Christopher K Macgowan1, Sarah Joy Stoops2, Yu-Qing Zhou3, Lindsay S Cahill3, John G Sled4. 1. 1] Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada [2] Division of Physiology and Experimental Medicine, Hospital for Sick Children, Peter Gilgan Centre for Research and Learning, Toronto, Ontario, Canada. 2. Division of Physiology and Experimental Medicine, Hospital for Sick Children, Peter Gilgan Centre for Research and Learning, Toronto, Ontario, Canada. 3. Mouse Imaging Centre, The Hospital for Sick Children, Peter Gilgan Centre for Research and Learning, Toronto, Ontario, Canada. 4. 1] Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada [2] Mouse Imaging Centre, The Hospital for Sick Children, Peter Gilgan Centre for Research and Learning, Toronto, Ontario, Canada.
Abstract
Genetic and surgical mouse models are commonly used to study cerebrovascular disease, but their size makes invasive hemodynamic testing technically challenging. The purpose of this study was to demonstrate a noninvasive measurement of cerebrovascular impedance and wave reflection in mice using high-frequency ultrasound in the left common carotid artery (LCCA), and to examine whether microvascular changes associated with hypercapnia could be detected with such an approach. Ten mice (C57BL/6J) were studied using a high-frequency ultrasound system (40 MHz). Lumen area and blood flow waveforms were obtained from the LCCA and used to calculate pulse-wave velocity, input impedance, and reflection amplitude and transit time under both normocapnic and hypercapnic (5% CO2) ventilation. With hypercapnia, vascular resistance was observed to decrease by 87%±12%. Although the modulus of input impedance was unchanged with hypercapnia, a phase decrease indicative of increased total arterial compliance was observed at low harmonics together with an increased reflection coefficient in both the time (0.57±0.08 versus 0.68±0.08, P=0.04) and frequency domains (0.62±0.08 versus 0.73±0.06, P=0.02). Interestingly, the majority of LCCA blood flow was found to pass into the internal carotid artery (range=76% to 90%, N=3), suggesting that hemodynamic measurements in this vessel are a good metric for intracerebral reactivity in mouse.
Genetic and surgical mouse models are commonly used to study cerebrovascular disease, but their size makes invasive hemodynamic testing technically challenging. The purpose of this study was to demonstrate a noninvasive measurement of cerebrovascular impedance and wave reflection in mice using high-frequency ultrasound in the left common carotid artery (LCCA), and to examine whether microvascular changes associated with hypercapnia could be detected with such an approach. Ten mice (C57BL/6J) were studied using a high-frequency ultrasound system (40 MHz). Lumen area and blood flow waveforms were obtained from the LCCA and used to calculate pulse-wave velocity, input impedance, and reflection amplitude and transit time under both normocapnic and hypercapnic (5% CO2) ventilation. With hypercapnia, vascular resistance was observed to decrease by 87%±12%. Although the modulus of input impedance was unchanged with hypercapnia, a phase decrease indicative of increased total arterial compliance was observed at low harmonics together with an increased reflection coefficient in both the time (0.57±0.08 versus 0.68±0.08, P=0.04) and frequency domains (0.62±0.08 versus 0.73±0.06, P=0.02). Interestingly, the majority of LCCA blood flow was found to pass into the internal carotid artery (range=76% to 90%, N=3), suggesting that hemodynamic measurements in this vessel are a good metric for intracerebral reactivity in mouse.
Under normal physiological conditions, the cerebral microvasculature has a large capacity to dilate or constrict in response to changing metabolic demand and changes in cardiac output. However, cerebral blood flow autoregulation can be impaired by a wide variety of pathological conditions including atherosclerosis, stroke, sickle cell anemia, syncope, traumatic brain injury, and Alzheimer's disease.[1, 2, 3, 4, 5, 6] Impaired autoregulation is assessed clinically by measurement of cerebrovascular resistance or impedance, normally derived from direct catheter measurements of pressure and flow in a major artery.[7, 8, 9, 10] Early work using catheter measurements suggested that increased reflections could be a biomarker of microcirculatory abnormalities; however, the invasiveness of catheterization has limited the broad application of this approach. Transcranial ultrasound provides a noninvasive alternative for studying cerebrovascular reactivity, based on changes in the Doppler waveform of central cerebral blood vessels such as the middle cerebral artery. This idea that blood flow pulsatility provides an indirect measure of microvascular impedance is well accepted, for instance in the context of transcranial ultrasound assessment of late-gestation at-risk fetuses.[11] Unfortunately, such an approach requires an acoustic window to the target vessel, and failure rates of 25% have been reported in adults, where the mature skull is a barrier to access.[12] There is potential, however, to infer the characteristics of the cerebral microcirculation based on the pulsation characteristics of the common carotid artery (CCA). Methods to do so generally rely on measurement of blood flow using Doppler ultrasound and estimates of blood pressure based on either surface measurements of arterial pulsation (tonometry) or imaging measurements of lumen area pulsation.[4, 13, 14, 15]In the present work, high-frequency ultrasound is used to study vascular impedance and wave reflection in mice noninvasively. Mice offer an advantage for such research in that genetically identical individuals may be raised and manipulated under controlled conditions, as done here. Furthermore, the growing list of genetically and experimentally induced mouse models of cerebrovascular disorders provides immediate applications for this technology in basic research studies.[16, 17, 18] Previous work by others in this area has described pressure wave propagation velocity (pulse-wave velocity (PWV)) and wave reflection by ultrasound in the carotid arteries of experimental mice,[19, 20] but has not specifically examined whether microvascular changes can be detected with this approach. Here we present a method for assessing input impedance and wave reflection in the mouse CCA, and evaluate whether these measurements were sensitive to changes in cerebral microvascular tone induced by hypercapnia.
Materials and Methods
Animals
Ten male C57BL/6J mice from the Jackson Laboratory (Bar Harbor, ME, USA) were studied at 12 weeks of age (mean±s.d. body weight of 26.5±1.9 g). All animal experiments were approved by the Animal Care Committee at the Toronto Centre for Phenogenomics, following the Canadian Council on Animal Care guidelines and the Animal Research: Reporting of In Vivo Experiments (ARRIVE) guidelines.
Animal Preparation
Mice were anesthetized with isoflurane (4% for induction; 1% for maintenance) and then endotracheally intubated (22 gauge catheter), placed supine on a temperature-regulated platform and mechanically ventilated using a pressure-controlled ventilator (TOPO Small Animal Ventilator, Kent Scientific, Torrington, CT, USA). The same ventilation parameters were used for all of the mice in the study (135 cycles per minute). In addition, 0.2 mg/kg pancuronium bromide (Sigma-Aldrich, St Louis, MO, USA) was injected intraperitoneally for muscle relaxation, ensuring optimal breathing control throughout the experiment. Hair from the throat and chest was removed using Nair (Church & Dwight Co., Inc., Ewing, NJ, USA) to improve contact with the ultrasound transducer. During ultrasound imaging, the body temperature was maintained at 36 to 37°C and the heart rate and respiration rate were continuously monitored.
Ultrasound Imaging
A high-frequency ultrasound imaging system (Vevo 2100, VisualSonics, Toronto, ON, Canada) with a 40 MHz linear array transducer was used (wavelength ~35 μm).[21] The M-mode trace and pulsed Doppler velocity spectrum were recorded from the left CCA, ~3 mm proximal to its bifurcation. M-mode recordings (pulse repetition rate=1 kHz) were made with the ultrasound beam perpendicular to the left CCA, and pulsed Doppler velocity (pulse repetition rate=15 to 25 kHz) was measured with the sample volume adjusted to cover the entire vascular lumen and the smallest intercept angle possible (<60°) between the flow direction and the ultrasound beam. Diameter and flow velocity measurements were recorded while the mice inhaled a gas mixture of 30% O2/70% N2 (normocapnia) and were repeated after the gas mixture was changed to 5% CO2, 30% O2, balance N2 (hypercapnia), a paradigm based on human studies of cerebrovascular reserve[22] (30% O2 was necessary to prevent spontaneous gasping in mice during hypercapnia). The mice were exposed to the hypercapnic gas mixture for 5 minutes before the diameter and flow velocity measurements were acquired. This protocol was validated in a separate series of mice (N=22) while monitoring pCO2 levels transcutaneously (TCM4, Radiometer Canada, London, ON, Canada) and produced pCO2 values (mean±s.e.) in the two gas conditions of 35.5±2.3 mm Hg and 53.5±3.5 mm Hg, respectively.
Image Processing
M-mode and Doppler data were analyzed offline using automated routines developed in commercial software (Matlab—Mathworks, Natick, MA, USA). Vessel diameter was extracted from the M-mode data by automatically tracing the near and far wall positions, based on peak wall intensity. To avoid assumptions about the velocity profile, the spatial mean velocity (angle corrected) was quantified as the instantaneous centroid of the Doppler velocity spectrum, calculated using values between a manually specified lower bound and the maximum velocity envelope. Each waveform was then divided into cardiac cycles based on the recorded electrocardiogram. These area or velocity waveforms for individual cardiac cycles were truncated to have uniform length and averaged together. This produced consistent diameter and velocity waveforms, and provided an estimate of area and flow uncertainty. From the average waveforms, lumen area and flow volume versus time were calculated and used for subsequent impedance and reflection analysis.
Impedance and Reflection Analysis
Impedance and reflection estimates were obtained by passing the lumen area and flow waveforms through the following analysis pipeline.First, the average area and flow waveforms were temporally aligned based on the timing of their initial upstroke (foot). The timing of the upstroke was established from the intersection of linear fits to the diastolic baseline and systolic rise of each waveform.[23] Next, the PWV was calculated based on the relative change in flow with respect to area during systole, a period assumed to be free of reflection.[24, 25] Plotting flow versus area, a line was fit to the systolic portion using total least squares regression to account for uncertainty in both the area and flow estimates.[26] Through this process, linearity between area and flow during the systolic period was evaluated and used to refine the temporal alignment between the flow and area waveforms, on average by 0.5±0.6 milliseconds. The flow waveforms were then decomposed into their forward and reflected components according to the following equations:[27, 28, 29]where q+ and q− are the calculated forward and reflected flow waveforms, respectively, and qm and am are the measured flow and area waveforms, respectively. Forward and reflected area waveforms were similarly calculated.Wave transit time was defined as the delay between the onsets of q+ and q−. Transit time was then used in conjunction with PWV to estimate the distance to the nearest reflection site.Reflection coefficients were calculated in both the time domain and frequency domain. The time domain reflection coefficient Γ was defined as the ratio of the peak-to-peak amplitudes of q− and q+. The frequency-domain definition of reflection was the conventional complex-valued parameter, Γ(ω), equal to the ratio of the frequency spectra of q− and q+. Here ω is in units of harmonics of the fundamental frequency. Frequency domain reflection was summarized as the magnitude of the reflection coefficient at the fundamental frequency, |Γ(ω=1)|.[8]The input impedance, Zin(ω), was calculated at nonzero frequencies using the following expression:where ρ is the density of blood (1.06 g/mL), ā is the average vessel area over the cardiac cycle, and Am(ω) and Qm(ω) are the frequency spectra of the measured area and flow waveforms, respectively.Finally, the ratio of the systolic accelerations (i.e., upstroke slope) of q+ and q−, normalized by their peak-to-peak amplitudes, was used to quantify smoothing of the reflected wave relative to the forward wave.
Statistical Analysis
Statistical analysis was performed using R 3.0.2 (http://www.r-project.org/). Results were summarized as mean±s.d. unless noted otherwise. Unmasked testing for population differences between the control and hypercapnia groups was performed using a paired t-test (two tailed). Statistical significance was defined as P≤0.05. Table data is reported as mean±s.d. Figure error bars show s.e.
Results
Representative ultrasound data from the left CCA of one mouse are presented in Figure 1, demonstrating the extraction of velocity and diameter waveforms with high precision and reproducibility from the source images. Although ultrasound image quality was good in all mice, 2 of the 10 mice had poorly defined ECG traces, which led to artifactually high variance in the flow and area waveforms between consecutive cardiac cycles. These two mice were thus excluded from subsequent analysis.
Figure 1
Measurement of blood velocity and lumen diameter in the left common carotid artery of mouse. (A) B-mode image used to prescribe the Doppler sample volume and corresponding spectral Doppler waveform. (B) B-mode image used to prescribe the M-mode scan, and the corresponding M-mode waveform. Superimposed on the Doppler spectra and the M-mode data are the mean velocity and wall position traces, respectively (white lines). Electrocardiography (red lines) and respiratory waveforms (yellow lines) are also shown, the former used to segment individual cardiac cycles. (C and D) Segmented diameter and velocity waveforms, respectively. Gray lines represent data from consecutive cardiac cycles and the black line represents their average.
A summary of the hemodynamic variables measured under each gas condition is presented in Table 1. Relative to control conditions, heart rate was elevated during hypercapnia. Similarly, mean velocity and mean flow both increased with hypercapnia, whereas mean vessel area, a metric for mean pressure, showed a nonsignificant trend for higher values. Based on the flow and area changes, vascular resistance decreased with hypercapnia to 87%±12% of its baseline value.
Table 1
Heart rate, lumen area, blood velocity, and blood flow under nomocapnia and hypercapnia
Control (mean±s.d.)
Hypercapnia (mean±s.d.)
P
Absolute change (mean±s.d.)
% change (mean)
Heart rate (b.p.m)
508±37
548±28
0.05
39±46
8%
Area (mm2)
0.14±0.05
0.18±0.01
0.09
0.04±0.05
35%
Mean velocity (cm/s)
8.8±2.1
10.2±2.3
0.03
1.5±1.5
18%
Mean flow (cm3/min)
0.8±0.3
1.1±0.3
0.01
0.3±0.3
59%
Figure 2 demonstrates decomposition of a flow waveform into its forward and reflected components using the experimental flow and area data from Figure 1. Pulse-wave velocity is estimated first, based on the change in flow versus area (Figure 2A). The waveforms were then scaled, their baselines subtracted (Figure 2B), and the forward and reflected waveforms were calculated using equation (1). The resulting forward and reflected waveforms for these representative data are presented in Figure 2C. Quantitative results from this analysis, applied to the eight mice, are presented in Table 2 and described below.
Figure 2
Decomposition of a flow waveform into its forward and reflected components. (A) Calculation of pulse-wave velocity (PWV) based on the change in flow versus area. (B) Scaled area (am) and flow (qm) waveforms, after baseline subtraction. (C) Calculation of the forward (q+) and reflected (q) waveforms using equation (1).
Table 2
Calculated hemodynamic parameters
Control (mean±s.d.)
Hypercapnia (mean±s.d.)
P
Absolute change (mean±s.d.)
% change (mean)
PWV (m/s)
1.3±0.3
1.5±0.4
0.15
0.2±0.3
15%
Transit time (ms)
8.0±1.2
7.1±0.6
0.09
0.8±1.2
9%
Reflection site (mm)
5.2±1.3
5.2±1.2
0.9
0.1±1.6
5%
Γt
0.57±0.08
0.68±0.08
0.04
0.10±0.12
20%
|Γ(ω=1)|
0.62±0.08
0.73±0.06
0.02
0.10±0.09
18%
PWV, pulse-wave velocity; Γ, time-domain reflection coefficient; |Γ(ω=1)|, frequency-domain reflection coefficient at first harmonic (fundamental frequency).
Pulse-wave velocity and reflection transit time were not statistically different between control and hypercapnic conditions. In both states, the calculated mean distance to the sites of reflection was ~5.2 mm, a position beyond the carotid bifurcation near the carotid canal at the base of the skull, and in proximity of small side branches of both the internal and external carotids.[30]The modulus and phase of Zin(ω), averaged across all mice, is plotted in Figure 3. Under both gas conditions, |Zin| decreased quickly over the first four harmonics. At higher harmonics, |Zin| changes were more gradual and a weak minimum was observed at the seventh harmonic. No significant difference in |Zin| between the two gas states was detected. The phase of Zin was similar under each gas state, but a more negative phase was detected at the fundamental frequency with hypercapnia.
Figure 3
Input impedance measured in the left common carotid artery of mouse. Lines represent mean values obtained from eight mice under normocapnic (dark line) and hypercapnic (gray line) ventilation. For clarity, s.e. in the mouse are plotted one sided. Significant differences between normocapnic and hypercapnic values are marked by an asterisk.
Reflection values calculated in the time domain, Γ, and frequency domain, |Γ(ω=1)|, were strongly correlated (R2=0.82, mean difference±s.d.=0.04±0.03), consistent with previous studies of human systemic reflection.[8] The frequency-domain reflection coefficient, averaged across all mice, is shown in Figure 4. Values decreased to a minimum at the fifth to sixth harmonic before rising again at higher frequencies. Interestingly, increased reflection was observed with hypercapnia, based on both definitions of reflection (Table 2).
Figure 4
Modulus of the reflection coefficient measured in the left common carotid artery of mouse. Lines represent mean values obtained from eight mice under normocapnic (dark line) and hypercapnic (gray line) ventilation. For clarity, s.e. in the mean are plotted one sided. Significant differences between normocapnic and hypercapnic values are marked by an asterisk.
Under both gas conditions, the onset slope of the reflected wave was significantly less than that of the forward wave. Under control conditions, the normalized slopes for the reflected and forward waves were 97±22 per second versus 54±23 per second (P=0.003), respectively. These normalized values were not significantly different under hypercapnia. Potential sources of reduced acceleration of the reflected wave include having a distribution of distances to downstream reflection sites, a reduced reflection of high-frequency components, and a frequency-dependent PWV (wave dispersion).
Discussion
Vascular impedance and wave reflection in the mouse CCA were studied using noninvasive ultrasound under normocapnic and hypercapnic conditions. Compared with work using intraluminal catheters, the use of ultrasound offers significant advantages including a more natural physiological state, unencumbered by intravascular devices, and reduced morbidity associated with intervention to facilitate longitudinal assessment. Magnetic resonance imaging provides similar capabilities, enabling measurement of blood flow in large vessels[31] and also tissue perfusion.[32] Moreover, combined with hypercapnia challenges, magnetic resonance imaging techniques such as blood oxygen level-dependent imaging and arterial spin labeling can be used to assess microvascular reactivity.[22, 33] However, application of magnetic resonance imaging to small animals is challenging because acquisition times are relatively long compared with the timescale of physiological changes, and achieving adequate spatial and temporal resolutions is difficult. In this regard, high-frequency ultrasound is a convenient tool that provides both anatomical and physiological data at high spatial and temporal resolutions for studies of cerebrovascular reactivity in mice.Here, we review the findings of the present study in the context of previous work. With hypercapnia, CCA flow was found to increase by 59% over control conditions. This is comparable to previous human studies reporting an internal carotid artery (ICA) flow increase of ~50% with 5% CO2.[34] The increase in flow observed in our study can be partially attributed to a rise in heart rate (~8%); however, the balance of the increase indicates a preferential dilation of the cerebral vasculature relative to the systemic circulation. Previous studies have directly visualized cerebral vasodilation in mouse, using high energy x-ray angiography.[35] These studies varied arterial CO2 between hypocapnic and hypercapnic conditions and observed a 25% dilation of the central cerebral vessels.The PWV values observed in the present study (1.3±0.3 m/s) were generally lower than the 3 m/s reported in a previous study of 5- to 6-month-old CD-1mice.[36] Differences in age, anesthetic and mouse strain may explain these differences. In addition, there are differences in methodology between the two studies. Specifically, the present study used M-mode rather than color Doppler to assess cross-sectional area with greater precision. We also used total least square regression when estimating PWV to avoid bias associated with uncertainty in both the flow and area estimates. Finally, PWV is also prone to underestimation when the systolic rise of the flow and area traces is not completely free of reflected waves.[37]Although the goal of the present study was not to measure PWV per se, misestimation of this parameter had the potential to bias our estimate of reflection. We evaluated this bias by extending the analytic framework of Segers et al,[37] and simulated the effect of PWV error on the calculated reflection magnitude. For typical values of downstream reflection (e.g., |Γ(ω)|≥0.2), a 50% error in PWV resulted in just a 5% error in reflection. Intuitively, reflection estimates are less biased than PWV because of cancellation of errors in the calculated forward and backward waves, such that their ratio in the frequency domain (i.e., the reflection coefficient) is relatively preserved. It is important to note that calculations of the input impedance (Zin(ω)) do not assume a reflection-free period and are independent of the PWV calculation, so are not affected by PWV bias. Based on these observations, the reflection coefficient and input impedance appear to be robust parameters for the evaluation of downstream microvascular tone, even in the presence of more proximal reflections that may bias the calculation of PWV obtained using the flow-area method.Pulse-wave velocity and transit time were not significantly affected by hypercapnia, consistent with the expectation that the biomechanics of the conduit arteries and the distance to the site of reflection would not be affected by hypercapnia-induced changes in vessel tone. The estimated position of the nearest reflection site, 5.2±1.3 mm distal to the measurement site, is interesting as it places the first reflector beyond the carotid bifurcation. Moreover, because most of the mouse CCA blood flow passes through the ICA to the brain (range=76% to 90%, N=3), we speculate that the initial reflection arises from bifurcations within the ICA circulation at the level of the circle of Willis.Impedance and reflection values for the CCA vary between species, depending on factors such as the relative tissue volumes supplied by the ICA and external carotid artery (ECA), and collateralization between the two networks.[38] This is important because the resistance per unit volume of the ECA circulation is higher than that of the intracerebral circulation, and the vasculature supplied by the ECA is less reactive to hypercapnia.[34, 38] As a result, differences in flow distribution between the ECA and ICA, and the relative volumes of tissue perfused by each, will affect CCA impedance measurements. In the present study, flow through the ICA was several fold greater than that through the ECA, indicating that CCA impedance measurements should closely parallel those of the ICA in mice. Indeed, the mouse CCA impedance (Figure 3) resembled that measured in canine studies after ECA occlusion.[38] This observation that mouse CCA flow is primarily intracerebral supports the use of mouse models to study intracerebral physiology based on hemodynamic measurements from the larger and more accessible CCA.The CCA impedance observed in this study was similar to that predicted by a three-element Windkessel model.[27] Using this model, the hypercapnic decrease in the phase of Zin at low harmonics may be interpreted as an increase in total arterial compliance.[8] This subtle change, consistent with relaxed cerebrovascular tone under hypercapnia, produced a small but statistically significant increase in the reflection coefficient at the fundamental frequency. Because neither |Zin| nor PWV (i.e., characteristic impedance) was significantly affected by hypercapnia, this reflection change may be attributed to the change in compliance alone, demonstrating the ability of this approach to interrogate specific aspects of the mouse cerebrovasculature.A limitation of this study was the need to combine M-mode and Doppler data acquired with the transducer in different orientations. Dual-transducer systems exist to overcome this limitation but were not available for this study.[20] However, heart rates were stable within each gas state (coefficient of variation <1%), and the measured diameter and velocity waveforms were highly reproducibility between beats (Figure 1), supporting the use of data acquired at different times.A second limitation of this noninvasive study was the inability to calculate vascular resistance, Zin(0). Linearity between vessel cross-sectional area and arterial pressure has previously been demonstrated in the human carotid artery.[15] While this permitted calculation of relative changes in arterial pressure, absolute pressure remained unknown and, as a result, vascular resistance could not be calculated from the acquired ultrasound data. However, the relative vascular resistance of hypercapnia versus control conditions could be calculated (87±12%), based on the relatives changes in flow and area. Furthermore, the noninvasive nature of this approach enables study of impedance in vasculature too small to instrument without affecting the physiology of interest.A third limitation in this study was the assumption of constant PWV between the sites of measurement and reflection, used for calculation of the distance to the site of reflection. Vascular compliance depends on factors such as the ratio of elastin to collagen, the degree of muscularization, and the ratio of wall thickness to lumen diameter, which may vary along the length of a vessel.In conclusion, we have demonstrated the use of high-frequency ultrasound for the study of cerebrovascular impedance and reflection in a cohort of mice under hypercapnia and control conditions. This approach may be applied to genetic and experimental mouse models of human pathology to improve our understanding of disrupted cerebrovascular reactivity and its response to therapy.
Authors: Anilkumar K Reddy; George E Taffet; Sridhar Madala; Lloyd H Michael; Mark L Entman; Craig J Hartley Journal: Ultrasound Med Biol Date: 2003-03 Impact factor: 2.998
Authors: M L Forbes; K S Hendrich; P M Kochanek; D S Williams; J K Schiding; S R Wisniewski; S F Kelsey; S T DeKosky; S H Graham; D W Marion; C Ho Journal: J Cereb Blood Flow Metab Date: 1997-08 Impact factor: 6.200
Authors: Anum Rahman; Yu-Qing Zhou; Yohan Yee; Jun Dazai; Lindsay S Cahill; John Kingdom; Christopher K Macgowan; John G Sled Journal: Am J Physiol Heart Circ Physiol Date: 2017-03-31 Impact factor: 4.733
Authors: Henning U Voss; Jonathan P Dyke; Karsten Tabelow; Nicholas D Schiff; Douglas J Ballon Journal: J Cereb Blood Flow Metab Date: 2016-01-01 Impact factor: 6.200
Authors: Nikhil Mistry; C David Mazer; John G Sled; Alan H Lazarus; Lindsay S Cahill; Max Solish; Yu-Qing Zhou; Nadya Romanova; Alexander G M Hare; Allan Doctor; Joseph A Fisher; Keith R Brunt; Jeremy A Simpson; Gregory M T Hare Journal: Am J Physiol Regul Integr Comp Physiol Date: 2018-01-10 Impact factor: 3.619
Authors: Lindsay S Cahill; Clare L Whitehead; Sebastian R Hobson; Greg Stortz; John C Kingdom; Ahmet Baschat; Kellie E Murphy; Lena Serghides; Christopher K Macgowan; John G Sled Journal: Biol Reprod Date: 2019-10-25 Impact factor: 4.285
Authors: Rojan Saghian; Lindsay Cahill; Anum Rahman; Joseph Steinman; Greg Stortz; John Kingdom; Christopher Macgowan; John Sled Journal: IEEE Trans Biomed Eng Date: 2021-11-23 Impact factor: 4.538
Authors: Lindsay S Cahill; Shiri Shinar; Clare L Whitehead; Sebastian R Hobson; Greg Stortz; Viji Ayyathurai; Anjana Ravi Chandran; Anum Rahman; John C Kingdom; Ahmet Baschat; Kellie E Murphy; Lena Serghides; Christopher K Macgowan; John G Sled Journal: Am J Obstet Gynecol MFM Date: 2020-10-06