A comparison of alternative methods of measuring femoral anteversion.

N Sugano1, P C Noble, E Kamaric.   

Abstract

PURPOSE: Although CT scans are widely believed to provide the most accurate measurements of femoral anteversion, any estimate of the anteversion of the femur depends on the accuracy of the calculated axis of the femoral neck. We devised a method to measure the anteversion of the femur precisely using a 3D femoral computer model reconstructed from digitized femoral contours. Using this method, we compared the accuracy of three popular methods of anteversion measurement based on CT scans.
METHOD: The three popular CT methods were as follows: (a) the classic method of Weiner et al., based on a single CT image; (b) the method of Reikerås et al., in which the neck axis is defined by two superimposed images of the femoral head and neck; and (c) the method of Murphy et al., utilizing centroids of the head and the medullary canal. The accuracy of the single slice method was also examined using slices taken at four different neck slice levels within the proximal femur. CT scans of 30 femora were obtained using a helical CT scanner and reconstructed using custom software.
RESULTS: Based on the 3D model, the true anteversion of the femora averaged 19.8 +/- 9.3 degrees (SD). Using the method of Weiner et al., the anteversion of the femora was underestimated by an average of 6.4 degrees (predicted value 13.4 +/- 10.4 degrees). Conversely, Murphy et al.'s method overestimated anteversion by an average of 6.3 degrees with an average value of 26.0 +/- 9.1 degrees. The difference between the true anteversion and the values predicted by both of these methods was statistically significant (p < 0.001). The average anteversion measured according to the method of Reikerås et al. was 17.8 +/- 8.9 degrees, 2.0 degrees less than the true anteversion of the sample (p < 0.005). Anteversion angles predicted from a slice just below the inferior edge of the head averaged 18.3 +/- 9.5 degrees, only 1.5-3.1 degrees less than the true anteversion of the femur (p = 0.14).
CONCLUSION: The single slice CT method has sufficient accuracy for use, provided the slice is taken just below the femoral head. In cases with a femoral head deformity or a valgus neck or where difficulty is encountered in positioning the patient, 3D reconstruction appears essential for accurate measurement of anteversion.

Entities:  

Mesh:

Year:  1998        PMID: 9676454     DOI: 10.1097/00004728-199807000-00019

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  68 in total

1.  Comparison of femoral morphology and bone mineral density between femoral neck fractures and trochanteric fractures.

Authors:  Yuki Maeda; Nobuhiko Sugano; Masanobu Saito; Kazuo Yonenobu
Journal:  Clin Orthop Relat Res       Date:  2010-08-20       Impact factor: 4.176

2.  Assessment of two-dimensional (2D) and three-dimensional (3D) lower limb measurements in adults: Comparison of micro-dose and low-dose biplanar radiographs.

Authors:  Andrea B Rosskopf; Christian W A Pfirrmann; Florian M Buck
Journal:  Eur Radiol       Date:  2016-01-06       Impact factor: 5.315

3.  Measuring physiological and pathological femoral anteversion using a biplanar low-dose X-ray system: validity, reliability, and discriminative ability in cerebral palsy.

Authors:  Matthias Thépaut; Sylvain Brochard; Julien Leboucher; Mathieu Lempereur; Eric Stindel; Valentin Tissot; Bhushan S Borotikar
Journal:  Skeletal Radiol       Date:  2015-11-27       Impact factor: 2.199

4.  Three-dimensional in vivo difference between native acetabular version and acetabular component version influences iliopsoas impingement after total hip arthroplasty.

Authors:  Kwan Kyu Park; Tsung-Yuan Tsai; Dimitris Dimitriou; Young-Min Kwon
Journal:  Int Orthop       Date:  2015-11-27       Impact factor: 3.075

5.  Combined anteversion technique reduced the dislocation in cementless total hip arthroplasty.

Authors:  Yasuharu Nakashima; Masanobu Hirata; Mio Akiyama; Takashi Itokawa; Takuaki Yamamoto; Goro Motomura; Masanobu Ohishi; Satoshi Hamai; Yukihide Iwamoto
Journal:  Int Orthop       Date:  2013-09-13       Impact factor: 3.075

Review 6.  [Value of radiographic examination of the knee joint for the orthopedic surgeon].

Authors:  M Pietsch; S Hofmann
Journal:  Radiologe       Date:  2006-01       Impact factor: 0.635

7.  3D femoral neck anteversion measurements based on the posterior femoral plane in ORTHODOC system.

Authors:  Yeon Soo Lee; Seung Hoon Oh; Jong Keun Seon; Eun Kyoo Song; Taek Rim Yoon
Journal:  Med Biol Eng Comput       Date:  2006-09-29       Impact factor: 2.602

8.  A local reference frame for describing the proximal human femur: application in clinical settings.

Authors:  Milad Masjedi; Charison Tay; Simon J Harris; Justin P Cobb
Journal:  Skeletal Radiol       Date:  2013-12-18       Impact factor: 2.199

9.  An evaluation of CT-scan to locate the femoral head centre and its implication for hip surgeons.

Authors:  Anthony Viste; Franck Trouillet; Rodolphe Testa; Laurence Chèze; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Surg Radiol Anat       Date:  2013-07-24       Impact factor: 1.246

10.  Influence of acetabular and femoral version on fractures of the femoral neck.

Authors:  A Frost; G Pavlou; P J Richards; J Belcher; V Jasani
Journal:  Clin Orthop Relat Res       Date:  2009-12-05       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.