Continuous noninvasive arterial pressure measurement using the volume clamp method: an evaluation of the CNAP device in intensive care unit patients.

Julia Y Wagner1,2, Ileana Negulescu3, Miriam Schöfthaler3, Alexander Hapfelmeier4, Agnes S Meidert3, Wolfgang Huber3, Roland M Schmid3, Bernd Saugel5,6.   

Abstract

The CNAP system allows continuous noninvasive arterial pressure measurement based on the volume clamp method using a finger cuff. We aimed to evaluate the agreement between arterial pressure measurements noninvasively obtained using the CNAP device and arterial catheter-derived arterial pressure measurements in intensive care unit patients. In 55 intensive care unit patients, we simultaneously recorded arterial pressure values obtained by an arterial catheter placed in the abdominal aorta through the femoral artery (criterion standard) and arterial pressure values determined noninvasively using CNAP. We performed Bland-Altman analysis and calculated the percentage error. The mean difference (±standard deviation, 95% limits of agreement, percentage error) between noninvasive (CNAP) and invasively assessed arterial pressure was for mean arterial pressure +1 mmHg (±9 mmHg, -16 to +19 mmHg, 22%), for systolic arterial pressure -10 mmHg (±16 mmHg, -42 to +21 mmHg, 27%), and for diastolic arterial pressure +7 mmHg (±9 mmHg, -10 to +24 mmHg, 28%). Our results indicate a reasonable accuracy and precision for the determination of mean and diastolic arterial pressure by noninvasive continuous arterial pressure measurements using the volume clamp method compared with the criterion standard (invasive arterial catheter). Systolic arterial pressure is determined less accurately and precisely.

Entities:  

Keywords:  Blood pressure; Critical care; Hemodynamic monitoring; Photoplethysmography; Vascular unloading technology

Mesh:

Year:  2015        PMID: 25726179     DOI: 10.1007/s10877-015-9670-2

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  19 in total

1.  Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults.

Authors:  Eoin O'Brien; Thomas Pickering; Roland Asmar; Martin Myers; Gianfranco Parati; Jan Staessen; Thomas Mengden; Yutaka Imai; Bernard Waeber; Paolo Palatini; William Gerin
Journal:  Blood Press Monit       Date:  2002-02       Impact factor: 1.444

2.  Clinical validation of a continuous non-invasive haemodynamic monitor (CNAP™ 500) during general anaesthesia.

Authors:  R Hahn; H Rinösl; M Neuner; S C Kettner
Journal:  Br J Anaesth       Date:  2012-02-03       Impact factor: 9.166

3.  The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patients.

Authors:  Bernd Saugel; Florian Fassio; Alexander Hapfelmeier; Agnes S Meidert; Roland M Schmid; Wolfgang Huber
Journal:  Intensive Care Med       Date:  2012-06-29       Impact factor: 17.440

4.  A comparison of a continuous noninvasive arterial pressure (CNAP™) monitor with an invasive arterial blood pressure monitor in the cardiac surgical ICU.

Authors:  A M Jagadeesh; Naveen G Singh; Subramanyam Mahankali
Journal:  Ann Card Anaesth       Date:  2012 Jul-Sep

5.  Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops.

Authors:  J Fortin; W Marte; R Grüllenberger; A Hacker; W Habenbacher; A Heller; Ch Wagner; P Wach; F Skrabal
Journal:  Comput Biol Med       Date:  2006-02-17       Impact factor: 4.589

6.  Radial artery applanation tonometry for continuous non-invasive arterial pressure monitoring in intensive care unit patients: comparison with invasively assessed radial arterial pressure.

Authors:  A S Meidert; W Huber; J N Müller; M Schöfthaler; A Hapfelmeier; N Langwieser; J Y Wagner; F Eyer; R M Schmid; B Saugel
Journal:  Br J Anaesth       Date:  2013-12-18       Impact factor: 9.166

7.  Guidelines for the prevention of intravascular catheter-related infections.

Authors:  Naomi P O'Grady; Mary Alexander; Lillian A Burns; E Patchen Dellinger; Jeffrey Garland; Stephen O Heard; Pamela A Lipsett; Henry Masur; Leonard A Mermel; Michele L Pearson; Issam I Raad; Adrienne G Randolph; Mark E Rupp; Sanjay Saint
Journal:  Am J Infect Control       Date:  2011-05       Impact factor: 2.918

8.  Are we ready for the age of non-invasive haemodynamic monitoring?

Authors:  B Saugel; D A Reuter
Journal:  Br J Anaesth       Date:  2014-05-31       Impact factor: 9.166

9.  Indications and complications of arterial catheter use in surgical or medical intensive care units: analysis of 4932 patients.

Authors:  E E Frezza; H Mezghebe
Journal:  Am Surg       Date:  1998-02       Impact factor: 0.688

10.  Noninvasive continuous arterial blood pressure monitoring with Nexfin®.

Authors:  Jerson R Martina; Berend E Westerhof; Jeroen van Goudoever; Edouard M F H de Beaumont; Jasper Truijen; Yu-Sok Kim; Rogier V Immink; Dorothea A Jöbsis; Markus W Hollmann; Jaap R Lahpor; Bas A J M de Mol; Johannes J van Lieshout
Journal:  Anesthesiology       Date:  2012-05       Impact factor: 7.892

View more
  13 in total

Review 1.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

2.  Comparison of Invasive and Noninvasive Blood Pressure Measurements for Assessing Signal Complexity and Surgical Risk in Cardiac Surgical Patients.

Authors:  Lauren E Gibson; Teresa S Henriques; Madalena D Costa; Roger B Davis; Murray A Mittleman; Pooja Mathur; Balachundhar Subramaniam
Journal:  Anesth Analg       Date:  2020-06       Impact factor: 5.108

3.  The future of intraoperative blood pressure management.

Authors:  Frederic Michard; Ngai Liu; Andrea Kurz
Journal:  J Clin Monit Comput       Date:  2017-02-07       Impact factor: 2.502

4.  Non-invasive monitoring using photoplethysmography technology.

Authors:  Keisuke Tomita; Taka-Aki Nakada; Taku Oshima; Takehiko Oami; Tuerxun Aizimu; Shigeto Oda
Journal:  J Clin Monit Comput       Date:  2018-10-04       Impact factor: 2.502

5.  A novel non-invasive blood pressure waveform measuring system compared to Millar applanation tonometry.

Authors:  Sándor Földi; Tamás Horváth; Flóra Zieger; Péter Sótonyi; György Cserey
Journal:  J Clin Monit Comput       Date:  2017-10-04       Impact factor: 2.502

Review 6.  [S3 guidelines on intensive medical care of cardiac surgery patients : Hemodynamic monitoring and cardiovascular system-an update].

Authors:  M Habicher; T Zajonz; M Heringlake; A Böning; S Treskatsch; U Schirmer; A Markewitz; M Sander
Journal:  Anaesthesist       Date:  2018-05       Impact factor: 1.041

7.  Cardiovascular dynamics during peroral endoscopic myotomy for esophageal achalasia: a prospective observational study using non-invasive finger cuff-derived pulse wave analysis.

Authors:  Bernd Saugel; Christina Vokuhl; Hans O Pinnschmidt; Thomas Rösch; Martin Petzoldt; Benjamin Löser
Journal:  J Clin Monit Comput       Date:  2020-06-05       Impact factor: 2.502

8.  A comparison of volume clamp method-based continuous noninvasive cardiac output (CNCO) measurement versus intermittent pulmonary artery thermodilution in postoperative cardiothoracic surgery patients.

Authors:  Julia Y Wagner; Annmarie Körner; Leonie Schulte-Uentrop; Mathias Kubik; Hermann Reichenspurner; Stefan Kluge; Daniel A Reuter; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2017-05-24       Impact factor: 2.502

9.  Continuous noninvasive cardiac output determination using the CNAP system: evaluation of a cardiac output algorithm for the analysis of volume clamp method-derived pulse contour.

Authors:  Julia Y Wagner; Julian Grond; Jürgen Fortin; Ileana Negulescu; Miriam Schöfthaler; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2015-07-31       Impact factor: 2.502

10.  Investigating the ability of non-invasive measures of cardiac output to detect a reduction in blood volume resulting from venesection in spontaneously breathing subjects.

Authors:  Benjamin Mothibe Bussmann; William Hulme; Andrew Tang; Tim Harris
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2018-12-04       Impact factor: 2.953

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.