Literature DB >> 16752282

Different loss of BMD using uncemented press-fit and whole polyethylene cups fixed with cement: repeated DXA studies in 96 hips randomized to 3 types of fixation.

Georgios Digas1, Johan Kärrholm, Jonas Thanner.   

Abstract

BACKGROUND: In cemented THA, aseptic loosening of the cup is more common than loosening of the stem, while periprosthetic osteolysis of the socket resulting in difficult reconstruction problems has emerged as the most significant problem with cementless cup fixation. PATIENTS AND METHODS: 90 patients (96 hips) scheduled for THA were stratified in three groups according to the method of fixation of the acetabular component: acrylic bone cement with fluoride (Cemex-F), porous-coated press-fit cup with ceramic coating (Trilogy, uncemented) and acrylic cement with gentamicin (Palacos). All patients received the Spectron EF stem. Acetabular bone mineral density was measured with dual-energy X-ray absorptiometry (DXA) 1 week postoperatively, and after 12 and 24 months. The periprosthetic BMD was evaluated in 5 ROIs positioned around the acetabular component.
RESULTS: In the uncemented sockets, the BMD had decreased proximally and medially to the cup after 2 years. The difference was significant in the proximal region as compared to the control group (Palacos). No difference was noted between the 2 groups with cemented components after 2 years. Stepwise linear regression analysis showed that loss of periprosthetic BMD in the proximal high-pressure region after 2 years increased with higher postoperative BMD and when the uncemented design had been used.
INTERPRETATION: Contrary to previous studies of cemented stems, the use of fluoride cement did not influence the periprosthetic BMD 2 years after the examination. Increased loss of BMD with use of uncemented press-fit cups in the region in which osteolytic lesions are commonly found suggests that stress shielding may initiate the development of this complication. Longer follow-up will, however, be necessary to substantiate this hypothesis.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16752282     DOI: 10.1080/17453670610045948

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  14 in total

1.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Retroacetabular stress-shielding in THA.

Authors:  Rocco P Pitto; Akanksha Bhargava; Salil Pandit; Jacob T Munro
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

Review 3.  Is there evidence for a superior method of socket fixation in hip arthroplasty? A systematic review.

Authors:  Dean Pakvis; Gijs van Hellemondt; Enrico de Visser; Wilco Jacobs; Maarten Spruit
Journal:  Int Orthop       Date:  2011-03-15       Impact factor: 3.075

4.  Porous titanium construct cup compared to porous coated titanium cup in total hip arthroplasty. A randomised controlled trial.

Authors:  Mats Salemyr; Olle Muren; Thomas Eisler; Henrik Bodén; Ghazi Chammout; André Stark; Olof Sköldenberg
Journal:  Int Orthop       Date:  2014-10-22       Impact factor: 3.075

Review 5.  Acrylic bone cement: current concept review.

Authors:  B Magnan; M Bondi; T Maluta; E Samaila; L Schirru; C Dall'Oca
Journal:  Musculoskelet Surg       Date:  2013-07-27

6.  Inferior stabilization of cementless compared with cemented dual-mobility cups in elderly osteoarthrosis patients: a randomized controlled radiostereometry study on 60 patients with 2 years' follow-up.

Authors:  Steffan Tabori-Jensen; Sebastian Breddam Mosegaard; Torben B Hansen; Maiken Stilling
Journal:  Acta Orthop       Date:  2020-02-06       Impact factor: 3.717

7.  Effects of hydroxyapatite coating of cups used in hip revision arthroplasty.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2012-09-03       Impact factor: 3.717

8.  Increased risk of revision of acetabular cups coated with hydroxyapatite.

Authors:  Stergios Lazarinis; Johan Kärrholm; Nils P Hailer
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

9.  Reverse hybrid and cemented hip replacement compared using radiostereometry and dual-energy X-ray absorptiometry: 43 hips followed for 2 years in a prospective trial.

Authors:  Einar Lindalen; Jon Dahl; Lars Nordsletten; Finnur Snorrason; Øystein Høvik; Stephan Röhrl
Journal:  Acta Orthop       Date:  2012-11-01       Impact factor: 3.717

10.  Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density. A 2-year RSA and 8-year radiographic follow-up study of 34 patients.

Authors:  Sami Finnilä; Niko Moritz; Erkki SvedströM; Jessica J Alm; Hannu T Aro
Journal:  Acta Orthop       Date:  2015-11-16       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.