Literature DB >> 21357966

Damage of an Oxinium femoral head and polyethylene liner following 'routine' total hip replacement.

R W McCalden1, K D Charron, R D Davidson, M G Teeter, D W Holdsworth.   

Abstract

We present a case of early retrieval of an Oxinium femoral head and corresponding polyethylene liner where there was significant surface damage to the head and polyethylene. The implants were retrieved at the time of revision surgery to correct leg-length discrepancy just 48 hours after the primary hip replacement. Appropriate analysis of the retrieved femoral head demonstrated loss of the Oxinium layer with exposure of the underlying substrate and transfer of titanium from the acetabular shell at the time of a reduction of the index total hip replacement. In addition, the level of damage to the polyethylene was extensive despite only 48 hours in situ. The purpose of this report is to highlight the care that is required at the time of reduction, especially with these hard femoral counter-faces such as Oxinium. To our knowledge, the damage occurring at the time of reduction has not been previously reported following the retrieval of an otherwise well-functioning hip replacement.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21357966     DOI: 10.1302/0301-620X.93B3.25327

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  8 in total

1.  Distinctive damage patterns on THA metal bearing surfaces: case studies.

Authors:  Anneliese D Heiner; Nishant M Tikekar; Karen M Kruger; John J Lannutti; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2014

2.  Enhancing damage visibility on metallic bearing surfaces: a simple technique for photography and viewing.

Authors:  Anneliese D Heiner; Karen M Kruger; Thomas E Baer; Thomas D Brown
Journal:  J Arthroplasty       Date:  2013-01-18       Impact factor: 4.757

3.  CORR Insights®: Polyethylene Wear Increases in Liners Articulating With Scratched Oxidized Zirconium Femoral Heads.

Authors:  Matthew G Teeter
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

4.  Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years.

Authors:  Kevin L Garvin; Tyler C White; Anand Dusad; Curtis W Hartman; John Martell
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

5.  Hip dislocation increases roughness of oxidized zirconium femoral heads in total hip arthroplasty: an analysis of 59 retrievals.

Authors:  Mohamed E Moussa; Christina I Esposito; Marcella E Elpers; Timothy M Wright; Douglas E Padgett
Journal:  J Arthroplasty       Date:  2014-11-11       Impact factor: 4.757

Review 6.  Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants.

Authors:  Charlotte Skjöldebrand; Joanne L Tipper; Peter Hatto; Michael Bryant; Richard M Hall; Cecilia Persson
Journal:  Mater Today Bio       Date:  2022-04-30

7.  Polyethylene Wear Increases in Liners Articulating With Scratched Oxidized Zirconium Femoral Heads.

Authors:  Alberto Carli; Chelsea N Koch; Christina I Esposito; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

8.  Mid-term survivorship and clinical outcomes of cobalt-chrome and oxidized zirconium on highly crosslinked polyethylene.

Authors:  Stephen M Petis; Edward M Vasarhelyi; Brent A Lanting; James L Howard; Douglas D R Naudie; Lyndsay E Somerville; Richard W McCalden
Journal:  Can J Surg       Date:  2016-02       Impact factor: 2.089

  8 in total