Literature DB >> 25338110

Porous titanium construct cup compared to porous coated titanium cup in total hip arthroplasty. A randomised controlled trial.

Mats Salemyr1, Olle Muren, Thomas Eisler, Henrik Bodén, Ghazi Chammout, André Stark, Olof Sköldenberg.   

Abstract

PURPOSE: The purpose of this study was to determine if a new titanium cup with increased porosity resulted in different periacetabular bone loss and migration compared to a porous coated cup.
METHODS: Fifty-one patients with primary hip osteoarthritis were randomized to either a cup with porous titanium construct backside (porous titanium group, n = 25) or a conventional porous coated titanium cup (control group, n = 26). The primary outcome variable was change in periacetabular bone mineral density two years after surgery measured with dual energy X-ray absorptiometry (DXA). Secondary outcomes were implant fixation measured with radiostereometry (RSA) and clinical outcome scores.
RESULTS: The pattern of bone remodelling was similar in the two groups with almost complete restoration to baseline values. BMD diminished in the two proximal zones and increased in the two distal zones. After minimal migration up to six months all implants in both groups became stable. We found no difference between the two groups in clinical outcome scores.
CONCLUSIONS: In this prospective, randomized, controlled trial on a new porous titanium cup we found, compared to the control group, no clinically relevant differences regarding periacetabular bone preservation, implant fixation or clinical outcome up to two years postoperatively.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25338110     DOI: 10.1007/s00264-014-2571-z

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  27 in total

1.  Measuring bone mineral density of the pelvis and proximal femur after total hip arthroplasty.

Authors:  J M Wilkinson; N F Peel; R A Elson; I Stockley; R Eastell
Journal:  J Bone Joint Surg Br       Date:  2001-03

Review 2.  EQ-5D: a measure of health status from the EuroQol Group.

Authors:  R Rabin; F de Charro
Journal:  Ann Med       Date:  2001-07       Impact factor: 4.709

3.  Changes in bone mineral density in the proximal femur after cementless total hip arthroplasty. A five-year longitudinal study.

Authors:  W Brodner; P Bitzan; F Lomoschitz; P Krepler; R Jankovsky; S Lehr; F Kainberger; F Gottsauner-Wolf
Journal:  J Bone Joint Surg Br       Date:  2004-01

4.  Periacetabular cortical and cancellous bone mineral density loss after press-fit cup fixation: a prospective 7-year follow-up.

Authors:  Rainer Schmidt; Alexander Michael Kress; Melanie Nowak; Raimund Forst; Tobias Eckhard Nowak; Lutz Arne Mueller
Journal:  J Arthroplasty       Date:  2012-01-05       Impact factor: 4.757

5.  Different loss of BMD using uncemented press-fit and whole polyethylene cups fixed with cement: repeated DXA studies in 96 hips randomized to 3 types of fixation.

Authors:  Georgios Digas; Johan Kärrholm; Jonas Thanner
Journal:  Acta Orthop       Date:  2006-04       Impact factor: 3.717

6.  RSA wear measurements with or without markers in total hip arthroplasty.

Authors:  Niclas Börlin; Stephan M Röhrl; Charles R Bragdon
Journal:  J Biomech       Date:  2005-06-28       Impact factor: 2.712

7.  Bone loss around a stable, partly threaded hydroxyapatite-coated cup: a prospective cohort study using RSA and DXA.

Authors:  Stergios Lazarinis; Jan Milbrink; Per Mattsson; Hans Mallmin; Nils P Hailer
Journal:  Hip Int       Date:  2014-02-03       Impact factor: 2.135

8.  Structural and cellular assessment of bone quality of proximal femur.

Authors:  L D Dorr; M C Faugere; A M Mackel; T A Gruen; B Bognar; H H Malluche
Journal:  Bone       Date:  1993 May-Jun       Impact factor: 4.398

9.  Changes in bone mineral density of the acetabulum, femoral neck and femoral shaft, after hip resurfacing and total hip replacement: two-year results from a randomised study.

Authors:  J O Penny; K Brixen; J E Varmarken; O Ovesen; S Overgaard
Journal:  J Bone Joint Surg Br       Date:  2012-08

10.  Female patients with low systemic BMD are prone to bone loss in Gruen zone 7 after cementless total hip arthroplasty.

Authors:  Jessica J Alm; Tatu J Mäkinen; Petteri Lankinen; Niko Moritz; Tero Vahlberg; Hannu T Aro
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

View more
  10 in total

1.  Vitamin-E diffused highly cross-linked polyethylene liner compared to standard liners in total hip arthroplasty. A randomized, controlled trial.

Authors:  Mats Salemyr; Olle Muren; Torbjörn Ahl; Henrik Bodén; Ghazi Chammout; André Stark; Olof Sköldenberg
Journal:  Int Orthop       Date:  2015-01-29       Impact factor: 3.075

2.  Mid-term migration of a cementless, porous acetabular cup: A 5 year Radiostereometric analysis.

Authors:  Kjell G Nilsson; Annika Theodoulou; Graham Mercer; Stephen J Quinn; Jeganath Krishnan
Journal:  J Orthop       Date:  2017-07-21

3.  Osteoblastic cell response on high-rough titanium coatings by cold spray.

Authors:  A M Vilardell; N Cinca; N Garcia-Giralt; S Dosta; I G Cano; X Nogués; J M Guilemany
Journal:  J Mater Sci Mater Med       Date:  2018-02-01       Impact factor: 3.896

4.  Objective evaluation for initial stability of highly porous cup without screws in total hip arthroplasty for femoral neck fracture.

Authors:  Hideo Kobayashi; Yasuhiro Homma; Hiroki Tanabe; Taiji Watari; Hironori Ochi; Sammy Banno; Tomonori Baba; Kazuo Kaneko
Journal:  J Orthop       Date:  2019-08-10

5.  Inferior stabilization of cementless compared with cemented dual-mobility cups in elderly osteoarthrosis patients: a randomized controlled radiostereometry study on 60 patients with 2 years' follow-up.

Authors:  Steffan Tabori-Jensen; Sebastian Breddam Mosegaard; Torben B Hansen; Maiken Stilling
Journal:  Acta Orthop       Date:  2020-02-06       Impact factor: 3.717

6.  Higher early proximal migration of hemispherical cups with electrochemically applied hydroxyapatite (BoneMaster) on a porous surface compared with porous surface alone: a randomized RSA study with 53 patients.

Authors:  Peter Bo Jørgensen; Henrik Daugaard; Stig Storgaard Jakobsen; Martin Lamm; Kjeld Søballe; Maiken Stilling
Journal:  Acta Orthop       Date:  2019-11-08       Impact factor: 3.717

7.  The Use of Porous Titanium Coating and the Largest Possible Head Do Not Affect Early Cup Fixation: A 2-Year Report from a Randomized Controlled Trial.

Authors:  Georgios Tsikandylakis; Kristian R L Mortensen; Kirill Gromov; Anders Troelsen; Henrik Malchau; Maziar Mohaddes
Journal:  JB JS Open Access       Date:  2020-12-15

8.  Ceramic-on-ceramic articulation in press-fit total hip arthroplasty as a potential reason for early failure, what about the survivors: a ten year follow-up.

Authors:  J van Loon; A M J S Vervest; H M van der Vis; I N Sierevelt; D C Baas; K T M Opdam; G M M J Kerkhoffs; D Haverkamp
Journal:  Int Orthop       Date:  2021-01-18       Impact factor: 3.075

9.  Denosumab prevents acetabular bone loss around an uncemented cup: analysis of secondary outcomes in a randomized controlled trial.

Authors:  Demostenis Kiritopoulos; Andreas Nyström; Gösta Ullmark; Jens Sörensen; Marianne Petrén-Mallmin; Jan Milbrink; Nils P Hailer; Hans Mallmin
Journal:  Acta Orthop       Date:  2022-09-07       Impact factor: 3.925

10.  Migration and head penetration of Vitamin-E diffused cemented polyethylene cup compared to standard cemented cup in total hip arthroplasty: study protocol for a randomised, double-blind, controlled trial (E1 HIP).

Authors:  Olof Sköldenberg; Agata Rysinska; Ghazi Chammout; Mats Salemyr; Olle Muren; Henrik Bodén; Thomas Eisler
Journal:  BMJ Open       Date:  2016-07-07       Impact factor: 2.692

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.