Literature DB >> 12594742

Dynamic shim updating (DSU) for multislice signal acquisition.

Robin A de Graaf1, Peter B Brown, Scott McIntyre, Douglas L Rothman, Terence W Nixon.   

Abstract

Dynamic shim updating (DSU) is a technique for achieving optimal magnetic field homogeneity over extended volumes by dynamically updating an optimal shim setting for each individual slice in a multislice acquisition protocol. Here the practical implementation of DSU using all first- and second-order shims is described. In particular, the hardware modifications and software requirements are demonstrated. Furthermore, the temporal effects of dynamically switching shim currents are investigated and a Z(2)-to-Z(0) compensation unit is described and implemented to counteract the temporal Z(0) variations following a change in the Z(2) shim current. The optimal shim settings for all slices are determined with a quantitative and user-independent, multislice phase-mapping sequence. The performance of DSU is evaluated from multislice phase maps and spectroscopic images acquired on rat brain in vivo. DSU improved the magnetic field homogeneity over all spatial slices, with a more pronounced effect on the slices positioned away from the magnet isocenter, thereby making the magnetic field homogeneity highly uniform over an extended volume. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 12594742     DOI: 10.1002/mrm.10404

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  Automatic high-order shimming using parallel columns mapping (PACMAP).

Authors:  Yan Zhang; Shizhe Li; Jun Shen
Journal:  Magn Reson Med       Date:  2009-10       Impact factor: 4.668

Review 2.  The future of acquisition speed, coverage, sensitivity, and resolution.

Authors:  Lawrence L Wald
Journal:  Neuroimage       Date:  2012-03-06       Impact factor: 6.556

3.  Stages: sub-Fourier dynamic shim updating using nonlinear magnetic field phase preparation.

Authors:  Walter Rt Witschey; Sebastian Littin; Chris A Cocosco; Daniel Gallichan; Gerrit Schultz; Hans Weber; Anna Welz; Jürgen Hennig; Maxim Zaitsev
Journal:  Magn Reson Med       Date:  2013-02-25       Impact factor: 4.668

4.  Multicoil shimming of the mouse brain.

Authors:  Christoph Juchem; Peter B Brown; Terence W Nixon; Scott McIntyre; Douglas L Rothman; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2011-03-25       Impact factor: 4.668

5.  A 32-channel combined RF and B0 shim array for 3T brain imaging.

Authors:  Jason P Stockmann; Thomas Witzel; Boris Keil; Jonathan R Polimeni; Azma Mareyam; Cristen LaPierre; Kawin Setsompop; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2015-02-17       Impact factor: 4.668

6.  Localization errors in MR spectroscopic imaging due to the drift of the main magnetic field and their correction.

Authors:  Assaf Tal; Oded Gonen
Journal:  Magn Reson Med       Date:  2012-11-19       Impact factor: 4.668

7.  Integrated parallel reception, excitation, and shimming (iPRES).

Authors:  Hui Han; Allen W Song; Trong-Kha Truong
Journal:  Magn Reson Med       Date:  2013-04-29       Impact factor: 4.668

8.  Dynamic multi-coil shimming of the human brain at 7 T.

Authors:  Christoph Juchem; Terence W Nixon; Scott McIntyre; Vincent O Boer; Douglas L Rothman; Robin A de Graaf
Journal:  J Magn Reson       Date:  2011-07-23       Impact factor: 2.229

9.  Dynamic Shimming of the Human Brain at 7 Tesla.

Authors:  Christoph Juchem; Terence W Nixon; Piotr Diduch; Douglas L Rothman; Piotr Starewicz; Robin A de Graaf
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2010-07-06       Impact factor: 1.176

10.  Improved shimming for fMRI specifically optimizing the local BOLD sensitivity.

Authors:  Evelyne Balteau; Chloe Hutton; Nikolaus Weiskopf
Journal:  Neuroimage       Date:  2009-08-12       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.