Literature DB >> 12296683

Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement.

Ganesh Rao1, Darrel S Brodke, Matthew Rondina, Andrew T Dailey.   

Abstract

OBJECT: To validate computerized tomography (CT) scanning as a tool to assess the accuracy of thoracic pedicle screw placement, the authors compared its accuracy with that of direct visualization in instrumented cadaveric spine specimens.
METHODS: A grading scale was devised to score the placement of the pedicle screw. The grades ranged from 0 to 3 depending on the extent to which the pedicle had been violated. One hundred fifty-five pedicles were fitted with instrumentation in eight cadaveric spines. A single observer graded the appearance of the screw based on CT scans (3-mm axial sections with 1-mm overlap) and direct visualization of the specimen. The authors arrived at a Kappa value of 0.51, which suggested only moderate agreement between the two measurement techniques. Whereas CT had a positive predictive value of 95%, it had a negative predictive value of 62%.
CONCLUSIONS: The authors thus conclude that although CT scanning is the most valid tool to assess the accuracy of thoracic pedicle screw placement, it tends to overestimate the number of misplaced screws.

Mesh:

Year:  2002        PMID: 12296683     DOI: 10.3171/spi.2002.97.2.0223

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  24 in total

1.  Thoracic pedicle screw insertion in Asian cadaveric specimen: does radiological pedicle profile affect outcome?

Authors:  Chris Yin Wei Chan; Mun Keong Kwan; Lim Beng Saw
Journal:  Surg Radiol Anat       Date:  2010-09-17       Impact factor: 1.246

2.  A comparison of feasibility and safety of percutaneous fluoroscopic guided thoracic pedicle screws between Europeans and Asians: is there any difference?

Authors:  Mun Keong Kwan; Chee Kidd Chiu; Chris Yin Wei Chan; Reza Zamani; Nils Hansen-Algenstaedt
Journal:  Eur Spine J       Date:  2015-07-30       Impact factor: 3.134

3.  Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Michael Fox; Hudelmaier Martin; Rosmarie Forstner; Peter Augat; Rainer Penzkofer; Christian Pirich; H Kässmann; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

4.  Safety of thoracic pedicle screw application using the funnel technique in Asians: a cadaveric evaluation.

Authors:  Chris Yin Wei Chan; Mun Keong Kwan; Lim Beng Saw
Journal:  Eur Spine J       Date:  2009-09-11       Impact factor: 3.134

5.  A-Mode ultrasound guidance for pedicle screw advancement in ovine vertebral bodies.

Authors:  David T Raphael; Jin Ho Chang; Yao Ping Zhang; David Kudija; Thomas C Chen; K Kirk Shung
Journal:  Spine J       Date:  2010-03-27       Impact factor: 4.166

6.  Screw perforation rates in 359 consecutive patients receiving computer-guided pedicle screw insertion along the cervical to lumbar spine.

Authors:  Masashi Uehara; Jun Takahashi; Shota Ikegami; Shugo Kuraishi; Toshimasa Futatsugi; Hiroyuki Kato
Journal:  Eur Spine J       Date:  2016-11-02       Impact factor: 3.134

7.  Accuracy of a new intraoperative cone beam CT imaging technique (Artis zeego II) compared to postoperative CT scan for assessment of pedicle screws placement and breaches detection.

Authors:  Virginie Cordemans; Ludovic Kaminski; Xavier Banse; Bernard G Francq; Olivier Cartiaux
Journal:  Eur Spine J       Date:  2017-05-20       Impact factor: 3.134

8.  Accuracy of cannulated pedicle screw versus conventional pedicle screw for extra-pedicular screw placement in dysplastic pedicles without cancellous channel in adolescent idiopathic scoliosis: a computerized tomography (CT) analysis.

Authors:  Chee Kean Lee; Chris Yin Wei Chan; Siti Mariam Abd Gani; Mun Keong Kwan
Journal:  Eur Spine J       Date:  2017-08-17       Impact factor: 3.134

Review 9.  Esophageal perforation caused by a thoracic pedicle screw.

Authors:  Stanislas Marouby; Clément Jeandel; Djamel Louahem M'Sabah; Marion Delpont; Jérôme Cottalorda
Journal:  Eur Spine J       Date:  2018-05-03       Impact factor: 3.134

10.  Assessment of pelvic injuries treated with ilio-sacral screws: injury severity and accuracy of screw positioning.

Authors:  Miguel Pishnamaz; Thomas Dienstknecht; Barbara Hoppe; Christina Garving; Henning Lange; Frank Hildebrand; Philipp Kobbe; Hans-Christoph Pape
Journal:  Int Orthop       Date:  2015-08-11       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.