Literature DB >> 21474080

Cranial facet joint violations by percutaneously placed pedicle screws adjacent to a minimally invasive lumbar spinal fusion.

Yung Park1, Joong Won Ha, Yun Tae Lee, Na Young Sung.   

Abstract

BACKGROUND CONTEXT: Protecting cranial facet joint is a modifiable risk factor that may decrease the incidence of adjacent segment disease after lumbar spinal fusion. Percutaneously instrumented screws may more frequently violate cranial facet joints because of the potential limitation of screw entry site selection. To our knowledge, however, there is no study that has evaluated the cranial facet joint violations adjacent to minimally invasive lumbar fusion related to percutaneously placed pedicle screws.
PURPOSE: We investigated the incidence and relating factors of cranial facet joint violations by percutaneous pedicle screws. STUDY DESIGN/
SETTING: A retrospective study of prospectively collecting data. PATIENT SAMPLE: The sample comprises 184 pedicle screws percutaneously placed at the cranial fusion segments in 92 patients who underwent minimally invasive lumbar spinal fusion. OUTCOME MEASURES: The facet joint violations adjacent to a cranial fusion segment were examined on the postoperative computed tomography (CT) scans.
METHODS: Two independent observers retrospectively examined all the postoperative CT images. A facet joint was considered violated if any of the following situations were encountered: pedicle screw clearly within the facet joint; pedicle screw head clearly within the facet joint; and pedicle screw and/or screw head within 1 mm from or abutting the facet joint, without clear joint involvement.
RESULTS: The incidence of the violations was 50% (46/92) of all patients and 31.5% (58/184) of all screws, which were significantly higher than the previously reported rates with the traditional open procedure (50% vs. 23.5% of all patients, p<.001; 31.5% vs. 15.2% of all screws, p<.001). The violations occurred approximately 3.3 times more frequently at the most cranial pedicle screws of L5 pedicle than at the other pedicles (70.8% vs. 42.6%, odds ratio [OR]=3.3, p=.021). Logistic regression analysis revealed a significant trend toward reducing the incidence of the violations as increasing the year of surgery (OR=0.7, p=.008). The incidence showed no significant relationships with patients' age, gender, body mass index, preoperative diagnosis, the number of fused segments, or the side of screw placement.
CONCLUSIONS: Our data raise a concern about the higher incidence of cranial facet joint violations by percutaneously placed pedicle screws than that previously reported rates by traditionally instrumented screws. Furthermore, more care should be taken to avoid cranial facet joint violations when the surgeon is a novice to percutaneous pedicle screw placement and/or minimally invasive fusion surgery is considered at the L5-S1 segment. Crown
Copyright © 2011. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21474080     DOI: 10.1016/j.spinee.2011.02.007

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  22 in total

1.  Changes in the adjacent segment 10 years after anterior lumbar interbody fusion for low-grade isthmic spondylolisthesis.

Authors:  Kyung-Chul Choi; Jin-Sung Kim; Hyeong-Ki Shim; Yong Ahn; Sang-Ho Lee
Journal:  Clin Orthop Relat Res       Date:  2014-06       Impact factor: 4.176

2.  Percutaneous pedicle screw placements: accuracy and rates of cranial facet joint violation using conventional fluoroscopy compared with intraoperative three-dimensional computed tomography computer navigation.

Authors:  Tetsuro Ohba; Shigeto Ebata; Koji Fujita; Hironao Sato; Hirotaka Haro
Journal:  Eur Spine J       Date:  2016-03-08       Impact factor: 3.134

Review 3.  Minimally invasive transforaminal lumbar interbody fusion (MI-TLIF): A review of indications, technique, results and complications.

Authors:  Bhavuk Garg; Nishank Mehta
Journal:  J Clin Orthop Trauma       Date:  2019-01-14

4.  Anterior stand-alone fusion revisited: a prospective clinical, X-ray and CT investigation.

Authors:  Christoph J Siepe; Katrin Stosch-Wiechert; Franziska Heider; Phat Amnajtrakul; Alexander Krenauer; Wolfgang Hitzl; Ulrike Szeimies; Axel Stäbler; H Michael Mayer
Journal:  Eur Spine J       Date:  2014-12-05       Impact factor: 3.134

5.  Comparison of robot-assisted versus fluoroscopy-assisted minimally invasive transforaminal lumbar interbody fusion for degenerative lumbar spinal diseases: 2-year follow-up.

Authors:  Lianlei Wang; Chao Li; Zheng Wang; Donglai Li; Yonghao Tian; Suomao Yuan; Xinyu Liu
Journal:  J Robot Surg       Date:  2022-07-05

6.  Multimodal Applications of 3D-Navigation in Single-Level Minimally Invasive Transforaminal Lumbar Interbody Fusion: Impacts on Precision, Accuracy, Complications, and Radiation Exposure.

Authors:  Arvind G Kulkarni; Pritem A Rajamani; Sandeep Tapashetti; Tushar Sathish Kunder
Journal:  Int J Spine Surg       Date:  2022-07-14

7.  Comparison of superior-level facet joint violations during open and percutaneous pedicle screw placement.

Authors:  Ranjith Babu; Jong G Park; Ankit I Mehta; Tony Shan; Peter M Grossi; Christopher R Brown; William J Richardson; Robert E Isaacs; Carlos A Bagley; Maragatha Kuchibhatla; Oren N Gottfried
Journal:  Neurosurgery       Date:  2012-11       Impact factor: 4.654

8.  Minimally invasive reduction and percutaneous posterior fixation of one-level traumatic thoraco-lumbar and lumbar spine fractures.

Authors:  Marco Tinelli; Friederike Töpfer; Michael Kreinest; Stefan Matschke; Paul A Grützner; Arnold J Suda
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-05-16

9.  Analysis of risk factors for adjacent superior vertebral pedicle-induced facet joint violation during the minimally invasive surgery transforaminal lumbar interbody fusion: a retrospective study.

Authors:  Zhi-Li Zeng; Long Jia; Wei Xu; Yan Yu; Xiao Hu; Yong-Wei Jia; Jian-Jie Wang; Li-Ming Cheng
Journal:  Eur J Med Res       Date:  2015-09-24       Impact factor: 2.175

Review 10.  Open Versus Minimally Invasive Fixation Techniques for Thoracolumbar Trauma: A Meta-Analysis.

Authors:  Steven J McAnany; Samuel C Overley; Jun S Kim; Evan O Baird; Sheeraz A Qureshi; Paul A Anderson
Journal:  Global Spine J       Date:  2015-06-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.