Periacetabular cortical and cancellous bone mineral density loss after press-fit cup fixation: a prospective 7-year follow-up.

Rainer Schmidt1, Alexander Michael Kress, Melanie Nowak, Raimund Forst, Tobias Eckhard Nowak, Lutz Arne Mueller.   

Abstract

The impact of total hip arthroplasty on strain adaptive bone remodeling has been extensively analyzed by dual-energy x-ray absorptiometry. In this study, we present a prospective computed tomography-assisted study of periacetabular cortical and cancellous bone mineral density (in milligrams of calcium hydroxyapatite [CaHA] per milliliter, or mgCaHA/mL) changes 10 days and 1, 3, and 7 years after press-fit cup implantation for 38 hips in vivo. Cancellous bone mineral density decreased by Ø -63% ventral and Ø -85% dorsal to the cup; cortical bone mineral density, by Ø -22% ventral and Ø -18% dorsal to the cup. The presented periacetabular strain adaptive bone mineral density data are the most extensive of the current literature. Even the measured extensive cancellous bone mineral density loss was thus far of no clinical relevance because all cups showed radiographic signs of stable ingrowth.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22226614     DOI: 10.1016/j.arth.2011.09.031

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  Porous titanium construct cup compared to porous coated titanium cup in total hip arthroplasty. A randomised controlled trial.

Authors:  Mats Salemyr; Olle Muren; Thomas Eisler; Henrik Bodén; Ghazi Chammout; André Stark; Olof Sköldenberg
Journal:  Int Orthop       Date:  2014-10-22       Impact factor: 3.075

2.  No superior performance of hydroxyapatite-coated acetabular cups over porous-coated cups.

Authors:  Kestutis Valancius; Kjeld Søballe; Poul T Nielsen; Mogens B Laursen
Journal:  Acta Orthop       Date:  2013-10-31       Impact factor: 3.717

3.  Intra- and inter-observer agreement and reliability of bone mineral density measurements around acetabular cup: a porcine ex-vivo study using single- and dual-energy computed tomography.

Authors:  Bo Mussmann; Søren Overgaard; Trine Torfing; Morten Bøgehøj; Oke Gerke; Poul Erik Andersen
Journal:  Acta Radiol Open       Date:  2017-07-14

4.  Bone density measurements adjacent to acetabular cups in total hip arthroplasty using dual-energy CT: an in vivo reliability and agreement study.

Authors:  Bo Mussmann; Poul Erik Andersen; Trine Torfing; Søren Overgaard
Journal:  Acta Radiol Open       Date:  2018-08-30

5.  Long-term follow-up of a low profile, coated, press-fit cup: the trabeculae oriented pattern (T.O.P.) acetabular system.

Authors:  L Mosconi; L Cavagnaro; A Zanirato; E Quarto; M Lontaro Baracchini; M Formica
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-03-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.