Literature DB >> 25510446

Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose.

Eun-Suk Cho1, Tae-Sub Chung, Sung Jun Ahn, KyoungHoon Chong, Jang Hun Baek, Sang Hyun Suh.   

Abstract

OBJECTIVES: To determine the feasibility of using a 70-kVp protocol compared with a 120-kVp protocol for cerebral CT angiography. An additional target was to investigate a possible reduction in the volume of contrast medium (CM) using the 70-kVp protocol.
METHODS: Attenuation value and CNR for iodine were determined at various tube voltage settings using a phantom. Sixty-nine volunteers were randomly assigned to one of three protocols: group A (120-kVp and CM 64 mL), group B (70-kVp and CM 64 mL), or group C (70-kVp and CM 40 mL). The attenuation value, SNR, and CNR of cerebral arteries, subjective image quality, and radiation dose were compared among the groups.
RESULTS: The vascular attenuation, SNR, and CNR of group B were significantly higher than those of group A. Group C had a significantly higher vascular attenuation than group A. Groups B and C were significantly better than group A with respect to subjective image quality. An effective dose of 70-kVp was 10 % lower than that of 120-kVp.
CONCLUSIONS: Using 70-kVp improved arterial enhancement, SNR, and CNR, and provided better subjective image quality, using a 10 % lower effective dose. Furthermore, the 70-kVp protocol may both reduce volume of CM by 37.5 % and improve arterial enhancement. KEY POINTS: • Cerebral CT angiography at 70-kVp substantially improved vascular enhancement • Subjective image quality was better at 70-kVp, with lower radiation dose • The volume of contrast media can be substantially reduced at 70-kVp.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25510446     DOI: 10.1007/s00330-014-3540-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  25 in total

1.  Technique factors and image quality as functions of patient weight at abdominal CT.

Authors:  W Huda; E M Scalzetti; G Levin
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

Review 2.  Contrast-induced nephropathy.

Authors:  Tadhg G Gleeson; Sudi Bulugahapitiya
Journal:  AJR Am J Roentgenol       Date:  2004-12       Impact factor: 3.959

3.  Low kilovoltage CT of the neck with 70 kVp: comparison with a standard protocol.

Authors:  R Gnannt; A Winklehner; R Goetti; B Schmidt; S Kollias; H Alkadhi
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

4.  Reduction of contrast material volume in 3D angiography of the brain using MDCT.

Authors:  Yoshitaka Tamura; Daisuke Utsunomiya; Takashi Sakamoto; Toshinori Hirai; Taiji Nishiharu; Joji Urata; Yasuyuki Yamashita
Journal:  AJR Am J Roentgenol       Date:  2010-08       Impact factor: 3.959

5.  CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings.

Authors:  Claudia Schueller-Weidekamm; Cornelia M Schaefer-Prokop; Michael Weber; Christian J Herold; Mathias Prokop
Journal:  Radiology       Date:  2006-12       Impact factor: 11.105

Review 6.  Pathophysiology of contrast-induced nephropathy.

Authors:  James Tumlin; Fulvio Stacul; Andy Adam; Christoph R Becker; Charles Davidson; Norbert Lameire; Peter A McCullough
Journal:  Am J Cardiol       Date:  2006-02-17       Impact factor: 2.778

7.  16-MDCT angiography in living kidney donors at various tube potentials: impact on image quality and radiation dose.

Authors:  Dushyant V Sahani; Sanjeeva P Kalva; Peter F Hahn; Sanjay Saini
Journal:  AJR Am J Roentgenol       Date:  2007-01       Impact factor: 3.959

8.  Diagnostic accuracy of pulmonary CT angiography at low tube voltage: intraindividual comparison of a normal-dose protocol at 120 kVp and a low-dose protocol at 80 kVp using reduced amount of contrast medium in a simulation study.

Authors:  Zsolt Szucs-Farkas; Fabian Schibler; Jennifer Cullmann; Jaled Charimo Torrente; Michael A Patak; Stephan Raible; Hanno Hoppe; Rolf Wyttenbach; Peter Vock; Sebastian T Schindera
Journal:  AJR Am J Roentgenol       Date:  2011-11       Impact factor: 3.959

9.  A simple risk score for prediction of contrast-induced nephropathy after percutaneous coronary intervention: development and initial validation.

Authors:  Roxana Mehran; Eve D Aymong; Eugenia Nikolsky; Zoran Lasic; Ioannis Iakovou; Martin Fahy; Gary S Mintz; Alexandra J Lansky; Jeffrey W Moses; Gregg W Stone; Martin B Leon; George Dangas
Journal:  J Am Coll Cardiol       Date:  2004-10-06       Impact factor: 24.094

10.  Thoracoabdominal-aortoiliac multidetector-row CT angiography at 80 and 100 kVp: assessment of image quality and radiation dose.

Authors:  Sebastian T Schindera; Patricia Graca; Michael A Patak; Susanne Abderhalden; Gabriel von Allmen; Peter Vock; Zsolt Szucs-Farkas
Journal:  Invest Radiol       Date:  2009-10       Impact factor: 6.016

View more
  7 in total

1.  Image quality, radiation dose and diagnostic accuracy of 70 kVp whole brain volumetric CT perfusion imaging: a preliminary study.

Authors:  Xiao Kun Fang; Qian Qian Ni; U Joseph Schoepf; Chang Sheng Zhou; Guo Zhong Chen; Song Luo; Stephen R Fuller; Carlo N De Cecco; Long Jiang Zhang; Guang Ming Lu
Journal:  Eur Radiol       Date:  2016-02-06       Impact factor: 5.315

2.  Reducing both radiation and contrast doses in coronary CT angiography in lean patients on a 16-cm wide-detector CT using 70 kVp and ASiR-V algorithm, in comparison with the conventional 100-kVp protocol.

Authors:  Yuhuan Chen; Zhentang Liu; Michelle Li; Yong Yu; Yongjun Jia; Guangming Ma; Zhijun Hu; DongHong Wei; Dou Li; Taiping He
Journal:  Eur Radiol       Date:  2018-11-30       Impact factor: 5.315

3.  Cerebral bone subtraction CT angiography using 80 kVp and sinogram-affirmed iterative reconstruction: contrast medium and radiation dose reduction with improvement of image quality.

Authors:  Yasunori Nagayama; Takeshi Nakaura; Akinori Tsuji; Joji Urata; Mitsuhiro Furusawa; Hideaki Yuki; Kenichiro Hirarta; Seitaro Oda; Masafumi Kidoh; Daisuke Utsunomiya; Yasuyuki Yamashita
Journal:  Neuroradiology       Date:  2017-01-03       Impact factor: 2.804

4.  Head and neck angiography at 70 kVp with a third-generation dual-source CT system in patients: comparison with 100 kVp.

Authors:  Yu Chen; Xiaobo Zhang; Huadan Xue; Yuanli Zhu; Yun Wang; Yumei Li; Zhuhua Zhang; Zhengyu Jin
Journal:  Neuroradiology       Date:  2017-08-24       Impact factor: 2.804

5.  CT pulmonary angiography: simultaneous low-pitch dual-source acquisition mode with 70 kVp and 40 ml of contrast medium and comparison with high-pitch spiral dual-source acquisition with automated tube potential selection.

Authors:  Johannes Boos; Patric Kröpil; Rotem S Lanzman; Joel Aissa; Christoph Schleich; Philipp Heusch; Lino M Sawicki; Gerald Antoch; Christoph Thomas
Journal:  Br J Radiol       Date:  2016-03-23       Impact factor: 3.039

6.  Possible Contrast Media Reduction with Low keV Monoenergetic Images in the Detection of Focal Liver Lesions: A Dual-Energy CT Animal Study.

Authors:  Yong Eun Chung; Je Sung You; Hye-Jeong Lee; Joon Seok Lim; Hye Sun Lee; Song-Ee Baek; Myeong-Jin Kim
Journal:  PLoS One       Date:  2015-07-23       Impact factor: 3.240

Review 7.  Low radiation dose in computed tomography: the role of iodine.

Authors:  Andrik J Aschoff; Carlo Catalano; Miles A Kirchin; Martin Krix; Thomas Albrecht
Journal:  Br J Radiol       Date:  2017-05-04       Impact factor: 3.039

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.