Literature DB >> 23076877

Ultra high spatial and temporal resolution breast imaging at 7T.

B L van de Bank1, I J Voogt, M Italiaander, B L Stehouwer, V O Boer, P R Luijten, D W J Klomp.   

Abstract

There is a need to obtain higher specificity in the detection of breast lesions using MRI. To address this need, Dynamic Contrast-Enhanced (DCE) MRI has been combined with other structural and functional MRI techniques. Unfortunately, owing to time constraints structural images at ultra-high spatial resolution can generally not be obtained during contrast uptake, whereas the relatively low spatial resolution of functional imaging (e.g. diffusion and perfusion) limits the detection of small lesions. To be able to increase spatial as well as temporal resolution simultaneously, the sensitivity of MR detection needs to increase as well as the ability to effectively accelerate the acquisition. The required gain in signal-to-noise ratio (SNR) can be obtained at 7T, whereas acceleration can be obtained with high-density receiver coil arrays. In this case, morphological imaging can be merged with DCE-MRI, and other functional techniques can be obtained at higher spatial resolution, and with less distortion [e.g. Diffusion Weighted Imaging (DWI)]. To test the feasibility of this concept, we developed a unilateral breast coil for 7T. It comprises a volume optimized dual-channel transmit coil combined with a 30-channel receive array coil. The high density of small coil elements enabled efficient acceleration in any direction to acquire ultra high spatial resolution MRI of close to 0.6 mm isotropic detail within a temporal resolution of 69 s, high spatial resolution MRI of 1.5 mm isotropic within an ultra high temporal resolution of 6.7 s and low distortion DWI at 7T, all validated in phantoms, healthy volunteers and a patient with a lesion in the right breast classified as Breast Imaging Reporting and Data System (BI-RADS) IV.
Copyright © 2012 John Wiley & Sons, Ltd.

Entities:  

Keywords:  Dynamic Contrast Enhancement; RF receive coils; RF transmit coils; breast; parallel imaging

Mesh:

Substances:

Year:  2012        PMID: 23076877     DOI: 10.1002/nbm.2868

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  17 in total

Review 1.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

2.  Diffusion-weighted imaging of breast tumours at 3 Tesla and 7 Tesla: a comparison.

Authors:  S Gruber; L Minarikova; K Pinker; O Zaric; M Chmelik; B Strasser; P Baltzer; T Helbich; S Trattnig; W Bogner
Journal:  Eur Radiol       Date:  2015-08-27       Impact factor: 5.315

3.  Dynamic contrast-enhanced and ultra-high-resolution breast MRI at 7.0 Tesla.

Authors:  Bertine L Stehouwer; Dennis W J Klomp; Maurice A A J van den Bosch; Mies A Korteweg; Kenneth G A Gilhuijs; Arjen J Witkamp; Paul J van Diest; Karel A F Houwert; Wybe J M van der Kemp; Peter R Luijten; W P Th M Mali; Wouter B Veldhuis
Journal:  Eur Radiol       Date:  2013-08-28       Impact factor: 5.315

4.  Clinical application of bilateral high temporal and spatial resolution dynamic contrast-enhanced magnetic resonance imaging of the breast at 7 T.

Authors:  K Pinker; W Bogner; P Baltzer; S Trattnig; S Gruber; O Abeyakoon; M Bernathova; O Zaric; P Dubsky; Z Bago-Horvath; M Weber; D Leithner; T H Helbich
Journal:  Eur Radiol       Date:  2013-12-05       Impact factor: 5.315

5.  Toward 7T breast MRI clinical study: safety assessment using simulation of heterogeneous breast models in RF exposure.

Authors:  Xin Li; Joseph V Rispoli
Journal:  Magn Reson Med       Date:  2018-09-14       Impact factor: 4.668

6.  Measuring renal tissue relaxation times at 7 T.

Authors:  Xiufeng Li; Patrick J Bolan; Kamil Ugurbil; Gregory J Metzger
Journal:  NMR Biomed       Date:  2014-10-23       Impact factor: 4.044

7.  A 32-channel receive array coil for bilateral breast imaging and spectroscopy at 7T.

Authors:  Romina Del Bosque; Jiaming Cui; Stephen Ogier; Sergey Cheshkov; Ivan E Dimitrov; Craig Malloy; Steven M Wright; Mary McDougall
Journal:  Magn Reson Med       Date:  2020-08-09       Impact factor: 4.668

8.  Structural Features of Europium(II)-Containing Cryptates That Influence Relaxivity.

Authors:  Chamika U Lenora; Fabio Carniato; Yimin Shen; Zahid Latif; E Mark Haacke; Philip D Martin; Mauro Botta; Matthew J Allen
Journal:  Chemistry       Date:  2017-08-22       Impact factor: 5.236

9.  Breast MRI at 7 Tesla with a bilateral coil and T1-weighted acquisition with robust fat suppression: image evaluation and comparison with 3 Tesla.

Authors:  Ryan Brown; Pippa Storey; Christian Geppert; KellyAnne McGorty; Ana Paula Klautau Leite; James Babb; Daniel K Sodickson; Graham C Wiggins; Linda Moy
Journal:  Eur Radiol       Date:  2013-07-30       Impact factor: 5.315

10.  Magnetic resonance imaging of soft tissue infection with iron oxide labeled granulocytes in a rat model.

Authors:  Hassina Baraki; Norman Zinne; Dirk Wedekind; Martin Meier; André Bleich; Silke Glage; Hans-Juergen Hedrich; Ingo Kutschka; Axel Haverich
Journal:  PLoS One       Date:  2012-12-07       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.