Literature DB >> 15334579

Variable-rate selective excitation for rapid MRI sequences.

Brian A Hargreaves1, Charles H Cunningham, Dwight G Nishimura, Steven M Conolly.   

Abstract

Balanced steady-state free precession (SSFP) imaging sequences require short repetition times (TRs) to avoid off-resonance artifacts. The use of slab-selective excitations is common, as this can improve imaging speed by limiting the field of view (FOV). However, the necessarily short-duration excitations have poor slab profiles. This results in unusable slices at the slab edge due to significant flip-angle variations or aliasing in the slab direction. Variable-rate selective excitation (VERSE) is a technique by which a time-varying gradient waveform is combined with a modified RF waveform to provide the same excitation profile with different RF power and duration characteristics. With the use of VERSE, it is possible to design short-duration pulses with dramatically improved slab profiles. These pulses achieve high flip angles with only minor off-resonance sensitivity, while meeting SAR limits at 1.5 T. The improved slab profiles will enable more rapid 3D imaging of limited volumes, with more consistent image contrast across the excited slab. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15334579     DOI: 10.1002/mrm.20168

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  52 in total

1.  High-resolution imaging of distinct human corpus callosum microstructure and topography of structural connectivity to cortices at high field.

Authors:  Byeong-Yeul Lee; Xiao-Hong Zhu; Xiufeng Li; Wei Chen
Journal:  Brain Struct Funct       Date:  2018-12-03       Impact factor: 3.270

2.  Noncontrast-enhanced three-dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition.

Authors:  Huimin Wu; Walter F Block; Patrick A Turski; Charles A Mistretta; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2012-04-24       Impact factor: 4.668

3.  7T bone perfusion imaging of the knee using arterial spin labeling MRI.

Authors:  Xiufeng Li; Casey P Johnson; Jutta Ellermann
Journal:  Magn Reson Med       Date:  2019-12-24       Impact factor: 4.668

4.  3D-MB-MUSE: A robust 3D multi-slab, multi-band and multi-shot reconstruction approach for ultrahigh resolution diffusion MRI.

Authors:  Iain P Bruce; Hing-Chiu Chang; Christopher Petty; Nan-Kuei Chen; Allen W Song
Journal:  Neuroimage       Date:  2017-07-18       Impact factor: 6.556

5.  3D dynamic MRI of the vocal tract during natural speech.

Authors:  Yongwan Lim; Yinghua Zhu; Sajan Goud Lingala; Dani Byrd; Shrikanth Narayanan; Krishna Shrinivas Nayak
Journal:  Magn Reson Med       Date:  2018-11-03       Impact factor: 4.668

6.  The separation of Gln and Glu in STEAM: a comparison study using short and long TEs/TMs at 3 and 7 T.

Authors:  Weiqiang Dou; Jörn Kaufmann; Meng Li; Kai Zhong; Martin Walter; Oliver Speck
Journal:  MAGMA       Date:  2015-01-08       Impact factor: 2.310

7.  High-fidelity, high-isotropic-resolution diffusion imaging through gSlider acquisition with B 1 + and T1 corrections and integrated ΔB0 /Rx shim array.

Authors:  Congyu Liao; Jason Stockmann; Qiyuan Tian; Berkin Bilgic; Nicolas S Arango; Mary Kate Manhard; Susie Y Huang; William A Grissom; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-08-01       Impact factor: 4.668

8.  Design of parallel transmission pulses for simultaneous multislice with explicit control for peak power and local specific absorption rate.

Authors:  Bastien Guérin; Kawin Setsompop; Huihui Ye; Benedikt A Poser; Andrew V Stenger; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-06-17       Impact factor: 4.668

9.  Simultaneous multislice excitation by parallel transmission.

Authors:  Benedikt A Poser; Robert James Anderson; Bastien Guérin; Kawin Setsompop; Weiran Deng; Azma Mareyam; Peter Serano; Lawrence L Wald; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2013-05-28       Impact factor: 4.668

10.  Three dimensional first-pass myocardial perfusion imaging at 3T: feasibility study.

Authors:  Taehoon Shin; Houchun H Hu; Gerald M Pohost; Krishna S Nayak
Journal:  J Cardiovasc Magn Reson       Date:  2008-12-11       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.