Literature DB >> 29192888

Low-Dose CBCT Reconstruction Using Hessian Schatten Penalties.

Liang Liu, Xinxin Li, Kai Xiang, Jing Wang, Shan Tan.   

Abstract

Cone-beam computed tomography (CBCT) has been widely used in radiation therapy. For accurate patient setup and treatment target localization, it is important to obtain high-quality reconstruction images. The total variation (TV) penalty has shown the state-of-the-art performance in suppressing noise and preserving edges for statistical iterative image reconstruction, but it sometimes leads to the so-called staircase effect. In this paper, we proposed to use a new family of penalties-the Hessian Schatten (HS) penalties-for the CBCT reconstruction. Consisting of the second-order derivatives, the HS penalties are able to reflect the smooth intensity transitions of the underlying image without introducing the staircase effect. We discussed and compared the behaviors of several convex HS penalties with orders 1, 2, and for CBCT reconstruction. We used the majorization-minimization approach with a primal-dual formulation for the corresponding optimization problem. Experiments on two digital phantoms and two physical phantoms demonstrated the proposed penalty family's outstanding performance over TV in suppressing the staircase effect, and the HS penalty with order 1 had the best performance among the HS penalties tested.

Entities:  

Mesh:

Year:  2017        PMID: 29192888      PMCID: PMC5744602          DOI: 10.1109/TMI.2017.2766185

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  30 in total

1.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

2.  Noise reduction and convergence of Bayesian algorithms with blobs based on the Huber function and median root prior.

Authors:  W Chlewicki; F Hermansen; S B Hansen
Journal:  Phys Med Biol       Date:  2004-10-21       Impact factor: 3.609

3.  Penalized weighted least-squares image reconstruction for positron emission tomography.

Authors:  J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

4.  An experimental study on the noise properties of x-ray CT sinogram data in Radon space.

Authors:  Jing Wang; Hongbing Lu; Zhengrong Liang; Daria Eremina; Guangxiang Zhang; Su Wang; John Chen; James Manzione
Journal:  Phys Med Biol       Date:  2008-06-03       Impact factor: 3.609

5.  Improved total variation-based CT image reconstruction applied to clinical data.

Authors:  Ludwig Ritschl; Frank Bergner; Christof Fleischmann; Marc Kachelriess
Journal:  Phys Med Biol       Date:  2011-02-16       Impact factor: 3.609

6.  Hessian Schatten-norm regularization for linear inverse problems.

Authors:  Stamatios Lefkimmiatis; John Paul Ward; Michael Unser
Journal:  IEEE Trans Image Process       Date:  2013-01-04       Impact factor: 10.856

7.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

8.  Algorithm-enabled exploration of image-quality potential of cone-beam CT in image-guided radiation therapy.

Authors:  Xiao Han; Erik Pearson; Charles Pelizzari; Hania Al-Hallaq; Emil Y Sidky; Junguo Bian; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2015-05-28       Impact factor: 3.609

9.  Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction.

Authors:  Yan Liu; Jianhua Ma; Yi Fan; Zhengrong Liang
Journal:  Phys Med Biol       Date:  2012-11-15       Impact factor: 3.609

10.  Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms.

Authors:  Jie Tang; Brian E Nett; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2009-09-09       Impact factor: 3.609

View more
  3 in total

1.  Low-dose Cone-Beam Computed Tomography Reconstruction through a fast Three-Dimensional Compressed Sensing Method Based on the Three-Dimensional Pseudo-polar Fourier Transform.

Authors:  N Teyfouri; Hossein Rabbani; I Jabbari
Journal:  J Med Signals Sens       Date:  2021-12-28

2.  Low Dose CT Image Reconstruction Based on Structure Tensor Total Variation Using Accelerated Fast Iterative Shrinkage Thresholding Algorithm.

Authors:  Junfeng Wu; Xiaofeng Wang; Xuanqin Mou; Yang Chen; Shuguang Liu
Journal:  Sensors (Basel)       Date:  2020-03-16       Impact factor: 3.576

3.  Experiences with image quality and radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in pediatric extremity trauma.

Authors:  Sebastian Tschauner; Robert Marterer; Eszter Nagy; Georg Singer; Michael Riccabona; Erich Sorantin
Journal:  Skeletal Radiol       Date:  2020-06-14       Impact factor: 2.199

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.