Literature DB >> 15990104

RSA wear measurements with or without markers in total hip arthroplasty.

Niclas Börlin1, Stephan M Röhrl, Charles R Bragdon.   

Abstract

Novel algorithms for radiostereometric (RSA) measurements of the femoral head and metal-backed, hemi-spherical cups of a total hip replacement are presented and evaluated on phantom images and clinical double examinations of 20 patients. The materials were analysed with classical RSA and three novel algorithms: (1) a dual-projection head algorithm using the outline of the femoral head together with markers in the cup; (2) a marker-less algorithm based on measurements of the outline of the femoral head, the cup shell and opening circle of the cup; and (3) a combination of both methods. The novel algorithms improve current, marker-based, RSA measurements, as well as allows studies without marked cups. This opens the possibility of performing wear measurements on larger group of patients, in clinical follow-ups, even retrospective studies. The novel algorithms may help to save patient data in current RSA studies lost due to insufficiently marked cups. Finally, the novel algorithms simplify the RSA procedure and allow new studies without markers, saving time, money, and reducing safety concerns. Other potential uses include migration measurements of re-surfacing heads and measuring spherical sections as implant landmarks instead of markers.

Entities:  

Mesh:

Year:  2005        PMID: 15990104     DOI: 10.1016/j.jbiomech.2005.05.004

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  24 in total

1.  Precision and accuracy measurement of radiostereometric analysis applied to movement of the sacroiliac joint.

Authors:  Thomas J Kibsgård; Olav Røise; Britt Stuge; Stephan M Röhrl
Journal:  Clin Orthop Relat Res       Date:  2012-06-14       Impact factor: 4.176

2.  Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.

Authors:  David C Ayers; Meridith Greene; Benjamin Snyder; Michelle Aubin; Jacob Drew; Charles Bragdon
Journal:  J Bone Joint Surg Am       Date:  2015-04-15       Impact factor: 5.284

3.  Fixation and bone remodeling around a low stiffness stem in revision surgery.

Authors:  Johan Kärrholm; Reza Razaznejad
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

4.  Accuracy of model-based RSA contour reduction in a typical clinical application.

Authors:  Christof Hurschler; Frank Seehaus; Judith Emmerich; Bart L Kaptein; Henning Windhagen
Journal:  Clin Orthop Relat Res       Date:  2008-05-29       Impact factor: 4.176

5.  Case report: Cementless stem stabilization after intraoperative fracture: a radiostereometric analysis.

Authors:  David Campbell; Graham Mercer; Kjell G Nilsson; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2009-09-17       Impact factor: 4.176

6.  Porous titanium construct cup compared to porous coated titanium cup in total hip arthroplasty. A randomised controlled trial.

Authors:  Mats Salemyr; Olle Muren; Thomas Eisler; Henrik Bodén; Ghazi Chammout; André Stark; Olof Sköldenberg
Journal:  Int Orthop       Date:  2014-10-22       Impact factor: 3.075

7.  Vitamin-E diffused highly cross-linked polyethylene liner compared to standard liners in total hip arthroplasty. A randomized, controlled trial.

Authors:  Mats Salemyr; Olle Muren; Torbjörn Ahl; Henrik Bodén; Ghazi Chammout; André Stark; Olof Sköldenberg
Journal:  Int Orthop       Date:  2015-01-29       Impact factor: 3.075

8.  Wear of a 5 megarad cross-linked polyethylene liner: a 6-year RSA study.

Authors:  Stuart A Callary; David G Campbell; Graham Mercer; Kjell G Nilsson; John R Field
Journal:  Clin Orthop Relat Res       Date:  2013-01-19       Impact factor: 4.176

9.  Analysis of polyethylene wear in plain radiographs.

Authors:  Maiken Stilling; Kjeld Søballe; Niels Trolle Andersen; Kristian Larsen; Ole Rahbek
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

10.  The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures.

Authors:  Lucian B Solomon; Aaron W Stevenson; Stuart A Callary; Thomas R Sullivan; Donald W Howie; Mellick J Chehade
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.