Literature DB >> 27046218

Artifact reduction in short-scan CBCT by use of optimization-based reconstruction.

Zheng Zhang1, Xiao Han, Erik Pearson, Charles Pelizzari, Emil Y Sidky, Xiaochuan Pan.   

Abstract

Increasing interest in optimization-based reconstruction in research on, and applications of, cone-beam computed tomography (CBCT) exists because it has been shown to have to potential to reduce artifacts observed in reconstructions obtained with the Feldkamp-Davis-Kress (FDK) algorithm (or its variants), which is used extensively for image reconstruction in current CBCT applications. In this work, we carried out a study on optimization-based reconstruction for possible reduction of artifacts in FDK reconstruction specifically from short-scan CBCT data. The investigation includes a set of optimization programs such as the image-total-variation (TV)-constrained data-divergency minimization, data-weighting matrices such as the Parker weighting matrix, and objects of practical interest for demonstrating and assessing the degree of artifact reduction. Results of investigative work reveal that appropriately designed optimization-based reconstruction, including the image-TV-constrained reconstruction, can reduce significant artifacts observed in FDK reconstruction in CBCT with a short-scan configuration.

Entities:  

Mesh:

Year:  2016        PMID: 27046218      PMCID: PMC5496733          DOI: 10.1088/0031-9155/61/9/3387

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  30 in total

1.  Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases.

Authors:  Jonathan S Hott; Vivek R Deshmukh; Jeffrey D Klopfenstein; Volker K H Sonntag; Curtis A Dickman; Robert F Spetzler; Stephen M Papadopoulos
Journal:  Neurosurgery       Date:  2004-05       Impact factor: 4.654

2.  A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory.

Authors:  Xiangyang Tang; Jiang Hsieh; Akira Hagiwara; Roy A Nilsen; Jean-Baptiste Thibault; Evgeny Drapkin
Journal:  Phys Med Biol       Date:  2005-08-02       Impact factor: 3.609

3.  Towards cardiac C-arm computed tomography.

Authors:  Günter Lauritsch; Jan Boese; Lars Wigström; Herbert Kemeth; Rebecca Fahrig
Journal:  IEEE Trans Med Imaging       Date:  2006-07       Impact factor: 10.048

4.  Feldkamp and circle-and-line cone-beam reconstruction for 3D micro-CT of vascular networks.

Authors:  R H Johnson; H Hu; S T Haworth; P S Cho; C A Dawson; J H Linehan
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

5.  Analysis of iterative region-of-interest image reconstruction for x-ray computed tomography.

Authors:  Emil Y Sidky; David N Kraemer; Erin G Roth; Christer Ullberg; Ingrid S Reiser; Xiaochuan Pan
Journal:  J Med Imaging (Bellingham)       Date:  2014-10-03

6.  Optimal short scan convolution reconstruction for fanbeam CT.

Authors:  D L Parker
Journal:  Med Phys       Date:  1982 Mar-Apr       Impact factor: 4.071

7.  Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

Authors:  Xiaochuan Pan; Emil Y Sidky; Michael Vannier
Journal:  Inverse Probl       Date:  2009-01-01       Impact factor: 2.407

8.  Algorithm-enabled exploration of image-quality potential of cone-beam CT in image-guided radiation therapy.

Authors:  Xiao Han; Erik Pearson; Charles Pelizzari; Hania Al-Hallaq; Emil Y Sidky; Junguo Bian; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2015-05-28       Impact factor: 3.609

9.  Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT.

Authors:  Junguo Bian; Jeffrey H Siewerdsen; Xiao Han; Emil Y Sidky; Jerry L Prince; Charles A Pelizzari; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2010-10-20       Impact factor: 3.609

10.  Image-guided radiotherapy via daily online cone-beam CT substantially reduces margin requirements for stereotactic lung radiotherapy.

Authors:  Inga S Grills; Geoffrey Hugo; Larry L Kestin; Ana Paula Galerani; K Kenneth Chao; Jennifer Wloch; Di Yan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-10-29       Impact factor: 7.038

View more
  8 in total

1.  Optimization-Based Image Reconstruction From Low-Count, List-Mode TOF-PET Data.

Authors:  Zheng Zhang; Sean Rose; Jinghan Ye; Amy E Perkins; Buxin Chen; Chien-Min Kao; Emil Y Sidky; Chi-Hua Tung; Xiaochuan Pan
Journal:  IEEE Trans Biomed Eng       Date:  2018-04       Impact factor: 4.538

2.  Reduction of Angularly-Varying-Data Truncation in C-Arm CBCT Imaging.

Authors:  Dan Xia; Yu-Bing Chang; Joe Manak; Adnan H Siddiqui; Zheng Zhang; Buxin Chen; Emil Y Sidky; Xiaochuan Pan
Journal:  Sens Imaging       Date:  2018-03-23

3.  Image reconstruction and scan configurations enabled by optimization-based algorithms in multispectral CT.

Authors:  Buxin Chen; Zheng Zhang; Emil Y Sidky; Dan Xia; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2017-11-02       Impact factor: 3.609

4.  Are metal artefact reduction algorithms effective to correct cone beam CT artefacts arising from the exomass?

Authors:  Amanda Pelegrin Candemil; Benjamin Salmon; Deborah Queiroz Freitas; Glaucia Maria Bovi Ambrosano; Francisco Haiter-Neto; Matheus Lima Oliveira
Journal:  Dentomaxillofac Radiol       Date:  2019-01-28       Impact factor: 2.419

5.  Directional-TV algorithm for image reconstruction from limited-angular-range data.

Authors:  Zheng Zhang; Buxin Chen; Dan Xia; Emil Y Sidky; Xiaochuan Pan
Journal:  Med Image Anal       Date:  2021-03-05       Impact factor: 8.545

6.  Non-convex primal-dual algorithm for image reconstruction in spectral CT.

Authors:  Buxin Chen; Zheng Zhang; Dan Xia; Emil Y Sidky; Xiaochuan Pan
Journal:  Comput Med Imaging Graph       Date:  2020-12-08       Impact factor: 4.790

7.  Detection of preterm birth in electrohysterogram signals based on wavelet transform and stacked sparse autoencoder.

Authors:  Lili Chen; Yaru Hao; Xue Hu
Journal:  PLoS One       Date:  2019-04-16       Impact factor: 3.240

8.  A cone-beam X-ray computed tomography data collection designed for machine learning.

Authors:  Henri Der Sarkissian; Felix Lucka; Maureen van Eijnatten; Giulia Colacicco; Sophia Bethany Coban; Kees Joost Batenburg
Journal:  Sci Data       Date:  2019-10-22       Impact factor: 6.444

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.