Literature DB >> 25947898

Accuracy of combined anteversion in image-free navigated total hip arthroplasty: stem-first or cup-first technique?

Shigeo Fukunishi1, Shoji Nishio2, Yuki Fujihara2, Shohei Okahisa2, Yu Takeda2, Tomokazu Fukui2, Shinichi Yoshiya2.   

Abstract

PURPOSE: In total hip arthroplasty (THA), combined anteversion (CA) is used as a parameter for assessment of overall prosthetic alignment. The purpose of this study was to comparatively examine the CA value in patients who underwent primary THA using the image-free navigation system either with a cup-first or stem-first technique.
METHODS: Eighty-three hips undergoing primary THA using the OrthoPilot® image-free navigation system (B. Braun-Aesculap, Tuttlingen, Germany) were included in this study. The patient population was divided into two groups depending on the procedure used: cup-first technique and stem-first technique. In the cup-first group, inclination and anteversion (AV) angles were targeted at 35-45° and 15-25°, respectively, while stem antetorsion (AT) was determined for each patient based on the amount of individual native femoral AT angle. In the stem-first group, the femur was prepared first with the target angle corresponding to the native femoral AT and the cup AV was decided considering the CA calculated with Widmer's formula (aiming at the optimal Widmer's CA of 37.3°).
RESULTS: Better consistency in Widmer's CA values was attained in the stem-first group as indicated by the smaller SD values. In the assessment of overall alignment, Widmer's CA values were within the satisfactory range (37 ± 5°) in 41.9 and 92.3 % of the subjects in the cup-first group and the stem-first group, respectively.
CONCLUSIONS: The stem-first technique with image-free navigated THA could effectively achieve accurate and consistent control of the CA value and thus is expected to improve the surgical outcome.

Entities:  

Keywords:  Combined anteversion; Navigation; Stem first; Total hip arthroplasty

Mesh:

Year:  2015        PMID: 25947898     DOI: 10.1007/s00264-015-2784-9

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  27 in total

1.  3D CT analysis of combined cup and stem anteversion in cases of cup navigation in hip arthroplasty.

Authors:  Georgi I Wassilew; Carsten Perka; Christian Koenig; Viktor Janz; Patrick Asbach; Olaf Hasart
Journal:  Orthopedics       Date:  2010-10       Impact factor: 1.390

2.  Use of image-free navigation in determination of acetabular cup orientation: analysis of factors affecting precision.

Authors:  Tomokazu Fukui; Shigeo Fukunishi; Shoji Nishio; Nao Shibanuma; Shinichi Yoshiya
Journal:  Orthopedics       Date:  2010-10       Impact factor: 1.390

3.  The use of combined anteversion in total hip arthroplasty for patients with developmental dysplasia of the hip.

Authors:  Jingwei Zhang; Liao Wang; Yuanqing Mao; Huiwu Li; Huifeng Ding; Zhenan Zhu
Journal:  J Arthroplasty       Date:  2013-09-09       Impact factor: 4.757

4.  Total hip arthroplasty through a minimal posterior approach using imageless computer-assisted hip navigation.

Authors:  Richard L Wixson; Margot A MacDonald
Journal:  J Arthroplasty       Date:  2005-10       Impact factor: 4.757

5.  A comparison of alternative methods of measuring femoral anteversion.

Authors:  N Sugano; P C Noble; E Kamaric
Journal:  J Comput Assist Tomogr       Date:  1998 Jul-Aug       Impact factor: 1.826

6.  Three-dimensional morphology of the proximal femur.

Authors:  O Husmann; P J Rubin; P F Leyvraz; B de Roguin; J N Argenson
Journal:  J Arthroplasty       Date:  1997-06       Impact factor: 4.757

7.  The definition and measurement of acetabular orientation.

Authors:  D W Murray
Journal:  J Bone Joint Surg Br       Date:  1993-03

8.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

9.  Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis.

Authors:  B M Jolles; P Zangger; P-F Leyvraz
Journal:  J Arthroplasty       Date:  2002-04       Impact factor: 4.757

10.  A comparison of surgeon estimation and computed tomographic measurement of femoral component anteversion in cementless total hip arthroplasty.

Authors:  Lawrence D Dorr; Zhinian Wan; Aamer Malik; Jinjun Zhu; Manish Dastane; Prashant Deshmane
Journal:  J Bone Joint Surg Am       Date:  2009-11       Impact factor: 5.284

View more
  8 in total

1.  Effect of improved navigation performance on the accuracy of implant placement in total hip arthroplasty with a CT-based navigation system.

Authors:  Ichiro Nakahara; Takayuki Kyo; Yasuo Kuroda; Hidenobu Miki
Journal:  J Artif Organs       Date:  2018-04-02       Impact factor: 1.731

2.  New combined anteversion technique in hybrid THA: cup-first procedure with CT-based navigation.

Authors:  Yoshinobu Masumoto; Shigeo Fukunishi; Tomokazu Fukui; Shinichi Yoshiya; Shoji Nishio; Yuki Fujihara; Shohei Okahisa; Taishi Okada; Makoto Kanto; Ariha Goshi; Futoshi Morio; Yu Takeda
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-11-08

3.  Image-Less THA Cup Navigation in Clinical Routine Setup: Individual Adjustments, Accuracy, Precision, and Robustness.

Authors:  Corinne A Zurmühle; Benjamin Zickmantel; Matthias Christen; Bernhard Christen; Guoyan Zheng; Joseph M Schwab; Moritz Tannast; Simon D Steppacher
Journal:  Medicina (Kaunas)       Date:  2022-06-20       Impact factor: 2.948

4.  Accuracy of a novel accelerometer-based navigation (Naviswiss) for total hip arthroplasty in the supine position.

Authors:  Masahiro Hasegawa; Yohei Naito; Shine Tone; Akihiro Sudo
Journal:  BMC Musculoskelet Disord       Date:  2022-06-04       Impact factor: 2.562

5.  Measurement of operative femoral anteversion during cementless total hip arthroplasty and influencing factors for using neck-adjustable femoral stem.

Authors:  Jingyang Sun; Bohan Zhang; Lei Geng; Qingyuan Zheng; Juncheng Li; Wenzhe Cao; Ming Ni; Guoqiang Zhang
Journal:  J Orthop Surg Res       Date:  2021-05-31       Impact factor: 2.359

6.  What do we get from navigation in primary THA?

Authors:  Lisa Renner; Viktor Janz; Carsten Perka; Georgi I Wassilew
Journal:  EFORT Open Rev       Date:  2017-03-13

7.  Clinical efficacy of orthopilot navigation system versus conventional manual of total hip arthroplasty: A systematic review and meta-analysis.

Authors:  Jianguo Jia; Qun Zhao; Pei Lu; Guiyong Fan; Hao Chen; Chaoqun Liu; Jinlian Liu; Sheng Chen; Zhengshuai Jin
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

8.  A simple angle-measuring instrument for measuring cemented stem anteversion during total hip arthroplasty.

Authors:  Ryo Mitsutake; Hiromasa Tanino; Yasuhiro Nishida; Masaru Higa; Hiroshi Ito
Journal:  BMC Musculoskelet Disord       Date:  2020-02-19       Impact factor: 2.362

  8 in total