| Literature DB >> 25694925 |
William F Lavelle1, Ashish Ranade2, Amer F Samdani3, John P Gaughan4, Linda P D'Andrea5, Randal R Betz6.
Abstract
BACKGROUND: Pedicle screws are used increasingly in spine surgery. Concerns of complications associated with screw breach necessitates accurate pedicle screw placement. Postoperative CT imaging helps to detect screw malposition and assess its severity. However, accuracy is dependent on the reading of the CT scans. Inter- and intra-observer variability could affect the reliability of CT scans to assess multiple screw types and sites. The purpose of this study was to assess the reliability of multi-observer analysis of CT scans for determining pedicle screw breach for various screw types and sites in patients with spinal deformity or degenerative pathologies.Entities:
Keywords: CT imaging; inter/intra observer reliability; pedicle screw breach
Year: 2014 PMID: 25694925 PMCID: PMC4325493 DOI: 10.14444/1011
Source DB: PubMed Journal: Int J Spine Surg ISSN: 2211-4599
Distribution of Screws.
| # of patients | # of screws | |
|---|---|---|
| Titanium | 11 | 93 |
| Stainless steel | 12 | 193 |
Figure 1Example demonstrating a less than 2 mm breach representative of best agreement.
Figure 2Example demonstrating a greater than 2 mm breach representative of worst agreement.
Reliability of CT Reading by Diagnosis.
| Diagnosis | # of patients | # of screws | Inter-observer ICC (UCL-LCL) | Intra-observer ICC (UCL-LCL) |
|---|---|---|---|---|
| Degenerative | 15 | 128 | 0.21 (0.44-0.05) | 0.26 (0.50-0.07) |
| Deformity | 8 | 134 | 0.38 (0.61-0.18) | 0.41 (0.63-0.21) |
ICC = Intraclass correlation coefficient; UCL = 95% upper confidence limit; LCL = 95% lower confidence limit. Only 262/286 screws were available for evaluating the effect of diagnosis on Inter- and Intrarater ICC.
Reliability of CT Reading: Titanium Versus Stainless Steel.
| Type of screw | # of patients | # of screws | Inter-observer ICC (UCL-LCL) | Intra-observer ICC (UCL-LCL) |
|---|---|---|---|---|
| Titanium | 11 | 93 | 0.306 (0.58-0.16) | 0.36 (0.58-0.16) |
| Stainless steel | 12 | 193 | 0.34 (0.58-0.14) | 0.40 (0.63-0.19) |
ICC = Intraclass correlation coefficient; UCL = 95% upper confidence limit; LCL = 95% lower confidence limit. All 286 screws were available for this comparison.
Effect of Age on Reliability of CT Read
| Age | # of patients | # of screws | Inter-observer ICC (UCL-LCL) | Intra-observer ICC (UCL-LCL) |
|---|---|---|---|---|
| <18 years | 12 | 156 | 0.24 (0.51-0.04) | 0.25 (0.51-0.39) |
| 18-60 years | 4 | 53 | 0.37 (0.58-0.17) | 0.61 (0.60-0.19) |
| >60 years | 7 | 52 | 0.16 (0.42-0.39) | 0.19 (0.47-0.45) |
ICC = Intraclass correlation coefficient; UCL = 95% upper confidence limit; LCL = 95% lower confidence limit; 261 of 286 screws were available for studying the effect of age on the inter- and intrarater ICC.