Integrated radio-frequency/wireless coil design for simultaneous MR image acquisition and wireless communication.

Dean Darnell1, Jonathan Cuthbertson1,2, Fraser Robb3, Allen W Song1,2, Trong-Kha Truong1,2.   

Abstract

PURPOSE: An innovative radio-frequency (RF) coil design that allows RF currents both at the Larmor frequency and in a wireless communication band to flow on the same coil is proposed to enable simultaneous MRI signal reception and wireless data transfer, thereby minimizing the number of wired connections in the scanner without requiring any modifications or additional hardware within the scanner bore.
METHODS: As a first application, the proposed integrated RF/wireless coil design was further combined with an integrated RF/shim coil design to perform not only MR image acquisition and wireless data transfer, but also localized B0 shimming with a single coil. Proof-of-concept phantom experiments were conducted with such a coil to demonstrate its ability to simultaneously perform these three functions, while maintaining the RF performance, wireless data integrity, and B0 shimming performance.
RESULTS: Performing wirelessly controlled shimming of localized B0 inhomogeneities with the coil substantially reduced the B0 root-mean-square error (>70%) and geometric distortions in echo-planar images without degrading the image quality, signal-to-noise ratio (<1.7%), or wireless data throughput (maximum variance = 0.04 Mbps) of the coil.
CONCLUSIONS: The RF/wireless coil design can provide a solution for wireless data transfer that can be easily integrated into existing MRI scanners for a variety of applications.
© 2018 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  B0 shimming; RF coil; WiFi; Wireless; iPRES

Mesh:

Year:  2018        PMID: 30277273      PMCID: PMC6347493          DOI: 10.1002/mrm.27513

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking system.

Authors:  M Zaitsev; C Dold; G Sakas; J Hennig; O Speck
Journal:  Neuroimage       Date:  2006-04-05       Impact factor: 6.556

Review 2.  Prospective motion correction in brain imaging: a review.

Authors:  Julian Maclaren; Michael Herbst; Oliver Speck; Maxim Zaitsev
Journal:  Magn Reson Med       Date:  2012-05-08       Impact factor: 4.668

3.  Spatiotemporal magnetic field monitoring for MR.

Authors:  Christoph Barmet; Nicola De Zanche; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2008-07       Impact factor: 4.668

4.  Inductively coupled wireless RF coil arrays.

Authors:  S B Bulumulla; E Fiveland; K J Park; T K Foo; C J Hardy
Journal:  Magn Reson Imaging       Date:  2014-12-16       Impact factor: 2.546

5.  A Millimeter-Wave Digital Link for Wireless MRI.

Authors:  Kamal Aggarwal; Kiran R Joshi; Yashar Rajavi; Mazhareddin Taghivand; John M Pauly; Ada S Y Poon; Greig Scott
Journal:  IEEE Trans Med Imaging       Date:  2016-10-27       Impact factor: 10.048

6.  Integrated parallel reception, excitation, and shimming (iPRES).

Authors:  Hui Han; Allen W Song; Trong-Kha Truong
Journal:  Magn Reson Med       Date:  2013-04-29       Impact factor: 4.668

7.  Integrated RF/shim coil array for parallel reception and localized B0 shimming in the human brain.

Authors:  Trong-Kha Truong; Dean Darnell; Allen W Song
Journal:  Neuroimage       Date:  2014-09-28       Impact factor: 6.556

8.  Dynamic multi-coil shimming of the human brain at 7 T.

Authors:  Christoph Juchem; Terence W Nixon; Scott McIntyre; Vincent O Boer; Douglas L Rothman; Robin A de Graaf
Journal:  J Magn Reson       Date:  2011-07-23       Impact factor: 2.229

9.  Integrated parallel reception, excitation, and shimming (iPRES) with multiple shim loops per radio-frequency coil element for improved B0 shimming.

Authors:  Dean Darnell; Trong-Kha Truong; Allen W Song
Journal:  Magn Reson Med       Date:  2016-05-13       Impact factor: 4.668

Review 10.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

View more
  2 in total

1.  Wireless Reconfigurable RF Detector Array for Focal and Multiregional Signal Enhancement.

Authors:  Wei Qian; Xin Yu; Chunqi Qian
Journal:  IEEE Access       Date:  2020-07-24       Impact factor: 3.367

2.  Wireless Powered Encoding and Broadcasting of Frequency Modulated Detection Signals.

Authors:  Wei Qian; Xin Yu; Chunqi Qian
Journal:  IEEE Access       Date:  2020-11-04       Impact factor: 3.367