Literature DB >> 9339449

Dynamic shimming for multi-slice magnetic resonance imaging.

G Morrell1, D Spielman.   

Abstract

Dynamic shimming has been implemented in three pulse sequences on a commercial GE Signa 1.5-T imaging system. Multi-slice field maps are acquired before the imaging sequence, and linear shim terms and center frequencies are calculated for each slice. During the imaging scan, the linear shim terms and center frequency are set before each pulse sequence repetition according to the current slice. Acquisition of multi-slice field maps and calculation of shim terms and center frequency for each slice are accomplished in a matter of seconds. Pulse sequences require only minimal modification to add dynamic shimming capability. Results are shown for a fat saturation spin-echo sequence, a single-shot echo-planar gradient-recalled echo sequence, and a spiral acquisition gradient-recalled echo sequence. In all cases, dynamic shimming with shim currents and center frequency optimized for each slice is shown to give better results than constant shim currents and a single center frequency optimized for the entire volume of interest.

Mesh:

Year:  1997        PMID: 9339449     DOI: 10.1002/mrm.1910380316

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  Degraded water suppression in small volume ¹H MRS due to localised shimming.

Authors:  Asa Carlsson; Maria Ljungberg; Göran Starck; Eva Forssell-Aronsson
Journal:  MAGMA       Date:  2011-01-06       Impact factor: 2.310

2.  Improved shim method based on the minimization of the maximum off-resonance frequency for balanced steady-state free precession (bSSFP).

Authors:  Jongho Lee; Michael Lustig; Dong-hyun Kim; John M Pauly
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

3.  On shimming approaches in 3T breast MRI.

Authors:  Ileana Hancu; Ambey Govenkar; Robert E Lenkinski; Seung-Kyun Lee
Journal:  Magn Reson Med       Date:  2012-05-03       Impact factor: 4.668

Review 4.  The future of acquisition speed, coverage, sensitivity, and resolution.

Authors:  Lawrence L Wald
Journal:  Neuroimage       Date:  2012-03-06       Impact factor: 6.556

5.  Stages: sub-Fourier dynamic shim updating using nonlinear magnetic field phase preparation.

Authors:  Walter Rt Witschey; Sebastian Littin; Chris A Cocosco; Daniel Gallichan; Gerrit Schultz; Hans Weber; Anna Welz; Jürgen Hennig; Maxim Zaitsev
Journal:  Magn Reson Med       Date:  2013-02-25       Impact factor: 4.668

6.  High slew-rate head-only gradient for improving distortion in echo planar imaging: Preliminary experience.

Authors:  Ek T Tan; Seung-Kyun Lee; Paul T Weavers; Dominic Graziani; Joseph E Piel; Yunhong Shu; John Huston; Matt A Bernstein; Thomas K F Foo
Journal:  J Magn Reson Imaging       Date:  2016-02-26       Impact factor: 4.813

7.  Multicoil shimming of the mouse brain.

Authors:  Christoph Juchem; Peter B Brown; Terence W Nixon; Scott McIntyre; Douglas L Rothman; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2011-03-25       Impact factor: 4.668

8.  Whole-brain three-dimensional T2-weighted BOLD functional magnetic resonance imaging at 7 Tesla.

Authors:  Jun Hua; Qin Qin; Peter C M van Zijl; James J Pekar; Craig K Jones
Journal:  Magn Reson Med       Date:  2013-12-12       Impact factor: 4.668

9.  A 32-channel combined RF and B0 shim array for 3T brain imaging.

Authors:  Jason P Stockmann; Thomas Witzel; Boris Keil; Jonathan R Polimeni; Azma Mareyam; Cristen LaPierre; Kawin Setsompop; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2015-02-17       Impact factor: 4.668

10.  Fat suppression for 1H MRSI at 7T using spectrally selective adiabatic inversion recovery.

Authors:  Priti Balchandani; Daniel Spielman
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.