Literature DB >> 25689977

A 32-channel combined RF and B0 shim array for 3T brain imaging.

Jason P Stockmann1, Thomas Witzel1,2, Boris Keil1,2, Jonathan R Polimeni1,2, Azma Mareyam1, Cristen LaPierre1, Kawin Setsompop1,2, Lawrence L Wald1,2,3.   

Abstract

PURPOSE: We add user-controllable direct currents (DC) to the individual elements of a 32-channel radio-frequency (RF) receive array to provide B0 shimming ability while preserving the array's reception sensitivity and parallel imaging performance.
METHODS: Shim performance using constrained DC current (± 2.5A) is simulated for brain arrays ranging from 8 to 128 elements. A 32-channel 3-tesla brain array is realized using inductive chokes to bridge the tuning capacitors on each RF loop. The RF and B0 shimming performance is assessed in bench and imaging measurements.
RESULTS: The addition of DC currents to the 32-channel RF array is achieved with minimal disruption of the RF performance and/or negative side effects such as conductor heating or mechanical torques. The shimming results agree well with simulations and show performance superior to third-order spherical harmonic (SH) shimming. Imaging tests show the ability to reduce the standard frontal lobe susceptibility-induced fields and improve echo planar imaging geometric distortion. The simulation of 64- and 128-channel brain arrays suggest that even further shimming improvement is possible (equivalent to up to 6th-order SH shim coils).
CONCLUSION: Including user-controlled shim currents on the loops of a conventional highly parallel brain array coil is feasible with modest current levels and produces improved B0 shimming performance over standard second-order SH shimming.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  RF receive arrays; brain MRI; echo planar imaging; geometric distortion; multi-coil shimming

Mesh:

Year:  2015        PMID: 25689977      PMCID: PMC4771493          DOI: 10.1002/mrm.25587

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  Dynamic shim updating (DSU) for multislice signal acquisition.

Authors:  Robin A de Graaf; Peter B Brown; Scott McIntyre; Douglas L Rothman; Terence W Nixon
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Fast, automated, N-dimensional phase-unwrapping algorithm.

Authors:  Mark Jenkinson
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

4.  Regularized higher-order in vivo shimming.

Authors:  Dong-Hyun Kim; Elfar Adalsteinsson; Gary H Glover; Daniel M Spielman
Journal:  Magn Reson Med       Date:  2002-10       Impact factor: 4.668

5.  Image reconstruction in SNR units: a general method for SNR measurement.

Authors:  Peter Kellman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

Review 6.  Advances in functional and structural MR image analysis and implementation as FSL.

Authors:  Stephen M Smith; Mark Jenkinson; Mark W Woolrich; Christian F Beckmann; Timothy E J Behrens; Heidi Johansen-Berg; Peter R Bannister; Marilena De Luca; Ivana Drobnjak; David E Flitney; Rami K Niazy; James Saunders; John Vickers; Yongyue Zhang; Nicola De Stefano; J Michael Brady; Paul M Matthews
Journal:  Neuroimage       Date:  2004       Impact factor: 6.556

7.  Correction for geometric distortion in echo planar images from B0 field variations.

Authors:  P Jezzard; R S Balaban
Journal:  Magn Reson Med       Date:  1995-07       Impact factor: 4.668

8.  Dynamic shimming for multi-slice magnetic resonance imaging.

Authors:  G Morrell; D Spielman
Journal:  Magn Reson Med       Date:  1997-09       Impact factor: 4.668

9.  Selective saturation NMR imaging.

Authors:  B R Rosen; V J Wedeen; T J Brady
Journal:  J Comput Assist Tomogr       Date:  1984-10       Impact factor: 1.826

Review 10.  Fast robust automated brain extraction.

Authors:  Stephen M Smith
Journal:  Hum Brain Mapp       Date:  2002-11       Impact factor: 5.038

View more
  44 in total

1.  Modeling of active shimming of metallic needles for interventional MRI.

Authors:  Saikat Sengupta
Journal:  Magn Reson Med       Date:  2020-06-29       Impact factor: 4.668

2.  Integrated radio-frequency/wireless coil design for simultaneous MR image acquisition and wireless communication.

Authors:  Dean Darnell; Jonathan Cuthbertson; Fraser Robb; Allen W Song; Trong-Kha Truong
Journal:  Magn Reson Med       Date:  2018-09-14       Impact factor: 4.668

3.  High slew-rate head-only gradient for improving distortion in echo planar imaging: Preliminary experience.

Authors:  Ek T Tan; Seung-Kyun Lee; Paul T Weavers; Dominic Graziani; Joseph E Piel; Yunhong Shu; John Huston; Matt A Bernstein; Thomas K F Foo
Journal:  J Magn Reson Imaging       Date:  2016-02-26       Impact factor: 4.813

4.  Pushing the limits of ultra-high resolution human brain imaging with SMS-EPI demonstrated for columnar level fMRI.

Authors:  David A Feinberg; An T Vu; Alexander Beckett
Journal:  Neuroimage       Date:  2017-02-14       Impact factor: 6.556

5.  Adaptive integrated parallel reception, excitation, and shimming (iPRES-A) with microelectromechanical systems switches.

Authors:  Dean Darnell; Yixin Ma; Hongyuan Wang; Fraser Robb; Allen W Song; Trong-Kha Truong
Journal:  Magn Reson Med       Date:  2017-11-16       Impact factor: 4.668

Review 6.  Imaging at ultrahigh magnetic fields: History, challenges, and solutions.

Authors:  Kamil Uğurbil
Journal:  Neuroimage       Date:  2017-07-08       Impact factor: 6.556

7.  An orthogonal shim coil for 3T brain imaging.

Authors:  Jiazheng Zhou; Jason P Stockmann; Nicolas Arango; Thomas Witzel; Klaus Scheffler; Lawrence L Wald; Fa-Hsuan Lin
Journal:  Magn Reson Med       Date:  2019-10-21       Impact factor: 4.668

Review 8.  Magnetic Resonance Imaging technology-bridging the gap between noninvasive human imaging and optical microscopy.

Authors:  Jonathan R Polimeni; Lawrence L Wald
Journal:  Curr Opin Neurobiol       Date:  2018-05-11       Impact factor: 6.627

9.  High-fidelity, high-isotropic-resolution diffusion imaging through gSlider acquisition with B 1 + and T1 corrections and integrated ΔB0 /Rx shim array.

Authors:  Congyu Liao; Jason Stockmann; Qiyuan Tian; Berkin Bilgic; Nicolas S Arango; Mary Kate Manhard; Susie Y Huang; William A Grissom; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-08-01       Impact factor: 4.668

Review 10.  Toward 20 T magnetic resonance for human brain studies: opportunities for discovery and neuroscience rationale.

Authors:  Thomas F Budinger; Mark D Bird; Lucio Frydman; Joanna R Long; Thomas H Mareci; William D Rooney; Bruce Rosen; John F Schenck; Victor D Schepkin; A Dean Sherry; Daniel K Sodickson; Charles S Springer; Keith R Thulborn; Kamil Uğurbil; Lawrence L Wald
Journal:  MAGMA       Date:  2016-05-18       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.