Literature DB >> 21360584

Wear and migration of highly cross-linked and conventional cemented polyethylene cups with cobalt chrome or Oxinium femoral heads: a randomized radiostereometric study of 150 patients.

Thomas Kadar1, Geir Hallan, Arild Aamodt, Kari Indrekvam, Mona Badawy, Arne Skredderstuen, Leif Ivar Havelin, Terje Stokke, Kristin Haugan, Birgitte Espehaug, Ove Furnes.   

Abstract

This randomized study was performed to compare wear and migration of five different cemented total hip joint articulations in 150 patients. The patients received either a Charnley femoral stem with a 22.2 mm head or a Spectron EF femoral stem with a 28 mm head. The Charnley articulated with a γ-sterilized Charnley Ogee acetabular cup. The Spectron EF was used with either EtO-sterilized non-cross-linked polyethylene (Reflection All-Poly) or highly cross-linked (Reflection All-Poly XLPE) cups, combined with either cobalt chrome (CoCr) or Oxinium femoral heads. The patients were followed with repeated RSA measurements for 2 years. After 2 years, the EtO-sterilized non-cross-linked Reflection All-Poly cups had more than four times higher proximal penetration than its highly cross-linked counterpart. Use of Oxinium femoral heads did not affect penetration at 2 years compared to heads made of CoCr. Further follow-up is needed to evaluate the benefits, if any, of Oxinium femoral heads in the clinical setting. The Charnley Ogee was not outperformed by the more recently introduced implants in our study. We conclude that this prostheses still represents a standard against which new implants can be measured.
Copyright © 2011 Orthopaedic Research Society.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21360584     DOI: 10.1002/jor.21389

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  18 in total

1.  Early migration of the cemented tibial component of unicompartmental knee arthroplasty: a radiostereometry study.

Authors:  Andrea Ensini; Paolo Barbadoro; Alberto Leardini; Fabio Catani; Sandro Giannini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-04       Impact factor: 4.342

2.  Head material influences survival of a cemented total hip prosthesis in the Norwegian Arthroplasty Register.

Authors:  Thomas Kadar; Eva Dybvik; Geir Hallan; Ove Furnes; Leif Ivar Havelin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

3.  Do oxidized zirconium femoral heads reduce polyethylene wear in cemented THAs? A blinded randomized clinical trial.

Authors:  Amine Zaoui; Samer El Hage; Jean Langlois; Caroline Scemama; Jean Pierre Courpied; Moussa Hamadouche
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

Review 4.  [Tribology in hip arthroplasty : Benefits of different materials].

Authors:  J Philippe Kretzer; Maximilian Uhler; Sebastian Jäger; Therese Bormann; Robert Sonntag; Mareike Schonhoff; Stefan Schröder
Journal:  Orthopade       Date:  2021-02-25       Impact factor: 1.087

5.  Hip dislocation increases roughness of oxidized zirconium femoral heads in total hip arthroplasty: an analysis of 59 retrievals.

Authors:  Mohamed E Moussa; Christina I Esposito; Marcella E Elpers; Timothy M Wright; Douglas E Padgett
Journal:  J Arthroplasty       Date:  2014-11-11       Impact factor: 4.757

Review 6.  Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants.

Authors:  Charlotte Skjöldebrand; Joanne L Tipper; Peter Hatto; Michael Bryant; Richard M Hall; Cecilia Persson
Journal:  Mater Today Bio       Date:  2022-04-30

7.  A randomized study on migration of the Spectron EF and the Charnley flanged 40 cemented femoral components using radiostereometric analysis at 2 years.

Authors:  Thomas Kadar; Geir Hallan; Arild Aamodt; Kari Indrekvam; Mona Badawy; Leif Ivar Havelin; Terje Stokke; Kristin Haugan; Birgitte Espehaug; Ove Furnes
Journal:  Acta Orthop       Date:  2011-09-06       Impact factor: 3.717

Review 8.  Wear of highly crosslinked polyethylene acetabular components.

Authors:  Stuart A Callary; Lucian B Solomon; Oksana T Holubowycz; David G Campbell; Zachary Munn; Donald W Howie
Journal:  Acta Orthop       Date:  2014-10-10       Impact factor: 3.717

9.  Small and similar amounts of micromotion in an anatomical stem and a customized cementless femoral stem in regular-shaped femurs. A 5-year follow-up randomized RSA study.

Authors:  Mona Nysted; Olav A Foss; Jomar Klaksvik; Pål Benum; Kristin Haugan; Otto Schnell Husby; Arild Aamodt
Journal:  Acta Orthop       Date:  2014-04       Impact factor: 3.717

Review 10.  Total hip replacement for the treatment of end stage arthritis of the hip: a systematic review and meta-analysis.

Authors:  Alexander Tsertsvadze; Amy Grove; Karoline Freeman; Rachel Court; Samantha Johnson; Martin Connock; Aileen Clarke; Paul Sutcliffe
Journal:  PLoS One       Date:  2014-07-08       Impact factor: 3.240

View more