Literature DB >> 25654397

Comparison of cranial facet joint violation rate between percutaneous and open pedicle screw placement: a systematic review and meta-analysis.

Liang Wang1, Yipeng Wang, Bin Yu, Zhengyao Li, Ye Li.   

Abstract

Percutaneous and open pedicle screw placements have been widely used in lumbar fusion surgery. However, there are conflicting reports of cranial facet joint violation rate for the 2 techniques. To better determine the rate of cranial facet joint violation, a systematic review and meta-analysis was performed in the present study. We searched the established electronic literature databases including MEDLINE, EMBASE, World of Science, and the Cochrane Central Register of Controlled Trials databases for trials involving the 2 pedicle screw placement techniques. Odds ratio (OR) and 95% confidence interval (CI) were calculated. Four comparative trials with a cumulative sample size of 881 patients and 1755 cranial pedicle screws were identified and analyzed. The results showed that cranial facet joint violation rate was 18.18% (154/847) in percutaneous group and 18.72% (170/908) in open group. The pooled data revealed that there was no significant difference in the violation rate (OR 0.75, 95% CI 0.24-2.30, P = 0.62). In addition, there was also no significant difference for the rate of severe violation between the 2 techniques (OR 1.20, 95% CI 0.55-2.62, P = 0.64, random effect model). Based on the current data, the meta-analysis shows that similar cranial facet joint violation rate occurs during the percutaneous and open pedicle screw placement techniques. In addition, taking the limitations of this study into consideration, it was still not appropriate to draw such a strong conclusion. More well-designed prospective randomized controlled trials are needed to assess violation rate for the 2 techniques in the future.

Entities:  

Mesh:

Year:  2015        PMID: 25654397      PMCID: PMC4602715          DOI: 10.1097/MD.0000000000000504

Source DB:  PubMed          Journal:  Medicine (Baltimore)        ISSN: 0025-7974            Impact factor:   1.889


INTRODUCTION

Since first introduced by Boucher,[1] the pedicle screw system has been widely used in the instrumentation of the lumbar spine.[2,3] The open pedicle screw (OPS) insertion has proved to be a safe and standard means for lumbar fusion surgery. With the emergence of minimally invasive techniques, the use of percutaneous pedicle screws has become increasingly popular.[4-6] Compared with the conventional open technique, the percutaneous pedicle screw placement could avoid extensive detachment of muscle, leading to reduced blood loss, less postoperative pain, faster recovery, and rehabilitation.[7,8] Cranial facet joint violation of lumbar surgery has been an underappreciated consequence of pedicle screw placement. Injury to the cranial facet joint has been regarded as a cause of adjacent segment degeneration.[9,10] Violation of facet joint could cause postoperative pain due to the impingement and instability. A better understanding of cranial facet joint violation could elucidate the prevalence of junction syndrome and facet joint arthropathy following the lumbar fusion surgery. Previous studies reported that the rates of cranial facet joint violation ranged from 7% to 58% with percutaneous pedicle screw placement technique[11-13] and from 15% to 100% using open technique.[14-16] However, it is still not clear whether percutaneous technique is accompanied with higher cranial facet joint violation rate in lumbar surgery. Thus, we compared the rate of facet joint violation for the 2 techniques in this review and meta-analysis.

MATERIALS AND METHODS

The reporting of the present review adhered to the preferred reporting items for systematic reviews and meta-analyses statements.[17] Ethical approval was not necessary for this meta-analysis as the results for publication only involved identified pooled data from individual studies that have received ethics approval.

Literature Search

A literature research was identified by searching MEDLINE, EMBASE, World of Science, and the Cochrane Central Register of Controlled Trials databases. Retrieval time was from the time when databases were built through June 2014. The key words and text words used in the search included percutaneous, open, pedicle screw, minimally invasive, cranial facet joint, superior facet joint, facet joint violation, and facet impingement. To identify other relevant studies, we manually scanned reference lists from identified trials and reviewed articles. Two investigators independently reviewed all subjects, abstracts, and full texts of articles that were potentially eligible based on abstract review. The eligible trials were then selected according to the study eligibility criteria.

Study Eligibility Criteria

We systematically reviewed published studies according to the following criteria: original clinical comparative studies, the studies compared the rate of cranial facet joint violation between percutaneous and OPS placement techniques in lumbar surgery, the studies reported the detailed amount of cases suffering from the cranial facet violation, and computed tomography (CT) was used to assess facet joint violation. All selected studies were independently reviewed by 2 investigators for inclusion into the final analysis. Any inconsistencies were resolved through discussion until a consensus was reached.

Data Extraction

Data were extracted by 2 independent reviewers. The outcome of interest was rate of cranial facet joint violation for 2 different pedicle screw insertion techniques. The following data were also extracted: year of publication, study type, number of patients, and patient characteristics. Any disagreement between the reviewers was resolved by discussion.

Assessment of Methodological Quality

The Newcastle–Ottawa Quality Assessment Scale was used to assess nonrandomized observational studies.[18,19] This scoring system evaluated studies on the basis of the selection of patients in the case and control groups, the comparability of the 2 groups, and the outcomes of the single studies. On the basis of these criteria, studies are scored between 0 and 9 stars. Six stars or greater was considered to be sufficiently high quality.[20]

Statistical Analysis

The rate of cranial facet joint violation, as the dichotomous data, was analyzed using odds ratio (OR) measure and 95% confidence interval (CI). Moreover, heterogeneity across trials were evaluated with I2 statistic, and was defined if I2 was >50%. If heterogeneity existed, a random-effect model was used to assess the overall estimate. Otherwise, a fixed-effect model was chosen. All tests were 2-tailed and P < 0.05 was considered significantly different. Then, the meta-analyses were performed on the extracted data with the Review Manager (Version 5.1. Copenhagen: The Nordic Cochrane Centre, Cochrane Collaboration, 2011).

RESULTS

Selected Studies and Characteristics

The details of literature search and selection are displayed in Figure 1. After detailed evaluation, 4 independent retrospective trials[21-24] with a cumulative sample size of 881 patients and 1755 cranial pedicle screws were included in the overall meta-analysis. For the quality assessment of the 4 studies, the Newcastle–Ottawa Quality Assessment Scale grades were 6 to 8 stars, which were regarded as high quality of the studies. The detailed characteristics of these studies are shown in Table 1.
FIGURE 1

Flow chart of eligibility selection.

TABLE 1

Characteristics of Included Studies

Flow chart of eligibility selection. Characteristics of Included Studies

Meta-Analysis Results

All the 4 articles[21-24] presented the number of pedicle screw suffering from facet joint violation. There are 847 pedicle screws in percutaneous insertion group and 908 in open technique group. The rate of cranial facet joint violation was 18.18% (154/847) in percutaneous group and 18.72% (170/908) in open group. The pooled data revealed that there was no significant difference in the complication rate (OR 0.75, 95% CI 0.24–2.30, P = 0.62, random effect model) with the heterogeneity of I2 = 89%, P < 0.01 (Figure 2).
FIGURE 2

Forest plot: OR in cranial facet joint violation rate and 95% CI for percutaneous versus OPS placement. No significant difference was found for the violation rate between the 2 methods. “Favors OPS” means the violation rate is lower in OPS fixation group. “Favors PPS” means the violation rate is lower in PPS fixation group. CI = confidence interval, OPS = open pedicle screw, OR = odds ratio, PPS = percutaneous pedicle screw.

Forest plot: OR in cranial facet joint violation rate and 95% CI for percutaneous versus OPS placement. No significant difference was found for the violation rate between the 2 methods. “Favors OPS” means the violation rate is lower in OPS fixation group. “Favors PPS” means the violation rate is lower in PPS fixation group. CI = confidence interval, OPS = open pedicle screw, OR = odds ratio, PPS = percutaneous pedicle screw. Because of the obvious heterogeneity among the 4 trials, the sensitivity analysis was added. Statistical heterogeneity is reduced if the trial by Yson et al[22] is removed. The pedicle screws were inserted using intraoperative Three-Dimentional (3-D) CT computer navigation in the study by Yson et al[22] comparing with fluoroscopic guidance in other 3 studies. Removal of this trial reduced the heterogeneity and still results in no significant difference for facet joint violation rate between the 2 techniques (Figure 3).
FIGURE 3

Forest plot: OR in cranial facet joint violation rate and 95% CI for percutaneous versus OPS placement in sensitivity analysis. No significant difference was found for the violation rate between the 2 methods. “Favors OPS” means the violation rate is lower in OPS fixation group. “Favors PPS” means the violation rate is lower in PPS fixation group. CI = confidence interval, OPS = open pedicle screw, OR = odds ratio, PPS = percutaneous pedicle screw.

Forest plot: OR in cranial facet joint violation rate and 95% CI for percutaneous versus OPS placement in sensitivity analysis. No significant difference was found for the violation rate between the 2 methods. “Favors OPS” means the violation rate is lower in OPS fixation group. “Favors PPS” means the violation rate is lower in PPS fixation group. CI = confidence interval, OPS = open pedicle screw, OR = odds ratio, PPS = percutaneous pedicle screw. Among the 4 trials, 2[21,22] presented different grading criteria to evaluate the degree of facet joint violation. All the 4 trials adopted the CT scans to analyze the violations. Because the severe facet joint violation may cause severe adverse effects after surgery, we made additional analysis of severe degree of facet joint violation. In this study, the severe violation was defined as intra-articular facet joint violation, which refers to the screw crossing or traveling within the articular surface of the facet. Yson et al[22] reported 0 pedicle screw with severe violation in percutaneous group and 10 in open group. Babu et al[21] reported 41 in percutaneous group and 23 in open group. The cases included in another 2 study[21,22] are intra-articular only. The pooled data indicated that the rate of severe violation was 7.91% (67/847) in percutaneous group and 5.73% (52/908) in open group. However, there was no significant difference between the 2 techniques (OR 1.20, 95% CI 0.55–2.62, P = 0.64, random effect model) (Figure 4).
FIGURE 4

Forest plot: OR in severe violation rate and 95% CI for percutaneous versus OPS placement. No significant difference was found for the violation rate between the 2 methods. “Favors OPS” means the violation rate is lower in OPS fixation group. “Favors PPS” means the violation rate is lower in PPS fixation group. CI = confidence interval, OPS = open pedicle screw, OR = odds ratio, PPS = percutaneous pedicle screw.

Forest plot: OR in severe violation rate and 95% CI for percutaneous versus OPS placement. No significant difference was found for the violation rate between the 2 methods. “Favors OPS” means the violation rate is lower in OPS fixation group. “Favors PPS” means the violation rate is lower in PPS fixation group. CI = confidence interval, OPS = open pedicle screw, OR = odds ratio, PPS = percutaneous pedicle screw.

DISCUSSION

Facet joint violation during pedicle screw placement has long been a concern, which is regarded as a risk factor for adjacent segment degeneration following the lumbar fusion. Percutaneous pedicle screw placement may accompany more frequent cranial facet joint violations because of the potential limitation of screw entry site selection. There are conflicting data for the facet joint violation related to both percutaneous and OPS insertion. To our knowledge, this study is the first quantitative comparative meta-analysis comparing the rate of cranial facet violation in percutaneous and OPS placement in lumbar surgery. Four comparative trials in the literatures were included in our systematic review. In order to assess the facet joint violation rate in 2 different pedicle screw insertion techniques, we extracted relative data as much as possible and pooled the outcome whenever possible. The reported facet violation rates caused by pedicle screw insertion have been highly variable in the literatures with either percutaneous or open techniques. Yson et al[22] reviewed the literatures and concluded that the weighted mean rated was 27% for percutaneous technique and 23% for open group. Knox et al[11] reviewed the postoperative CT scans of 61 patients who underwent minimally invasive transforaminal lumbar interbody fusion and found that the cranial facet joint violation was 6.6% (8/122). Park et al[13] and Patel et al[12] reported that the rates of the cranial facet joint violation were 31.5% (58/184) and 58% (28/48), respectively, by percutaneously placed pedicle screws in lumbar spine surgery. As for the open insertion technique, different violation rates were reported. Shah et al[14] reported that the facet joint violation occurred in 20% of the screws in OPS insertion. Moshirfar et al[15] retrospectively reviewed 204 patients with OPS insertion and revealed that the facet violation rate was 15%. Chen et al[16] revealed a 100% incidence of facet violation using the Roy–Camille method whereas 36% with the Weinstein method. In the present study, we pooled the data from 4 comparative trials consisting of 881 patients and 1755 cranial pedicle screws. The meta-analysis indicated that although the rate of cranial facet joint violation in open technique group is higher than percutaneous group (18.72% vs 18.18%), there is no significant statistical difference. Because of high heterogeneity among the 4 studies, a sensitivity analysis was performed by removing a study, which did not affect the pooled results. Among the facet joint violations, severe violation refers to the screw's travels within the facet joint articular surface, which damages the facet complex. It could lead to the severe adverse effect of biomechanical forces and accelerate adjacent segment disease. So, additional analysis of severe violation was also performed. The analysis indicated that although the rate of severe violation was higher in percutaneous techniques than open group (7.91% vs 5.73%), there was no significant statistical difference. In a biomechanical cadaveric study, Cardoso et al[25] reported that the range of motion in supra-adjacent segment increased after bilateral facet breach. In a finite element analysis, Kim et al[26] showed that facet joint violation model caused by pedicle screws yield great increases in facet contact force and intradiscal pressure. These biomechanical analyses showed that facet joint violation might be a significant risk factor for the development of adjacent segment degeneration after spinal fusion with pedicle screw fixation. The violation rates for different lumbar level were also analyzed in some studies. In the research by Park et al,[13] the facet joint violation related to percutaneous pedicle screw placement occurred approximately 3.3 times more frequently at L5-S1 level than at the other-level fusions. Moshirfar et al[15] found that 48% of the cranial facet joint violation occurred at the level of L5 during the OPS fixation. Yson et al[22] revealed that there is a trend of an increasing likelihood of facet joint violation form L1 to L5. This may be due to the facet orientation and presence of iliac crests at the more caudal levels of lumbar spine. The facet joint rotates progressively into a more coronal orientation from L1 to L5.[27] These anatomical characteristics interrupt the selection of ideal entry point and sufficient insertion trajectory of pedicle screws for both percutaneous and open techniques. There are several literatures referring the risk factors for facet joint violation. Both the studies by Babu et al[21] and Lau et al[23] reminded that obesity is an independent risk factor for increased facet joint violation. For obese patients, it is often difficult to obtain the correct entry point and trajectory for pedicle screw insertion. In addition, Babu et al[21] also indicated that age <65 and depth of the spine were identified as independent risk factors for severe facet violation. The study by Shah et al[14] showed that the incidence of the cranial facet joint violation was independent of the side, sex, diagnosis, level of screw insertion, and whether it was a primary or revision case. Some limitations exist in this meta-analysis. First, 1 prominent drawback is that only 4 retrospective comparative studies were included in this meta-analysis. The results of pooled analysis might therefore be accompanied by bias. Second, the included studies had obvious heterogeneity, which lowered the quality of evidence for the outcome. Further studies on facet joint violation related to pedicle screw placement are needed in order to better understand and reduce the adjacent segment disease after lumbar fusion.

CONCLUSIONS

In conclusion, our meta-analysis indicates that percutaneous and OPS placements accompany similar cranial facet joint violation rates. In addition, taking the limitations in this study into consideration, it is still not appropriate to make a strong conclusion related to the 2 techniques. More well-designed prospective randomized controlled trials are needed to assess the violation rate for the 2 techniques in the future.
  26 in total

1.  Off-pump myocardial revascularization is associated with less incidence of stroke in elderly patients.

Authors:  Thanos Athanasiou; Sharif Al-Ruzzeh; Pankaj Kumar; Mary-Clare Crossman; Mohamed Amrani; John R Pepper; Rex Del Stanbridge; Roberto Casula; Brian Glenville
Journal:  Ann Thorac Surg       Date:  2004-02       Impact factor: 4.330

2.  Radiologic evaluation of adjacent superior segment facet joint violation following transpedicular instrumentation of the lumbar spine.

Authors:  Rajesh R Shah; Saeed Mohammed; Asif Saifuddin; Benjamin A Taylor
Journal:  Spine (Phila Pa 1976)       Date:  2003-02-01       Impact factor: 3.468

3.  A method of spinal fusion.

Authors:  H H BOUCHER
Journal:  J Bone Joint Surg Br       Date:  1959-05

Review 4.  Adjacent segment disease after lumbar or lumbosacral fusion: review of the literature.

Authors:  Paul Park; Hugh J Garton; Vishal C Gala; Julian T Hoff; John E McGillicuddy
Journal:  Spine (Phila Pa 1976)       Date:  2004-09-01       Impact factor: 3.468

5.  The orientation of laminae and facet joints in the lower lumbar spine.

Authors:  J P Van Schaik; H Verbiest; F D Van Schaik
Journal:  Spine (Phila Pa 1976)       Date:  1985 Jan-Feb       Impact factor: 3.468

Review 6.  Comprehensive literature review. Pedicle screw fixation devices.

Authors:  M A Yahiro
Journal:  Spine (Phila Pa 1976)       Date:  1994-10-15       Impact factor: 3.468

7.  Depression and risk for Alzheimer disease: systematic review, meta-analysis, and metaregression analysis.

Authors:  Raymond L Ownby; Elizabeth Crocco; Amarilis Acevedo; Vineeth John; David Loewenstein
Journal:  Arch Gen Psychiatry       Date:  2006-05

8.  Percutaneous pedicle screw fixation of the lumbar spine: preliminary clinical results.

Authors:  Kevin T Foley; Sanjay K Gupta
Journal:  J Neurosurg       Date:  2002-07       Impact factor: 5.115

9.  Superior articulating facet violation: percutaneous versus open techniques.

Authors:  Sean M Jones-Quaidoo; Mladen Djurasovic; R Kirk Owens; Leah Y Carreon
Journal:  J Neurosurg Spine       Date:  2013-04-19

10.  Postfusion instability at the adjacent segments after rigid pedicle screw fixation for degenerative lumbar spinal disorders.

Authors:  Y Aota; K Kumano; S Hirabayashi
Journal:  J Spinal Disord       Date:  1995-12
View more
  6 in total

1.  Percutaneous pedicle screw placements: accuracy and rates of cranial facet joint violation using conventional fluoroscopy compared with intraoperative three-dimensional computed tomography computer navigation.

Authors:  Tetsuro Ohba; Shigeto Ebata; Koji Fujita; Hironao Sato; Hirotaka Haro
Journal:  Eur Spine J       Date:  2016-03-08       Impact factor: 3.134

2.  Robotic-Navigated Percutaneous Pedicle Screw Placement Has Less Facet Joint Violation Than Fluoroscopy-Guided Percutaneous Screws.

Authors:  Gennadiy A Katsevman; Raven D Spencer; Scott D Daffner; Sanjay Bhatia; Robert A Marsh; John C France; Shari Cui; Patricia Dekeseredy; Cara L Sedney
Journal:  World Neurosurg       Date:  2021-05-04       Impact factor: 2.210

3.  Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12): A 2-dimensional multiplanar reconstruction study using computed tomography.

Authors:  Jun Xuan; Jian Chen; Hui He; Hai-Ming Jin; Di Zhang; Yao-Sen Wu; Nai-Feng Tian; Xiang-Yang Wang
Journal:  Medicine (Baltimore)       Date:  2017-02       Impact factor: 1.889

4.  Multivariate analysis of pedicle screw invasion of the proximal facet joint after lumbar surgery.

Authors:  Peng Tao Wang; Jia Nan Zhang; Tuan Jiang Liu; Jun Song Yang; Ding Jun Hao
Journal:  BMC Musculoskelet Disord       Date:  2022-01-06       Impact factor: 2.362

5.  Comparison of degenerative lumbar spondylolisthesis and isthmic lumbar spondylolisthesis: effect of pedicle screw placement on proximal facet invasion in surgical treatment.

Authors:  Peng Tao Wang; Jia Nan Zhang; Tuan Jiang Liu; Jun Song Yang; Ding Jun Hao
Journal:  BMC Musculoskelet Disord       Date:  2022-01-03       Impact factor: 2.362

6.  Rate and Risk Factors of Superior Facet Joint Violation during Cortical Bone Trajectory Screw Placement: A Comparison of Robot-Assisted Approach with a Conventional Technique.

Authors:  Xiao-Feng Le; Zhan Shi; Qi-Long Wang; Yun-Feng Xu; Jing-Wei Zhao; Wei Tian
Journal:  Orthop Surg       Date:  2019-12-20       Impact factor: 2.071

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.