Noninvasive continuous arterial blood pressure monitoring with Nexfin®.

Jerson R Martina1, Berend E Westerhof, Jeroen van Goudoever, Edouard M F H de Beaumont, Jasper Truijen, Yu-Sok Kim, Rogier V Immink, Dorothea A Jöbsis, Markus W Hollmann, Jaap R Lahpor, Bas A J M de Mol, Johannes J van Lieshout.   

Abstract

BACKGROUND: If invasive measurement of arterial blood pressure is not warranted, finger cuff technology can provide continuous and noninvasive monitoring. Finger and radial artery pressures differ; Nexfin® (BMEYE, Amsterdam, The Netherlands) measures finger arterial pressure and uses physiologic reconstruction methodologies to obtain values comparable to invasive pressures.
METHODS: Intra-arterial pressure (IAP) and noninvasive Nexfin arterial pressure (NAP) were measured in cardiothoracic surgery patients, because invasive pressures are available. NAP-IAP differences were analyzed during 30 min. Tracking was quantified by within-subject precision (SD of individual NAP-IAP differences) and correlation coefficients. The ranges of pressure change were quantified by within-subject variability (SD of individual averages of NAP and IAP). Accuracy and precision were expressed as group average ± SD of the differences and considered acceptable when smaller than 5 ± 8 mmHg, the Association for the Advancement of Medical Instrumentation criteria.
RESULTS: NAP and IAP were obtained in 50 (34-83 yr, 40 men) patients. For systolic, diastolic, mean arterial, and pulse pressure, median (25-75 percentiles) correlation coefficients were 0.96 (0.91-0.98), 0.93 (0.87-0.96), 0.96 (0.90-0.97), and 0.94 (0.85-0.98), respectively. Within-subject precisions were 4 ± 2, 3 ± 1, 3 ± 2, and 3 ± 2 mmHg, and within-subject variations 13 ± 6, 6 ± 3, 9 ± 4, and 7 ± 4 mmHg, indicating precision over a wide range of pressures. Group average ± SD of the NAP-IAP differences were -1 ± 7, 3 ± 6, 2 ± 6, and -3 ± 4 mmHg, meeting criteria. Differences were not related to mean arterial pressure or heart rate.
CONCLUSION: Arterial blood pressure can be measured noninvasively and continuously using physiologic pressure reconstruction. Changes in pressure can be followed and values are comparable to invasive monitoring.

Entities:  

Mesh:

Year:  2012        PMID: 22415387     DOI: 10.1097/ALN.0b013e31824f94ed

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  73 in total

Review 1.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

2.  Interactions between beta-2 adrenoceptor gene variation, cardiovascular control and dietary sodium in healthy young adults.

Authors:  John H Eisenach; Darrell R Schroeder; Emily S Pavey; Alan R Penheiter; Jean N Knutson; Stephen T Turner; Michael J Joyner
Journal:  J Physiol       Date:  2014-09-25       Impact factor: 5.182

3.  Continuous noninvasive arterial pressure measurement using the volume clamp method: an evaluation of the CNAP device in intensive care unit patients.

Authors:  Julia Y Wagner; Ileana Negulescu; Miriam Schöfthaler; Alexander Hapfelmeier; Agnes S Meidert; Wolfgang Huber; Roland M Schmid; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2015-03-01       Impact factor: 2.502

4.  [Principles and pitfalls of arterial blood pressure measurement].

Authors:  A S Meidert; J Briegel; B Saugel
Journal:  Anaesthesist       Date:  2019-09       Impact factor: 1.041

5.  The future of intraoperative blood pressure management.

Authors:  Frederic Michard; Ngai Liu; Andrea Kurz
Journal:  J Clin Monit Comput       Date:  2017-02-07       Impact factor: 2.502

Review 6.  Non-invasive continuous blood pressure monitoring: a review of current applications.

Authors:  Elena Chung; Guo Chen; Brenton Alexander; Maxime Cannesson
Journal:  Front Med       Date:  2013-01-23       Impact factor: 4.592

Review 7.  Orthostatic Circulatory Disorders: From Nosology to Nuts and Bolts.

Authors:  Michael Gutkin; Julian M Stewart
Journal:  Am J Hypertens       Date:  2016-04-01       Impact factor: 2.689

8.  A novel non-invasive blood pressure waveform measuring system compared to Millar applanation tonometry.

Authors:  Sándor Földi; Tamás Horváth; Flóra Zieger; Péter Sótonyi; György Cserey
Journal:  J Clin Monit Comput       Date:  2017-10-04       Impact factor: 2.502

9.  Non-invasive arterial pressure monitoring revisited.

Authors:  Frederic Michard; Daniel I Sessler; Bernd Saugel
Journal:  Intensive Care Med       Date:  2018-03-07       Impact factor: 17.440

Review 10.  Accuracy of non-invasive and minimally invasive hemodynamic monitoring: where do we stand?

Authors:  Issa Pour-Ghaz; Theodore Manolukas; Nathalie Foray; Joel Raja; Aranyak Rawal; Uzoma N Ibebuogu; Rami N Khouzam
Journal:  Ann Transl Med       Date:  2019-09