Literature DB >> 25346367

Measuring renal tissue relaxation times at 7 T.

Xiufeng Li1, Patrick J Bolan, Kamil Ugurbil, Gregory J Metzger.   

Abstract

As developments in RF coils and RF management strategies make performing ultra-high-field renal imaging feasible, understanding the relaxation times of the tissue becomes increasingly important for tissue characterization, sequence optimization and quantitative functional renal imaging, such as renal perfusion imaging using arterial spin labeling. By using a magnetization-prepared single-breath-hold fast spin echo imaging method, human renal T1 and T2 imaging studies were successfully performed at 7 T with 11 healthy volunteers (eight males, 45 ± 17 years, and three females, 29 ± 7 years, mean ± standard deviation, S.D.) while addressing challenges of B1 (+) inhomogeneity and short-term specific absorption rate limits. At 7 T, measured renal T1 values for the renal cortex and medulla (mean ± S.D.) from five healthy volunteers who participated in both 3 T and two-session 7 T studies were 1661 ± 68 ms and 2094 ± 67 ms, and T2 values were 108 ± 7 ms and 126 ± 6 ms. For comparison, similar measurements were made at 3 T, where renal cortex and medulla T1 values of 1261 ± 86 ms and 1676 ± 94 ms and T2 values of 121 ± 5 ms and 138 ± 7 ms were obtained. Measurements at 3 T and 7 T were significantly different for both T1 and T2 values in both renal tissues. Reproducibility studies at 7 T demonstrated that T1 and T2 estimations were robust, with group mean percentage differences of less than 4%.
Copyright © 2014 John Wiley & Sons, Ltd.

Entities:  

Keywords:  7 T; kidneys; longitudinal relaxation time (T1); renal relaxation time; transverse relaxation time (T2); ultra-high field (UHF)

Mesh:

Year:  2014        PMID: 25346367      PMCID: PMC4335643          DOI: 10.1002/nbm.3195

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  37 in total

1.  7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images.

Authors:  J T Vaughan; M Garwood; C M Collins; W Liu; L DelaBarre; G Adriany; P Andersen; H Merkle; R Goebel; M B Smith; K Ugurbil
Journal:  Magn Reson Med       Date:  2001-07       Impact factor: 4.668

2.  The return of the frequency sweep: designing adiabatic pulses for contemporary NMR.

Authors:  M Garwood; L DelaBarre
Journal:  J Magn Reson       Date:  2001-12       Impact factor: 2.229

3.  FAIR true-FISP perfusion imaging of the kidneys.

Authors:  Petros Martirosian; Uwe Klose; Irina Mader; Fritz Schick
Journal:  Magn Reson Med       Date:  2004-02       Impact factor: 4.668

4.  Variable-rate selective excitation for rapid MRI sequences.

Authors:  Brian A Hargreaves; Charles H Cunningham; Dwight G Nishimura; Steven M Conolly
Journal:  Magn Reson Med       Date:  2004-09       Impact factor: 4.668

5.  MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: preliminary results.

Authors:  Cedric M J de Bazelaire; Guillaume D Duhamel; Neil M Rofsky; David C Alsop
Journal:  Radiology       Date:  2004-03       Impact factor: 11.105

6.  Single breath-hold T1 measurement using low flip angle TrueFISP.

Authors:  L Bokacheva; A J Huang; Q Chen; N Oesingmann; P Storey; H Rusinek; V S Lee
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

7.  SAR and power implications of different RF shimming strategies in the pelvis for 7T MRI.

Authors:  Bob van den Bergen; Cornelis A T van den Berg; Dennis W J Klomp; Jan J W Lagendijk
Journal:  J Magn Reson Imaging       Date:  2009-07       Impact factor: 4.813

8.  Ultra high spatial and temporal resolution breast imaging at 7T.

Authors:  B L van de Bank; I J Voogt; M Italiaander; B L Stehouwer; V O Boer; P R Luijten; D W J Klomp
Journal:  NMR Biomed       Date:  2012-10-18       Impact factor: 4.044

9.  The diagnostic value of renal cortex-to-medulla contrast on magnetic resonance images.

Authors:  F Terrier; H Hricak; E Justich; G C Dooms; W Grodd
Journal:  Eur J Radiol       Date:  1986-05       Impact factor: 3.528

10.  Renal corticomedullary differentiation: observation in patients with differing serum creatinine levels.

Authors:  R C Semelka; K Corrigan; S M Ascher; J J Brown; R E Colindres
Journal:  Radiology       Date:  1994-01       Impact factor: 11.105

View more
  8 in total

1.  High-resolution imaging of distinct human corpus callosum microstructure and topography of structural connectivity to cortices at high field.

Authors:  Byeong-Yeul Lee; Xiao-Hong Zhu; Xiufeng Li; Wei Chen
Journal:  Brain Struct Funct       Date:  2018-12-03       Impact factor: 3.270

2.  Prospective pediatric study comparing glomerular filtration rate estimates based on motion-robust dynamic contrast-enhanced magnetic resonance imaging and serum creatinine (eGFR) to 99mTc DTPA.

Authors:  Sila Kurugol; Onur Afacan; Richard S Lee; Catherine M Seager; Michael A Ferguson; Deborah R Stein; Reid C Nichols; Monet Dugan; Alto Stemmer; Simon K Warfield; Jeanne S Chow
Journal:  Pediatr Radiol       Date:  2020-01-27

3.  Quantitative single breath-hold renal arterial spin labeling imaging at 7T.

Authors:  Xiufeng Li; Edward J Auerbach; Pierre-Francois Van de Moortele; Kamil Ugurbil; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2017-05-09       Impact factor: 4.668

Review 4.  Progress in Imaging the Human Torso at the Ultrahigh Fields of 7 and 10.5 T.

Authors:  Kamil Uğurbil; Pierre-Francois Van de Moortele; Andrea Grant; Edward J Auerbach; Arcan Ertürk; Russell Lagore; Jutta M Ellermann; Xiaoxuan He; Gregor Adriany; Gregory J Metzger
Journal:  Magn Reson Imaging Clin N Am       Date:  2021-02       Impact factor: 2.266

5.  Stability and sensitivity of water T2 obtained with IDEAL-CPMG in healthy and fat-infiltrated skeletal muscle.

Authors:  Christopher D J Sinclair; Jasper M Morrow; Robert L Janiczek; Matthew R B Evans; Elham Rawah; Sachit Shah; Michael G Hanna; Mary M Reilly; Tarek A Yousry; John S Thornton
Journal:  NMR Biomed       Date:  2016-11-03       Impact factor: 4.044

6.  Magnetic resonance imaging T1- and T2-mapping to assess renal structure and function: a systematic review and statement paper.

Authors:  Marcos Wolf; Anneloes de Boer; Kanishka Sharma; Peter Boor; Tim Leiner; Gere Sunder-Plassmann; Ewald Moser; Anna Caroli; Neil Peter Jerome
Journal:  Nephrol Dial Transplant       Date:  2018-09-01       Impact factor: 5.992

Review 7.  Evolution of UHF Body Imaging in the Human Torso at 7T: Technology, Applications, and Future Directions.

Authors:  M Arcan Erturk; Xiufeng Li; Pierre-Fancois Van de Moortele; Kamil Ugurbil; Gregory J Metzger
Journal:  Top Magn Reson Imaging       Date:  2019-06

Review 8.  7 T renal MRI: challenges and promises.

Authors:  Anneloes de Boer; Johannes M Hoogduin; Peter J Blankestijn; Xiufeng Li; Peter R Luijten; Gregory J Metzger; Alexander J E Raaijmakers; Lale Umutlu; Fredy Visser; Tim Leiner
Journal:  MAGMA       Date:  2016-03-23       Impact factor: 2.310

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.