Literature DB >> 3744394

Time domain resolution of forward and reflected waves in the aorta.

J K Li.   

Abstract

Mesh:

Year:  1986        PMID: 3744394     DOI: 10.1109/TBME.1986.325903

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


× No keyword cloud information.
  10 in total

1.  Non-linear separation of pressure, velocity and wave intensity into forward and backward components.

Authors:  Jonathan P Mynard; Malcolm R Davidson; Daniel J Penny; Joseph J Smolich
Journal:  Med Biol Eng Comput       Date:  2012-03-25       Impact factor: 2.602

2.  Intra-aortic balloon pumping reduces the increased arterial load caused by acute cardiac depression, modifying central and peripheral load determinants in a time- and flow-related way.

Authors:  Daniel Bia; Edmundo I Cabrera-Fischer; Yanina Zócalo; Ricardo L Armentano
Journal:  Heart Vessels       Date:  2011-11-09       Impact factor: 2.037

3.  Ultrasound detection of altered placental vascular morphology based on hemodynamic pulse wave reflection.

Authors:  Anum Rahman; Yu-Qing Zhou; Yohan Yee; Jun Dazai; Lindsay S Cahill; John Kingdom; Christopher K Macgowan; John G Sled
Journal:  Am J Physiol Heart Circ Physiol       Date:  2017-03-31       Impact factor: 4.733

4.  Effect of compliance on a time-domain estimate of the characteristic impedance of the pulmonary artery during acute pulmonary hypertension.

Authors:  P R Fourie; A R Coetzee
Journal:  Med Biol Eng Comput       Date:  1993-09       Impact factor: 2.602

5.  Arterial windkessel parameter estimation: a new time-domain method.

Authors:  Y Shim; A Pasipoularides; C A Straley; T G Hampton; P F Soto; C H Owen; J W Davis; D D Glower
Journal:  Ann Biomed Eng       Date:  1994 Jan-Feb       Impact factor: 3.934

6.  Determination of Aortic Characteristic Impedance and Total Arterial Compliance From Regional Pulse Wave Velocities Using Machine Learning: An in-silico Study.

Authors:  Vasiliki Bikia; Georgios Rovas; Stamatia Pagoulatou; Nikolaos Stergiopulos
Journal:  Front Bioeng Biotechnol       Date:  2021-05-13

7.  Evaluation of cerebrovascular impedance and wave reflection in mouse by ultrasound.

Authors:  Christopher K Macgowan; Sarah Joy Stoops; Yu-Qing Zhou; Lindsay S Cahill; John G Sled
Journal:  J Cereb Blood Flow Metab       Date:  2014-12-17       Impact factor: 6.200

8.  Misinterpretation of the Determinants of Elevated Forward Wave Amplitude Inflates the Role of the Proximal Aorta.

Authors:  Timothy S Phan; John K-J Li; Patrick Segers; Julio A Chirinos
Journal:  J Am Heart Assoc       Date:  2016-02-19       Impact factor: 5.501

9.  Measurement of Pulmonary Artery Wave Reflection Before and After Mitral Valvuloplasty in Canine Patients With Pulmonary Hypertension Caused by Myxomatous Mitral Valve Disease.

Authors:  Tomohiko Yoshida; Kazumi Shimada; Lina Hamabe; Tsuyoshi Uchide; Ryou Tanaka; Katsuhiro Matsuura
Journal:  Front Vet Sci       Date:  2021-12-02

10.  Estimation of Pulmonary Arterial Wave Reflection by Echo-Doppler: A Preliminary Study in Dogs With Experimentally-Induced Acute Pulmonary Embolism.

Authors:  Tomohiko Yoshida; Tokuhisa Uejima; Syunta Komeda; Katsuhiro Matsuura; Akiko Uemura; Hiromasa Hayama; Takeshi Yamashita; Zeki Yilmaz; Ryou Tanaka
Journal:  Front Physiol       Date:  2021-12-08       Impact factor: 4.566

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.