Reducing both radiation and contrast doses in coronary CT angiography in lean patients on a 16-cm wide-detector CT using 70 kVp and ASiR-V algorithm, in comparison with the conventional 100-kVp protocol.

Yuhuan Chen1,2, Zhentang Liu3, Michelle Li4, Yong Yu2, Yongjun Jia2, Guangming Ma2, Zhijun Hu3, DongHong Wei3, Dou Li3, Taiping He5,6.   

Abstract

OBJECTIVE: To investigate the value of prospectively ECG-triggered coronary CT angiography (CCTA) for lean patients with body mass index (BMI) ≤ 23 kg/m2 using 70 kVp and high-level volume-based adaptive statistical iterative reconstruction (ASiR-V) algorithm on a 16-cm wide-detector CT system for reducing both radiation and contrast doses in comparison with the conventional 100-kVp protocol.
MATERIALS AND METHODS: Thirty patients (group A) were prospectively enrolled to undergo 70-kVp CCTA on a 16-cm wide-detector CT scanner with noise index (NI) of 36 HU and at weight-dependent contrast dose rate of 16 mg I/kg/s for 9-s injection. Images were reconstructed with 80% ASiR-V. Radiation dose, contrast dose, and image quality were statistically compared with 30 patients (group B) in database with matching BMI who underwent conventional 100-kVp CCTA with NI of 25 HU, and at 25 mg I/kg/s rate for 10-s injection and reconstructed with 60% ASiR-V.
RESULTS: There was no significant difference in patient demographics between the two groups (all p > 0.05). The two groups also had similar mean CT values and contrast-noise ratio (CNR) and subjective image quality (all p > 0.05). However, group A with 70 kVp reduced the effective dose by 75.3% compared with group B (0.43 ± 0.20 mSv vs. 1.74 ± 1.01 mSv, p < 0.001), and required 42.4% less contrast dose than group B (22.46 ± 2.94 ml vs. 38.99 ± 5.10 ml, p < 0.001).
CONCLUSIONS: Prospectively ECG-triggered CCTA using 70 kVp and high-level ASiR-V on a 16-cm wide-detector CT system provides diagnostic images with substantial reduction in both radiation and contrast doses for patients with BMI ≤ 23 kg/m2 compared to the conventional 100-kVp protocol. KEY POINTS: • 70-kVp CCTA produces excellent images at sub-millisievert radiation. • 70-kVp CCTA reduces both radiation and contrast doses over conventional protocol. • Achieving low-dose CCTA with combined low kVp and high-level ASIR-V.

Entities:  

Keywords:  Computed tomography angiography; Contrast media; Coronary angiography; Radiation dosage

Mesh:

Substances:

Year:  2018        PMID: 30506217     DOI: 10.1007/s00330-018-5837-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  30 in total

1.  ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality.

Authors:  C Hong; C R Becker; A Huber; U J Schoepf; B Ohnesorge; A Knez; R Brüning; M F Reiser
Journal:  Radiology       Date:  2001-09       Impact factor: 11.105

2.  Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose.

Authors:  Eun-Suk Cho; Tae-Sub Chung; Sung Jun Ahn; KyoungHoon Chong; Jang Hun Baek; Sang Hyun Suh
Journal:  Eur Radiol       Date:  2014-12-16       Impact factor: 5.315

3.  CT coronary angiography: impact of adapted statistical iterative reconstruction (ASIR) on coronary stenosis and plaque composition analysis.

Authors:  Tobias A Fuchs; Michael Fiechter; Cathérine Gebhard; Julia Stehli; Jelena R Ghadri; Egle Kazakauskaite; Bernhard A Herzog; Lars Husmann; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2012-10-02       Impact factor: 2.357

4.  Image quality and radiation dose of lower extremity CT angiography at 70 kVp on an integrated circuit detector dual-source computed tomography.

Authors:  Li Qi; Yan'E Zhao; Chang Sheng Zhou; James V Spearman; Matthias Renker; U Joseph Schoepf; Long Jiang Zhang; Guang Ming Lu
Journal:  Acta Radiol       Date:  2014-06-11       Impact factor: 1.990

5.  Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience.

Authors:  Long Jiang Zhang; Li Qi; Jing Wang; Chun Xiang Tang; Chang Sheng Zhou; Xue Man Ji; James V Spearman; Carlo Nicola De Cecco; Felix G Meinel; U Joseph Schoepf; Guang Ming Lu
Journal:  Eur Radiol       Date:  2014-04-16       Impact factor: 5.315

6.  Coronary CT angiography for acute chest pain triage: techniques for radiation exposure reduction; 128 vs. 64 multidetector CT.

Authors:  Orly Goitein; Shlomi Matetzky; Yael Eshet; David Goitein; Ashraf Hamdan; Elio Di Segni; Eli Konen
Journal:  Acta Radiol       Date:  2011-08-12       Impact factor: 1.990

7.  Radiation dose and diagnostic accuracy of multidetector computed tomography for the detection of significant coronary artery stenoses: a meta-analysis.

Authors:  Gianluca Pontone; Daniele Andreini; Antonio L Bartorelli; Erika Bertella; Saima Mushtaq; Andrea Annoni; Alberto Formenti; Luisa Chiappa; Sarah Cortinovis; Andrea Baggiano; Edoardo Conte; Francesca Bovis; Fabrizio Veglia; Claudia Foti; Giovanni Ballerini; Cesare Fiorentini; Mauro Pepi
Journal:  Int J Cardiol       Date:  2011-10-05       Impact factor: 4.164

8.  Coronary artery disease: diagnostic accuracy of CT coronary angiography--a comparison of high and standard spatial resolution scanning.

Authors:  Gianluca Pontone; Erika Bertella; Saima Mushtaq; Monica Loguercio; Sarah Cortinovis; Andrea Baggiano; Edoardo Conte; Andrea Annoni; Alberto Formenti; Virginia Beltrama; Andrea Igoren Guaricci; Daniele Andreini
Journal:  Radiology       Date:  2014-02-08       Impact factor: 11.105

9.  Radiation reduction with prospective ECG-triggering acquisition using 64-multidetector Computed Tomographic angiography.

Authors:  Ambarish Gopal; Song S Mao; Daniel Karlsberg; Emily Young; Joshua Waggoner; Naser Ahmadi; Raveen S Pal; John Leal; Ronald P Karlsberg; Matthew J Budoff
Journal:  Int J Cardiovasc Imaging       Date:  2008-12-03       Impact factor: 2.357

10.  High-pitch coronary CT angiography at 70 kVp with low contrast medium volume: comparison of 80 and 100 kVp high-pitch protocols.

Authors:  Long Jiang Zhang; Li Qi; Carlo N De Cecco; Chang Sheng Zhou; James V Spearman; U Joseph Schoepf; Guang Ming Lu
Journal:  Medicine (Baltimore)       Date:  2014-11       Impact factor: 1.889

View more
  6 in total

1.  Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy.

Authors:  Woong Kyu Han; Joon Chae Na; Sung Yoon Park
Journal:  Eur Radiol       Date:  2019-08-30       Impact factor: 5.315

2.  Performance evaluation of using shorter contrast injection and 70 kVp with deep learning image reconstruction for reduced contrast medium dose and radiation dose in coronary CT angiography for children: a pilot study.

Authors:  Jihang Sun; Haoyan Li; Jianying Li; Yongli Cao; Zuofu Zhou; Michelle Li; Yun Peng
Journal:  Quant Imaging Med Surg       Date:  2021-09

3.  High-strength deep learning image reconstruction in coronary CT angiography at 70-kVp tube voltage significantly improves image quality and reduces both radiation and contrast doses.

Authors:  Wanjiang Li; Kaiyue Diao; Yuting Wen; Tao Shuai; Yongchun You; Jin Zhao; Kai Liao; Chunyan Lu; Jianqun Yu; Yong He; Zhenlin Li
Journal:  Eur Radiol       Date:  2022-01-21       Impact factor: 5.315

Review 4.  Network Medicine: A Clinical Approach for Precision Medicine and Personalized Therapy in Coronary Heart Disease.

Authors:  Teresa Infante; Luca Del Viscovo; Maria Luisa De Rimini; Sergio Padula; Pio Caso; Claudio Napoli
Journal:  J Atheroscler Thromb       Date:  2019-11-12       Impact factor: 4.928

Review 5.  A comprehensive review of imaging findings in COVID-19 - status in early 2021.

Authors:  Ali Afshar-Oromieh; Helmut Prosch; Cornelia Schaefer-Prokop; Karl Peter Bohn; Ian Alberts; Clemens Mingels; Majda Thurnher; Paul Cumming; Kuangyu Shi; Alan Peters; Silvana Geleff; Xiaoli Lan; Feng Wang; Adrian Huber; Christoph Gräni; Johannes T Heverhagen; Axel Rominger; Matthias Fontanellaz; Heiko Schöder; Andreas Christe; Stavroula Mougiakakou; Lukas Ebner
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-05-01       Impact factor: 9.236

6.  Influence of Contrast Agent Injection Scheme Customized by Dual-Source CT Based on Automatic Tube Voltage Technology on Image Quality and Radiation Dose of Coronary Artery Imaging.

Authors:  Weiling He; Xin Chen; Rui Hu; Wenjie Sun; Weili Tan
Journal:  Front Surg       Date:  2022-04-05
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.