Advanced wear of an Oxinium™ femoral head implant following polyethylene liner dislocation.

H Tribe1, S Malek, J Stammers, V Ranawat, J A Skinner.   

Abstract

Oxinium™ (Smith & Nephew, Memphis, TN, US) has been used in hip arthroplasty since 2003. The surface coating is hard and provides low wear rates but if this surface coating is damaged, the soft metal core is at risk of accelerated wear. Previous reports have described accelerated wear following intra and postoperative hip dislocation. We report a case of advanced wear of an in situ Oxinium™ femoral head implant following a cracked acetabular liner. The liner had disengaged from the titanium shell, allowing the Oxinium™ head to articulate directly with the shell. The disengaged liner led to dislocation of the Oxinium™ head, with associated pronounced wear of the head and the acetabular cup. The patient had a successful revision procedure. We advise close follow-up of patients with Oxinium™ implants, especially if associated with dislocation and closed reduction.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24165329      PMCID: PMC4311548          DOI: 10.1308/003588413X13629960047876

Source DB:  PubMed          Journal:  Ann R Coll Surg Engl        ISSN: 0035-8843            Impact factor:   1.891


  5 in total

1.  Differences in metal ion release following cobalt-chromium and oxidized zirconium total knee arthroplasty.

Authors:  Simon Garrett; Neal Jacobs; Piers Yates; Anne Smith; David Wood
Journal:  Acta Orthop Belg       Date:  2010-08       Impact factor: 0.500

2.  Damage of oxinium femoral heads subsequent to hip arthroplasty dislocation three retrieval case studies.

Authors:  Alan M Kop; Colin Whitewood; Don J L Johnston
Journal:  J Arthroplasty       Date:  2007-04-20       Impact factor: 4.757

3.  Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement. A prospective, randomized study.

Authors:  Young-Hoo Kim
Journal:  J Bone Joint Surg Am       Date:  2005-08       Impact factor: 5.284

4.  Comparison of mid-term clinical outcomes after primary total hip arthroplasty with Oxinium vs cobalt chrome femoral heads.

Authors:  Peter M Lewis; Christopher A Moore; Michael Olsen; Emil H Schemitsch; James P Waddell
Journal:  Orthopedics       Date:  2008-12       Impact factor: 1.390

5.  Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty.

Authors:  Kyung-Hoi Koo; Yong-Chan Ha; Woon Hwa Jung; Sang-Rim Kim; Jeong Joon Yoo; Hee Joong Kim
Journal:  J Bone Joint Surg Am       Date:  2008-02       Impact factor: 5.284

  5 in total
  4 in total

1.  Severe metallosis following oxidised zirconium wear in total hip arthroplasty.

Authors:  Erato Gkouliopoulou; Filon Agathangelidis; Themistoklis Vampertzis; Thomas Ntovas
Journal:  BMJ Case Rep       Date:  2016-10-31

2.  Hip dislocation increases roughness of oxidized zirconium femoral heads in total hip arthroplasty: an analysis of 59 retrievals.

Authors:  Mohamed E Moussa; Christina I Esposito; Marcella E Elpers; Timothy M Wright; Douglas E Padgett
Journal:  J Arthroplasty       Date:  2014-11-11       Impact factor: 4.757

3.  The Oxinium Arthrogram: A Sign of Oxidized Zirconium Implant Failure.

Authors:  Benjamin M Frye; Kelsey R Laughery; Adam E Klein
Journal:  Arthroplast Today       Date:  2021-03-07

Review 4.  Recent updates for biomaterials used in total hip arthroplasty.

Authors:  Chang Yong Hu; Taek-Rim Yoon
Journal:  Biomater Res       Date:  2018-12-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.