Accuracy of pedicular screw placement in vivo.

S D Gertzbein1, S E Robbins.   

Abstract

The accuracy of pedicular screw placement was assessed in 40 consecutive patients treated with the AO "Fixateur Interne." Postoperative CT scans were used to measure canal encroachment from the medial border of the pedicle, the angle of insertion and the point of entry. Eighty-one percent of the screws were placed within 2 mm of the medial border of the pedicle and 6% had 4-8 mm of canal encroachment with two patients developing minor neurological complications that spontaneously resolved. Four percent were inserted lateral to the pedicle. The parameters linked to satisfactory screw placement include entry point, angle of insertion and pedicular isthmus widths. Improvement in accuracy was noted in the latter 25% of screw insertions, reflecting the learning curve associated with this technique.

Entities:  

Mesh:

Year:  1990        PMID: 2326693     DOI: 10.1097/00007632-199001000-00004

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  245 in total

1.  Is intraoperative CT of posterior cervical spine instrumentation cost-effective and does it reduce complications?

Authors:  Andrew C Hecht; Steven M Koehler; Janelle C Laudone; Arthur Jenkins; Sheeraz Qureshi
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

2.  CT-Guided Transfacet Pedicle Screw Fixation in Facet Joint Syndrome: A Novel Approach.

Authors:  Luigi Manfré
Journal:  Interv Neuroradiol       Date:  2014-10-17       Impact factor: 1.610

3.  [Iso-C(3D0-assisted) navigated implantation of pedicle screws in thoracic lumbar vertebrae].

Authors:  K Wendl; J von Recum; A Wentzensen; P A Grützner
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

4.  Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine.

Authors:  Marcus Richter; Thomas Mattes; Balkan Cakir
Journal:  Eur Spine J       Date:  2003-11-22       Impact factor: 3.134

5.  [Intraoperative three-dimensional navigation for pedicle screw placement].

Authors:  P A Grützner; T Beutler; K Wendl; J von Recum; A Wentzensen; L-P Nolte
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

6.  [Accuracy of CT-based navitation of pedicle screws in the thoracic spine compared with conventional technique].

Authors:  K J Schnake; B König; U Berth; R J Schroeder; F Kandziora; U Stöckle; M Raschke; N P Haas
Journal:  Unfallchirurg       Date:  2004-02       Impact factor: 1.000

7.  A fluorolaser navigation system to guide linear surgical tool insertion.

Authors:  Jack T Liang; Takehito Doke; Shinya Onogi; Satoru Ohashi; Isao Ohnishi; Ichiro Sakuma; Yoshikazu Nakajima
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-05-25       Impact factor: 2.924

8.  A new 3-dimensional method for measuring precision in surgical navigation and methods to optimize navigation accuracy.

Authors:  Christopher J Kleck; Ian Cullilmore; Matthew LaFleur; Emily Lindley; Mark E Rentschler; Evalina L Burger; Christopher M J Cain; Vikas V Patel
Journal:  Eur Spine J       Date:  2015-09-22       Impact factor: 3.134

9.  Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study.

Authors:  Claudio Lamartina; Riccardo Cecchinato; Zsolt Fekete; Alberto Lipari; Meinrad Fiechter; P Berjano
Journal:  Eur Spine J       Date:  2015-10-23       Impact factor: 3.134

10.  Inserting pedicle screws in lumbar spondylolisthesis - The easy bone conserving way.

Authors:  Hitesh Lal; Lalit Kumar; Ramesh Kumar; Tankeshwar Boruah; Pankaj Kumar Jindal; Vinod Kumar Sabharwal
Journal:  J Clin Orthop Trauma       Date:  2017-03-06