Literature DB >> 22021532

Diagnostic accuracy of pulmonary CT angiography at low tube voltage: intraindividual comparison of a normal-dose protocol at 120 kVp and a low-dose protocol at 80 kVp using reduced amount of contrast medium in a simulation study.

Zsolt Szucs-Farkas1, Fabian Schibler, Jennifer Cullmann, Jaled Charimo Torrente, Michael A Patak, Stephan Raible, Hanno Hoppe, Rolf Wyttenbach, Peter Vock, Sebastian T Schindera.   

Abstract

OBJECTIVE: The purpose of this study was to simulate pulmonary emboli (PE) and image quality at low tube energy and reduced contrast material volume in normal-dose pulmonary CT angiography (CTA) images and to analyze the diagnostic accuracy with normal- and low-dose pulmonary CTA.
MATERIALS AND METHODS: Normal-dose pulmonary CTA examinations using 120 kVp and 100 mL of contrast material in 10 patients with no PE were retrospectively selected. The image characteristics of an 80-kVp low-dose pulmonary CTA protocol (patient exposure reduction, 57%) with 75 mL of contrast material were simulated. Four different sets of filling defects were computer simulated in identical locations in each normal-dose and corresponding low-dose examination, equaling 783 PE in 40 normal-dose and 40 low-dose datasets. Ten normal-dose and 10 low-dose examinations contained no emboli and were used as controls. The 100 pulmonary CTA studies were randomly assessed by three readers blinded to PE location and image quality. The results were assessed by nonparametric tests and Student t tests.
RESULTS: No difference was found between the CT protocols in terms of sensitivity, specificity, and positive and negative diagnostic likelihood ratios at all ramification levels of the pulmonary arteries (p = 0.343-1). The overall sensitivity and specificity with the normal and simulated low-dose protocols were 79.9% versus 81.3% and 98.0% versus 98.2% (p = 0.444 and 0.702), respectively. The diagnostic confidence (2.81 ± 0.39 vs 2.77 ± 0.47; p = 0.297) and overall image quality (3.92 ± 0.52 vs 3.83 ± 0.54; p = 0.216) were similar at 120 kV and 80 kV.
CONCLUSION: The intraindividual comparison of diagnostic accuracy with normal-dose and simulated low-dose pulmonary CTA protocols revealed no difference under experimental conditions.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22021532     DOI: 10.2214/AJR.11.6750

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  16 in total

1.  Diagnosing venous thromboembolism in pregnancy.

Authors:  Thomas Grüning; Rebecca E Mingo; Matthew G Gosling; Sally L Farrell; Brent E Drake; Robert J Loader; Richard D Riordan
Journal:  Br J Radiol       Date:  2016-04-08       Impact factor: 3.039

2.  Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose.

Authors:  Eun-Suk Cho; Tae-Sub Chung; Sung Jun Ahn; KyoungHoon Chong; Jang Hun Baek; Sang Hyun Suh
Journal:  Eur Radiol       Date:  2014-12-16       Impact factor: 5.315

3.  90-kVp low-tube-voltage CT pulmonary angiography in combination with advanced modeled iterative reconstruction algorithm: effects on radiation dose, image quality and diagnostic accuracy for the detection of pulmonary embolism.

Authors:  Doris Leithner; Tatjana Gruber-Rouh; Martin Beeres; Julian L Wichmann; Scherwin Mahmoudi; Simon S Martin; Lukas Lenga; Moritz H Albrecht; Christian Booz; Thomas J Vogl; Jan-Erik Scholtz
Journal:  Br J Radiol       Date:  2018-06-05       Impact factor: 3.039

4.  Incidental findings detection using low tube potential for CT pulmonary angiography.

Authors:  Kanako K Kumamaru; Frank J Rybicki; Rachna Madan; Ritu Gill; Nicole Wake; Andetta R Hunsaker
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-01       Impact factor: 2.357

5.  Prospective randomised comparison of diagnostic confidence and image quality with normal-dose and low-dose CT pulmonary angiography at various body weights.

Authors:  Zsolt Szucs-Farkas; Boglarka Megyeri; Andreas Christe; Peter Vock; Johannes T Heverhagen; Sebastian T Schindera
Journal:  Eur Radiol       Date:  2014-05-28       Impact factor: 5.315

6.  Application of low-dose dual-source computed tomography angiography in children with complex congenital heart disease.

Authors:  Xian-Feng Chen; Fan Jiang; Lin Li; Yan Chen; Xin Chen; Yan-Yan Jiang; Li Xiang; Xiao-Jing Ma
Journal:  Exp Ther Med       Date:  2017-06-13       Impact factor: 2.447

Review 7.  Computed tomography of acute pulmonary embolism: state-of-the-art.

Authors:  Long Jiang Zhang; Guang Ming Lu; Felix G Meinel; Andrew D McQuiston; James G Ravenel; U Joseph Schoepf
Journal:  Eur Radiol       Date:  2015-03-13       Impact factor: 5.315

Review 8.  State-of-the-Art Imaging for the Evaluation of Pulmonary Embolism.

Authors:  Leonid Roshkovan; Harold Litt
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-08-07

9.  Geriatric chest imaging: when and how to image the elderly lung, age-related changes, and common pathologies.

Authors:  J Gossner; R Nau
Journal:  Radiol Res Pract       Date:  2013-07-01

10.  Diagnostic quality of CT pulmonary angiography in pulmonary thromboembolism: a comparison of three different kV values.

Authors:  Ömer Yılmaz; Esma Dilek Üstün; Mustafa Kayan; Fatmanur Kayan; Aykut Recep Aktaş; Elif Nisa Unlü; Bumin Değirmenci; Meltem Cetin
Journal:  Med Sci Monit       Date:  2013-10-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.