Literature DB >> 18242939

Delayed presentation of aortic injury by pedicle screws: report of two cases and review of the literature.

Stavros K Kakkos1, Alexander D Shepard.   

Abstract

OBJECTIVES: Perforation of the aorta by pedicle screws is a rare but serious complication of spine fixation surgery. This article reviews the clinical presentation and management of this complication.
METHODS: Presented are two cases of thoracic aorta perforation by a pedicle screw and a review of the appropriate literature performed using a MEDLINE search.
RESULTS: Literature review identified eight additional patients. In most cases, aortic perforation was recognized and managed within 18 months of the spine surgery. Clinical presentation included acute bleeding, necessitating urgent exploration in two patients, and pseudoaneurysm formation in five cases, two of which were infected. Depending on the extent of aortic damage and the presence or absence of infection, management ranged from endovascular grafting, to screw burring with closure of the perforation site, to aortic reconstruction with a tube graft and complete orthopedic hardware removal. Outcome was favorable in all patients who were operated on.
CONCLUSIONS: The small number of reported cases indicates either the rarity of this complication or unawareness of its existence. The true incidence of this complication is probably under-reported. Orthopedic and vascular surgeons should be aware of this potentially fatal problem. Prevention remains the best treatment. Once encountered, a variety of techniques are available to manage this complication with reasonable outcome.

Entities:  

Mesh:

Year:  2008        PMID: 18242939     DOI: 10.1016/j.jvs.2007.11.005

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  22 in total

1.  Triggered electromyography for placement of thoracic pedicle screws: is it reliable?

Authors:  Amer F Samdani; Mark Tantorski; Patrick J Cahill; Ashish Ranade; Stephen Koch; David H Clements; Randal R Betz; Jahangir Asghar
Journal:  Eur Spine J       Date:  2010-12-18       Impact factor: 3.134

2.  Accuracy of free-hand placement of thoracic pedicle screws in adolescent idiopathic scoliosis: how much of a difference does surgeon experience make?

Authors:  Amer F Samdani; Ashish Ranade; Daniel M Sciubba; Patrick J Cahill; M Darryl Antonacci; David H Clements; Randal R Betz
Journal:  Eur Spine J       Date:  2009-10-29       Impact factor: 3.134

Review 3.  Aortic injury in spine surgery……What a spine surgeon needs to know.

Authors:  Safwan Alomari; Ryan Planchard; Sheng-Fu Larry Lo; Timothy Witham; Ali Bydon
Journal:  Neurosurg Rev       Date:  2021-04-14       Impact factor: 3.042

4.  The risks of aorta impingement from pedicle screw may increase due to aorta movement during posterior instrumentation in Lenke 5C curve: a computed tomography study.

Authors:  Ling Chen; Leilei Xu; Yong Qiu; Jun Qiao; Fei Wang; Zhen Liu; Benglong Shi; Bang-ping Qian; Zezhang Zhu
Journal:  Eur Spine J       Date:  2015-02-25       Impact factor: 3.134

5.  Accuracy of cannulated pedicle screw versus conventional pedicle screw for extra-pedicular screw placement in dysplastic pedicles without cancellous channel in adolescent idiopathic scoliosis: a computerized tomography (CT) analysis.

Authors:  Chee Kean Lee; Chris Yin Wei Chan; Siti Mariam Abd Gani; Mun Keong Kwan
Journal:  Eur Spine J       Date:  2017-08-17       Impact factor: 3.134

6.  [Prevention of aortic erosion by a bone cement skid : Thoracic endovascular aortic repair following kyphoplasty].

Authors:  M S Bischoff; K Meisenbacher; B Schmack; M Tanner; H Goldschmidt; C Kasperk; A Hyhlik-Dürr; D Böckler
Journal:  Orthopade       Date:  2016-11       Impact factor: 1.087

Review 7.  Improving safety in spinal deformity surgery: advances in navigation and neurologic monitoring.

Authors:  John M Flynn; Denis S Sakai
Journal:  Eur Spine J       Date:  2012-05-22       Impact factor: 3.134

8.  Patients with adolescent idiopathic scoliosis of Lenke type-1 curve exhibit specific pedicle width pattern.

Authors:  Kasim Abul-Kasim; Acke Ohlin
Journal:  Eur Spine J       Date:  2011-11-02       Impact factor: 3.134

9.  Delayed presentation of infected common iliac artery pseudoaneurysm caused by malpositioned pedicle screw after minimally invasive scoliosis surgery.

Authors:  Seung-Woo Suh; Gang-Un Kim; Hoon-Nyun Lee; Jae Hyuk Yang; Dong-Gune Chang
Journal:  Eur Spine J       Date:  2019-05-14       Impact factor: 3.134

10.  Delayed-iatrogenic injury of the thoracic aorta by an anterior spinal instrumentation.

Authors:  François Lavigne; E Mascard; C Laurian; J Dubousset; P Wicart
Journal:  Eur Spine J       Date:  2009-04-19       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.