Literature DB >> 11740891

The return of the frequency sweep: designing adiabatic pulses for contemporary NMR.

M Garwood1, L DelaBarre.   

Abstract

Frequency-modulated (FM) pulses that function according to adiabatic principles are becoming increasingly popular in many areas of NMR. Often adiabatic pulses can extend experimental capabilities and minimize annoying experimental imperfections. Here, adiabatic principles and some of the current methods used to create these pulses are considered. The classical adiabatic rapid passage, which is a fundamental element upon which all adiabatic pulses and sequences are based, is analyzed using vector models in different rotating frames of reference. Two methods to optimize adiabaticity are described, and ways to tailor modulation functions to best satisfy specific experimental needs are demonstrated. Finally, adiabatic plane rotation pulses and frequency-selective multiple spin-echo sequences are considered.

Mesh:

Year:  2001        PMID: 11740891     DOI: 10.1006/jmre.2001.2340

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  261 in total

1.  High-resolution imaging of distinct human corpus callosum microstructure and topography of structural connectivity to cortices at high field.

Authors:  Byeong-Yeul Lee; Xiao-Hong Zhu; Xiufeng Li; Wei Chen
Journal:  Brain Struct Funct       Date:  2018-12-03       Impact factor: 3.270

2.  Composite RF pulses for B1+-insensitive volume excitation at 7 Tesla.

Authors:  Jay Moore; Marcin Jankiewicz; Huairen Zeng; Adam W Anderson; John C Gore
Journal:  J Magn Reson       Date:  2010-04-10       Impact factor: 2.229

3.  In vivo proton MR spectroscopy of pancreatic neuroendocrine tumors in a multiple endocrine neoplasia type 1 conditional knockout mouse model.

Authors:  Min-Hui Cui; Craig A Branch; Sean M Cahill; Thomas J Quinn; Asha Adem; Steven K Libutti; Ziqiang Yuan
Journal:  Magn Reson Med       Date:  2014-11-13       Impact factor: 4.668

Review 4.  MR spectroscopy and spectroscopic imaging of the brain.

Authors:  He Zhu; Peter B Barker
Journal:  Methods Mol Biol       Date:  2011

5.  Venous oxygenation mapping using velocity-selective excitation and arterial nulling.

Authors:  Jia Guo; Eric C Wong
Journal:  Magn Reson Med       Date:  2012-01-31       Impact factor: 4.668

6.  In vivo monitoring of recovery from neurodegeneration in conditional transgenic SCA1 mice.

Authors:  Gülin Oz; Manda L Vollmers; Christopher D Nelson; Ryan Shanley; Lynn E Eberly; Harry T Orr; H Brent Clark
Journal:  Exp Neurol       Date:  2011-09-22       Impact factor: 5.330

7.  Detecting Fleeting MRI Signals with Frequency-Modulated Pulses.

Authors:  Naoharu Kobayashi; Djaudat Idiyatullin; Curtis Corum; Steen Moeller; Ryan Chamberlain; Robert O'Connell; Donald R Nixdorf; Michael Garwood
Journal:  AIP Conf Proc       Date:  2011-03-29

8.  Feasibility of single-voxel MRS measurement of apparent diffusion coefficient of water in breast tumors.

Authors:  C A Corum; A D McIntosh; P J Bolan; M Nelson; A L Snyder; N J Powell; J Boyum; T H Emory; D Yee; T M Tuttle; L I Everson; M Garwood
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

9.  MRI contrasts in high rank rotating frames.

Authors:  Timo Liimatainen; Hanne Hakkarainen; Silvia Mangia; Janne M J Huttunen; Christine Storino; Djaudat Idiyatullin; Dennis Sorce; Michael Garwood; Shalom Michaeli
Journal:  Magn Reson Med       Date:  2014-02-12       Impact factor: 4.668

10.  Effect of Carr-Purcell refocusing pulse trains on transverse relaxation times of metabolites in rat brain at 9.4 Tesla.

Authors:  Dinesh Kumar Deelchand; Pierre-Gilles Henry; Małgorzata Marjańska
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.