Literature DB >> 30399022

Comparison of Invasive and Noninvasive Blood Pressure Measurements for Assessing Signal Complexity and Surgical Risk in Cardiac Surgical Patients.

Lauren E Gibson1, Teresa S Henriques1,2, Madalena D Costa2, Roger B Davis3, Murray A Mittleman4, Pooja Mathur1, Balachundhar Subramaniam1.   

Abstract

BACKGROUND: Continuous arterial blood pressure (ABP) is typically recorded by placement of an intraarterial catheter. Recently, noninvasive ABP monitors have been shown to be comparable in accuracy to invasive measurements. In a previous study, we showed that the fluctuations in beat-to-beat ABP measurements were not random variations but had a complex dynamical structure, and that ABP dynamical complexity was inversely associated with surgical risk estimated using the Society of Thoracic Surgeons (STS) index. Dynamical complexity is a mathematical construct that reflects the capacity of a physiological system to adapt to stimuli. The objectives of present study were to: (1) determine whether noninvasive beat-to-beat ABP measurements also exhibit a complex temporal structure; (2) compare the complexity of noninvasive versus invasive ABP time series; and (3) quantify the relationship between the complexity of noninvasive ABP time series and the STS risk scores.
METHODS: Fifteen adult patients undergoing coronary artery bypass graft, valve, or combined coronary artery bypass graft/valve surgery were enrolled in this observational study. Preoperative ABP waveforms were simultaneously recorded for ≥15 minutes using a radial artery catheter (invasive) and a continuous noninvasive arterial pressure monitor. Beat-to-beat systolic blood pressure (SBP), diastolic blood pressure (DBP), pulse pressure (PP), and mean arterial pressure (MAP) time series were extracted from the continuous waveforms. Complexity was assessed using the multiscale entropy method. The Wilcoxon signed-rank test was used to compare the mean ranks of indices derived from invasive versus noninvasive ABP time series. Spearman correlation coefficients were used to quantify the relationship between invasive and noninvasive indices. Linear regression analysis was used to quantify the association between each of the complexity indices and the STS risk scores.
RESULTS: Beat-to-beat fluctuations in noninvasive ABP measurements were not random but complex; however, their degree of complexity was lower than that of fluctuations in invasively obtained ABP signals (SBP: 7.05 vs 8.66, P < .001; DBP: 7.40 vs 8.41, P < .001; PP: 6.83 vs 8.82, P < .001; and MAP: 7.17 vs 8.68, P < .005). Invasive and noninvasive indices for MSEΣ·slope showed good correlation (rs) (0.53 for SBP, 0.79 for DBP, 0.42 for PP, 0.60 for MAP). The complexity of noninvasive ABP time series (-0.70 [-1.28 to -0.11]; P = .023 for DBP), like that of invasive time series (-0.94 [-1.52 to -0.35]; P = .004 for DBP), was inversely associated with estimated surgical risk in patients undergoing cardiovascular operations.
CONCLUSIONS: Our results support the use of noninvasive ABP monitoring in computations of complexity-based indices that correlate with estimated surgical risk.

Entities:  

Mesh:

Year:  2020        PMID: 30399022      PMCID: PMC7598931          DOI: 10.1213/ANE.0000000000003894

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  17 in total

1.  Inaccuracy of four coronary surgery risk-adjusted models to predict mortality in individual patients.

Authors:  P Pinna-Pintor; M Bobbio; S Colangelo; F Veglia; M Giammaria; D Cuni; F Maisano; O Alfieri
Journal:  Eur J Cardiothorac Surg       Date:  2002-02       Impact factor: 4.191

2.  Multiscale entropy analysis of complex physiologic time series.

Authors:  Madalena Costa; Ary L Goldberger; C-K Peng
Journal:  Phys Rev Lett       Date:  2002-07-19       Impact factor: 9.161

3.  Continuous noninvasive arterial pressure measurement using the volume clamp method: an evaluation of the CNAP device in intensive care unit patients.

Authors:  Julia Y Wagner; Ileana Negulescu; Miriam Schöfthaler; Alexander Hapfelmeier; Agnes S Meidert; Wolfgang Huber; Roland M Schmid; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2015-03-01       Impact factor: 2.502

Review 4.  Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis.

Authors:  Sang-Hyun Kim; Marc Lilot; Kulraj S Sidhu; Joseph Rinehart; Zhaoxia Yu; Cecilia Canales; Maxime Cannesson
Journal:  Anesthesiology       Date:  2014-05       Impact factor: 7.892

5.  Blood pressure variability: can nonlinear dynamics enhance risk assessment during cardiovascular surgery?

Authors:  Balachundhar Subramaniam; Kamal R Khabbaz; Thomas Heldt; Adam B Lerner; Murray A Mittleman; Roger B Davis; Ary L Goldberger; Madalena D Costa
Journal:  J Cardiothorac Vasc Anesth       Date:  2014-02-06       Impact factor: 2.628

6.  First publications from the Society of Thoracic Surgeons National Database.

Authors:  R P Anderson
Journal:  Ann Thorac Surg       Date:  1994-01       Impact factor: 4.330

7.  Changes over time in risk profiles of patients who undergo coronary artery bypass graft surgery: the Veterans Affairs Surgical Quality Improvement Program (VASQIP).

Authors:  Lorraine D Cornwell; Shuab Omer; Todd Rosengart; William L Holman; Faisal G Bakaeen
Journal:  JAMA Surg       Date:  2015-04       Impact factor: 14.766

8.  Reliability of risk algorithms in predicting early and late operative outcomes in high-risk patients undergoing aortic valve replacement.

Authors:  Todd M Dewey; David Brown; William H Ryan; Morley A Herbert; Syma L Prince; Michael J Mack
Journal:  J Thorac Cardiovasc Surg       Date:  2007-11-26       Impact factor: 5.209

9.  Evaluation of continuous non-invasive arterial pressure monitoring during induction of general anaesthesia in patients undergoing cardiac surgery.

Authors:  G Anil Kumar; A M Jagadeesh; Naveen G Singh; S R Prasad
Journal:  Indian J Anaesth       Date:  2015-01

Review 10.  Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine.

Authors:  Bernd Scheer; Azriel Perel; Ulrich J Pfeiffer
Journal:  Crit Care       Date:  2002-04-18       Impact factor: 9.097

View more
  5 in total

1.  Predictive Capacity of Beat-to-Beat Blood Pressure Variability for Cardioautonomic and Vascular Dysfunction in Early Metabolic Challenge.

Authors:  Souha A Fares; Nour-Mounira Z Bakkar; Ahmed F El-Yazbi
Journal:  Front Pharmacol       Date:  2022-06-24       Impact factor: 5.988

2.  Preoperative Blood Pressure Complexity Indices as a Marker for Frailty in Patients Undergoing Cardiac Surgery.

Authors:  Valluvan Rangasamy; Teresa S Henriques; Xinling Xu; Balachundhar Subramaniam
Journal:  J Cardiothorac Vasc Anesth       Date:  2019-09-30       Impact factor: 2.628

3.  Non-Invasive Continuous Blood-Pressure Monitoring Models Based on Photoplethysmography and Electrocardiography.

Authors:  Haiyan Wu; Zhong Ji; Mengze Li
Journal:  Sensors (Basel)       Date:  2019-12-15       Impact factor: 3.576

4.  Multiscale Analysis of Runoff Complexity in the Yanhe Watershed.

Authors:  Xintong Liu; Hongrui Zhao
Journal:  Entropy (Basel)       Date:  2022-08-07       Impact factor: 2.738

5.  Blood Pressure Complexity Discriminates Pathological Beat-to-Beat Variability as a Marker of Vascular Aging.

Authors:  Yun-Kai Lee; Sara Mazzucco; Peter M Rothwell; Stephen J Payne; Alastair J S Webb
Journal:  J Am Heart Assoc       Date:  2022-01-19       Impact factor: 6.106

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.