BACKGROUND: Current methods to estimate glomerular filtration rate (GFR) have shortcomings. Estimates based on serum creatinine are known to be inaccurate in the chronically ill and during acute changes in renal function. Gold standard methods such as inulin and 99mTc diethylenetriamine pentaacetic acid (DTPA) require blood or urine sampling and thus can be difficult to perform in children. Motion-robust radial volumetric interpolated breath-hold examination (VIBE) dynamic contrast-enhanced MRI represents a novel tool for estimating GFR that has not been validated in children.
OBJECTIVE: The purpose of our study was to determine the feasibility and accuracy of GFR measured by motion-robust radial VIBE dynamic contrast-enhanced MRI compared to estimates by serum creatinine (eGFR) and 99mTc DTPA in children.
MATERIALS AND METHODS: We enrolled children, 0-18 years of age, who were undergoing both a contrast-enhanced MRI and nuclear medicine 99mTc DTPA glomerular filtration rate (NM-GFR) within 2 weeks of each other. Enrolled children consented to an additional 6-min dynamic contrast-enhanced MRI scan using the motion-robust high spatiotemporal resolution prototype dynamic radial VIBE sequence (Siemens, Erlangen, Germany) at 3 tesla (T). The images were reconstructed offline with high temporal resolution (~3 s/volume) using compressed sensing image reconstruction including regularization in temporal dimension to improve image quality and reduce streaking artifacts. Images were then automatically post-processed using in-house-developed software. Post-processing steps included automatic segmentation of kidney parenchyma and aorta using convolutional neural network techniques and tracer kinetic model fitting using the Sourbron two-compartment model to calculate the MR-based GFR (MR-GFR). The NM-GFR was compared to MR-GFR and estimated GFR based on serum creatinine (eGFR) using Pearson correlation coefficient and Bland-Altman analysis.
RESULTS: Twenty-one children (7 female, 14 male) were enrolled between February 2017 and May 2018. Data from six of these children were not further analyzed because of deviations from the MRI protocol. Fifteen patients were analyzed (5 female, 10 male; average age 5.9 years); the method was technically feasible in all children. The results showed that the MR-GFR correlated with NM-GFR with a Pearson correlation coefficient (r-value) of 0.98. Bland-Altman analysis (i.e. difference of MR-GFR and NM-GFR versus mean of NM-GFR and MR-GFR) showed a mean difference of -0.32 and reproducibility coefficient of 18 with 95% confidence interval, and the coefficient of variation of 6.7% with values between -19 (-1.96 standard deviation) and 18 (+1.96 standard deviation). In contrast, serum creatinine compared with NM-GFR yielded an r-value of 0.73. Bland-Altman analysis (i.e. difference of eGFR and NM-GFR versus mean of NM-GFR and eGFR) showed a mean difference of 2.9 and reproducibility coefficient of 70 with 95% confidence interval, and the coefficient of variation of 25% with values between -67 (-1.96 standard deviation) and 73 (+1.96 standard deviation).
CONCLUSION: MR-GFR is a technically feasible and reliable method of measuring GFR when compared to the reference standard, NM-GFR by serum 99mTc DTPA, and MR-GFR is more reliable than estimates based on serum creatinine.

Entities:  

Keywords:  99mTc diethylenetriamine pentaacetic acid; Children; Dynamic contrast-enhanced magnetic resonance imaging; Glomerular filtration rate; Kidneys; Nuclear medicine; Renal function; Serum creatinine

Mesh:

Substances:

Year:  2020        PMID: 31984436      PMCID: PMC7153988          DOI: 10.1007/s00247-020-04617-0

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  29 in total

1.  Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla.

Authors:  Hanzhang Lu; Chekesha Clingman; Xavier Golay; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2004-09       Impact factor: 4.668

Review 2.  Measured GFR as a confirmatory test for estimated GFR.

Authors:  Lesley A Stevens; Andrew S Levey
Journal:  J Am Soc Nephrol       Date:  2009-10-15       Impact factor: 10.121

3.  Free-breathing radial 3D fat-suppressed T1-weighted gradient echo sequence: a viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration.

Authors:  Hersh Chandarana; Tobias K Block; Andrew B Rosenkrantz; Ruth P Lim; Danny Kim; David J Mossa; James S Babb; Berthold Kiefer; Vivian S Lee
Journal:  Invest Radiol       Date:  2011-10       Impact factor: 6.016

4.  Glomerular hyperfiltration in children with cancer: prevalence and a hypothesis.

Authors:  Neha S Kwatra; Holly J Meany; Sunil J Ghelani; David Zahavi; Nayan Pandya; Massoud Majd
Journal:  Pediatr Radiol       Date:  2016-11-03

5.  Glomerular filtration rate: assessment with dynamic contrast-enhanced MRI and a cortical-compartment model in the rabbit kidney.

Authors:  Laurence Annet; Laurent Hermoye; Frank Peeters; François Jamar; Jean-Paul Dehoux; Bernard E Van Beers
Journal:  J Magn Reson Imaging       Date:  2004-11       Impact factor: 4.813

6.  Limitations of creatinine as a filtration marker in glomerulopathic patients.

Authors:  O Shemesh; H Golbetz; J P Kriss; B D Myers
Journal:  Kidney Int       Date:  1985-11       Impact factor: 10.612

7.  Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and the Rutland-Patlak plot technique.

Authors:  Nils Hackstein; Jan Heckrodt; Wigbert S Rau
Journal:  J Magn Reson Imaging       Date:  2003-12       Impact factor: 4.813

Review 8.  Measurement and estimation of GFR in children and adolescents.

Authors:  George J Schwartz; Dana F Work
Journal:  Clin J Am Soc Nephrol       Date:  2009-10-09       Impact factor: 8.237

9.  Golden-angle radial sparse parallel MRI: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI.

Authors:  Li Feng; Robert Grimm; Kai Tobias Block; Hersh Chandarana; Sungheon Kim; Jian Xu; Leon Axel; Daniel K Sodickson; Ricardo Otazo
Journal:  Magn Reson Med       Date:  2013-10-18       Impact factor: 4.668

Review 10.  Renal safety of gadolinium-based contrast media in patients with chronic renal insufficiency.

Authors:  Elena Ledneva; Svetlana Karie; Vincent Launay-Vacher; Nicolas Janus; Gilbert Deray
Journal:  Radiology       Date:  2009-03       Impact factor: 11.105

View more
  4 in total

Review 1.  Quantitative renal magnetic resonance imaging: magnetic resonance urography.

Authors:  J Damien Grattan-Smith; Jeanne Chow; Sila Kurugol; Richard Alan Jones
Journal:  Pediatr Radiol       Date:  2022-01-13

2.  Learning the Regularization in DCE-MR Image Reconstruction for Functional Imaging of Kidneys.

Authors:  Aziz Koçanaoğullari; Cemre Ariyurek; Onur Afacan; Sila Kurugol
Journal:  IEEE Access       Date:  2021-12-30       Impact factor: 3.476

3.  Retrospective Distortion and Motion Correction for Free-Breathing DW-MRI of the Kidneys Using Dual-Echo EPI and Slice-to-Volume Registration.

Authors:  Jaume Coll-Font; Onur Afacan; Scott Hoge; Harsha Garg; Kumar Shashi; Bahram Marami; Ali Gholipour; Jeanne Chow; Simon Warfield; Sila Kurugol
Journal:  J Magn Reson Imaging       Date:  2020-12-31       Impact factor: 4.813

4.  Improving Automatic Renal Segmentation in Clinically Normal and Abnormal Paediatric DCE-MRI via Contrast Maximisation and Convolutional Networks for Computing Markers of Kidney Function.

Authors:  Hykoush Asaturyan; Barbara Villarini; Karen Sarao; Jeanne S Chow; Onur Afacan; Sila Kurugol
Journal:  Sensors (Basel)       Date:  2021-11-28       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.