Literature DB >> 19647922

A new 15-50 MHz array-based micro-ultrasound scanner for preclinical imaging.

F Stuart Foster1, James Mehi, Marc Lukacs, Desmond Hirson, Chris White, Chris Chaggares, Andrew Needles.   

Abstract

Most institutions now have a suite of imaging tools to follow mouse models of human disease. Micro-ultrasound is one of these tools and is second after whole-mouse fluorescence or bioluminescent imaging, in terms of installed systems. We report in this paper the first commercially available array transducer-based ultrasound imaging system that enables micro-ultrasound imaging at center frequencies between 15 and 50 MHz. At the heart of the new scanner is a laser-machined high-frequency 256 element, linear transducer array capable of forming dynamic diffraction limited beams. The power of the linear array approach is embodied in the uniform high resolution maintained over the full field of view. This leads to greatly expanded scope for real-time functional imaging that is demonstrated in this paper. The unprecedented images made with the new imaging system will enable many new applications not previously possible. These include real-time visualization of flow in the mouse placenta, visualization of flow development in the embryo, studies of embryonic to adult cardiac development/disease, and studies of real-time blood flow in mouse models of tumour angiogenesis.

Entities:  

Mesh:

Year:  2009        PMID: 19647922     DOI: 10.1016/j.ultrasmedbio.2009.04.012

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  39 in total

1.  Quantitative estimates of the variability of in vivo sonographic measurements of the mouse aorta for studies of abdominal aortic aneurysms and related arterial diseases.

Authors:  Uchechukwu K Sampson; Prudhvidhar R Perati; Petra A Prins; Wellington Pham; Zhouwen Liu; Frank E Harrell; MacRae F Linton; John C Gore; Valentina Kon; Sergio Fazio
Journal:  J Ultrasound Med       Date:  2011-06       Impact factor: 2.153

2.  PMN-PT single-crystal high-frequency kerfless phased array.

Authors:  Ruimin Chen; Nestor E Cabrera-Munoz; Kwok Ho Lam; Hsiu-sheng Hsu; Fan Zheng; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-06       Impact factor: 2.725

3.  Measuring myofiber orientations from high-frequency ultrasound images using multiscale decompositions.

Authors:  Xulei Qin; Baowei Fei
Journal:  Phys Med Biol       Date:  2014-06-24       Impact factor: 3.609

4.  Functional and anatomical evidence of cerebral tissue hypoxia in young sickle cell anemia mice.

Authors:  Lindsay S Cahill; Lisa M Gazdzinski; Albert Ky Tsui; Yu-Qing Zhou; Sharon Portnoy; Elaine Liu; C David Mazer; Gregory Mt Hare; Andrea Kassner; John G Sled
Journal:  J Cereb Blood Flow Metab       Date:  2016-07-20       Impact factor: 6.200

5.  Analysis and Design of High-Frequency 1-D CMUT Imaging Arrays in Noncollapsed Mode.

Authors:  Evren Fatih Arkan; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-17       Impact factor: 2.725

6.  Micro-ultrasound for preclinical imaging.

Authors:  F Stuart Foster; John Hossack; S Lee Adamson
Journal:  Interface Focus       Date:  2011-06-08       Impact factor: 3.906

7.  Effect of microbubble size on fundamental mode high frequency ultrasound imaging in mice.

Authors:  Shashank Sirsi; Jameel Feshitan; James Kwan; Shunichi Homma; Mark Borden
Journal:  Ultrasound Med Biol       Date:  2010-05-05       Impact factor: 2.998

8.  Silencing of miR-195 reduces diabetic cardiomyopathy in C57BL/6 mice.

Authors:  Dong Zheng; Jian Ma; Yong Yu; Minghui Li; Rui Ni; Grace Wang; Ruizhen Chen; Jianmin Li; Guo-Chang Fan; James C Lacefield; Tianqing Peng
Journal:  Diabetologia       Date:  2015-05-21       Impact factor: 10.122

9.  A high-frequency linear ultrasonic array utilizing an interdigitally bonded 2-2 piezo-composite.

Authors:  Jonathan M Cannata; Jay A Williams; Lequan Zhang; Chang-Hong Hu; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-10       Impact factor: 2.725

10.  Probenecid as a noninjurious positive inotrope in an ischemic heart disease murine model.

Authors:  Sheryl E Koch; Michael Tranter; Nathan Robbins; Kristin Luther; Umesh Singh; Min Jiang; Xiaoping Ren; Trisha Tee; Leah Smith; Priyanka Varma; W Keith Jones; Jack Rubinstein
Journal:  J Cardiovasc Pharmacol Ther       Date:  2012-12-14       Impact factor: 2.457

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.