Literature DB >> 33692601

Zirconia-Toughened Alumina Coated Ti6Al4V via Additive Manufacturing.

Jose D Avila1, Amit Bandyopadhyay1.   

Abstract

CoCr alloy-based femoral heads have failed prematurely due to galvanic-induced corrosion when coupled with a titanium hip stem. Coupling a titanium based-femoral head with the titanium hip stem is ideal in addressing this failure mode. Ti6Al4V (Ti64) alloy was reinforced with zirconia-toughened alumina (ZTA) by directed-energy deposition (DED)-based additive manufacturing (AM) to address that concern. Preliminary materials processing work resulted in failed samples due to cracking, porosity, and delamination. After careful parameter optimization, a Ti64+5wt.%ZTA (5ZTA) composition produced a metallurgically sound and coherent interface, minimal porosity, and bulk structures. Hardness was observed to increase by 27%, normalized wear rate reduced by 25%, and contact resistance increased during in vitro tribological testing along with faster surface re-passivation.

Entities:  

Keywords:  Ti6Al4V; directed-energy deposition; load-bearing implants; surface modification; zirconia-toughened alumina

Year:  2021        PMID: 33692601      PMCID: PMC7939135          DOI: 10.1016/j.matlet.2021.129577

Source DB:  PubMed          Journal:  Mater Lett            Impact factor:   3.423


  8 in total

Review 1.  Corrosion of Metallic Biomaterials: A Review.

Authors:  Noam Eliaz
Journal:  Materials (Basel)       Date:  2019-01-28       Impact factor: 3.623

2.  Oxidized zirconium on ceramic; Catastrophic coupling.

Authors:  V E Ozden; N Saglam; G Dikmen; I R Tozun
Journal:  Orthop Traumatol Surg Res       Date:  2016-11-18       Impact factor: 2.256

3.  Direct in vivo inflammatory cell-induced corrosion of CoCrMo alloy orthopedic implant surfaces.

Authors:  Jeremy L Gilbert; Shiril Sivan; Yangping Liu; Sevi B Kocagöz; Christina M Arnholt; Steven M Kurtz
Journal:  J Biomed Mater Res A       Date:  2014-03-26       Impact factor: 4.396

4.  Fracture of a BIOLOX Delta Ceramic Femoral Head: A Case Report and Update of the Literature.

Authors:  Conor S Rankin; P G Robinson; N Beattie; P Gaston
Journal:  JBJS Case Connect       Date:  2019-12

Review 5.  Metal sensitivity in patients with orthopaedic implants.

Authors:  N Hallab; K Merritt; J J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2001-03       Impact factor: 5.284

6.  Hip dislocation increases roughness of oxidized zirconium femoral heads in total hip arthroplasty: an analysis of 59 retrievals.

Authors:  Mohamed E Moussa; Christina I Esposito; Marcella E Elpers; Timothy M Wright; Douglas E Padgett
Journal:  J Arthroplasty       Date:  2014-11-11       Impact factor: 4.757

7.  Additively Manufactured Ti6Al4V-Si-Hydroxyapatite composites for articulating surfaces of load-bearing implants.

Authors:  Jose D Avila; Zumurda Alrawahi; Susmita Bose; Amit Bandyopadhyay
Journal:  Addit Manuf       Date:  2020-04-23

8.  Primary hip replacement stem taper fracture due to corrosion in 3 patients.

Authors:  Michael M Morlock; Dennis Bünte; Harmen Ettema; Cees C Verheyen; Åke Hamberg; Jeremy Gilbert
Journal:  Acta Orthop       Date:  2016-01-11       Impact factor: 3.717

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.