morphometric analysis of vascular trees, currently down to the 130 microm level.

Entities:  

Mesh:

Year:  1998        PMID: 9572516     DOI: 10.1088/0031-9155/43/4/020

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

Review 1.  High resolution X-ray computed tomography: an emerging tool for small animal cancer research.

Authors:  M J Paulus; S S Gleason; S J Kennel; P R Hunsicker; D K Johnson
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

2.  System for the analysis and visualization of large 3D anatomical trees.

Authors:  Kun-Chang Yu; Erik L Ritman; William E Higgins
Journal:  Comput Biol Med       Date:  2007-07-31       Impact factor: 4.589

3.  Algorithm-enabled exploration of image-quality potential of cone-beam CT in image-guided radiation therapy.

Authors:  Xiao Han; Erik Pearson; Charles Pelizzari; Hania Al-Hallaq; Emil Y Sidky; Junguo Bian; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2015-05-28       Impact factor: 3.609

4.  Experimental microcomputed tomography study of the 3D microangioarchitecture of tumors.

Authors:  Nobunao Maehara
Journal:  Eur Radiol       Date:  2002-11-07       Impact factor: 5.315

5.  Artifact reduction in short-scan CBCT by use of optimization-based reconstruction.

Authors:  Zheng Zhang; Xiao Han; Erik Pearson; Charles Pelizzari; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2016-04-05       Impact factor: 3.609

6.  Multimodality imaging of abnormal vascular perfusion and morphology in preclinical 9L gliosarcoma model.

Authors:  Moses M Darpolor; Robert C Molthen; Kathleen M Schmainda
Journal:  PLoS One       Date:  2011-01-31       Impact factor: 3.240

7.  Self-assembled micro-computed tomography for dental education.

Authors:  Che-Wei Liao; Lih-Jyh Fuh; Yen-Wen Shen; Heng-Li Huang; Chih-Wei Kuo; Ming-Tzu Tsai; Jui-Ting Hsu
Journal:  PLoS One       Date:  2018-12-26       Impact factor: 3.240

8.  p66shc siRNA Nanoparticles Ameliorate Chondrocytic Mitochondrial Dysfunction in Osteoarthritis.

Authors:  Hyo Jung Shin; Hyewon Park; Nara Shin; Juhee Shin; Do Hyeong Gwon; Hyeok Hee Kwon; Yuhua Yin; Jeong-Ah Hwang; Jinpyo Hong; Jun Young Heo; Cuk-Seong Kim; Yongbum Joo; Youngmo Kim; Jinhyun Kim; Jaewon Beom; Dong Woon Kim
Journal:  Int J Nanomedicine       Date:  2020-04-08
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.