Literature DB >> 25631687

Vitamin-E diffused highly cross-linked polyethylene liner compared to standard liners in total hip arthroplasty. A randomized, controlled trial.

Mats Salemyr1, Olle Muren, Torbjörn Ahl, Henrik Bodén, Ghazi Chammout, André Stark, Olof Sköldenberg.   

Abstract

PURPOSE: We hypothesized that a vitamin E-treated polyethylene articulating liner had lower femoral head penetration than a conventional liner.
METHODS: Fifty-one patients with primary hip osteoarthritis were randomized to an uncemented cup with either vitamin E-treated highly cross-linked polyethylene (HXLPE) (vitamin-e group, n = 25) or a standard HXLPE liner (control group, n = 26) and followed for two years after surgery. The outcome variable was polyethylene (PE) linear head penetration, measured with radiostereometry (RSA).
RESULTS: The head penetration in x- (medial/lateral) and y- (vertical) axes was significantly lower for the vitamin E-treated liner up to two years with a mean difference between the groups of 0.10 mm (95 % CI 0.04-0.18) and 0.08 mm (95 % CI 0.01-0.15), respectively. The initial total penetration was lower for the vitamin-E group but did not reach statistical significance at two years with a mean difference between the groups of 0.07 mm (95 % CI -0.001 to 0.15, p = 0.09). We found no differences in clinical outcome between the groups.
CONCLUSIONS: In this prospective, randomized, controlled trial on a new vitamin-E diffused HXLPE liner we found, compared to a conventional HXLPE liner, lower initial head penetration and lower superior and medial wear. A longer follow-up than two years is necessary to demonstrate lower overall head penetration in vitamin-E liners compared to contemporary highly cross-linked PE.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25631687     DOI: 10.1007/s00264-015-2680-3

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  14 in total

1.  Analysis of temporal wear patterns of porous-coated acetabular components: distinguishing between true wear and so-called bedding-in.

Authors:  C J Sychterz; C A Engh; A Yang; C A Engh
Journal:  J Bone Joint Surg Am       Date:  1999-06       Impact factor: 5.284

Review 2.  EQ-5D: a measure of health status from the EuroQol Group.

Authors:  R Rabin; F de Charro
Journal:  Ann Med       Date:  2001-07       Impact factor: 4.709

3.  Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements.

Authors:  H McKellop; F W Shen; B Lu; P Campbell; R Salovey
Journal:  J Orthop Res       Date:  1999-03       Impact factor: 3.494

4.  Wear of a 5 megarad cross-linked polyethylene liner: a 6-year RSA study.

Authors:  Stuart A Callary; David G Campbell; Graham Mercer; Kjell G Nilsson; John R Field
Journal:  Clin Orthop Relat Res       Date:  2013-01-19       Impact factor: 4.176

5.  RSA wear measurements with or without markers in total hip arthroplasty.

Authors:  Niclas Börlin; Stephan M Röhrl; Charles R Bragdon
Journal:  J Biomech       Date:  2005-06-28       Impact factor: 2.712

Review 6.  Vitamin E diffused, highly crosslinked UHMWPE: a review.

Authors:  Ebru Oral; Orhun K Muratoglu
Journal:  Int Orthop       Date:  2010-12-01       Impact factor: 3.075

7.  Structural and cellular assessment of bone quality of proximal femur.

Authors:  L D Dorr; M C Faugere; A M Mackel; T A Gruen; B Bognar; H H Malluche
Journal:  Bone       Date:  1993 May-Jun       Impact factor: 4.398

8.  Poor outcome of the PCA and Harris-Galante hip prostheses. Randomized study of 171 arthroplasties with 9-year follow-up.

Authors:  J Thanner; J Kärrholm; H Malchau; P Herberts
Journal:  Acta Orthop Scand       Date:  1999-04

9.  Guidelines for standardization of radiostereometry (RSA) of implants.

Authors:  Edward R Valstar; Richie Gill; Leif Ryd; Gunnar Flivik; Niclas Börlin; Johan Kärrholm
Journal:  Acta Orthop       Date:  2005-08       Impact factor: 3.717

10.  CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials.

Authors:  Kenneth F Schulz; Douglas G Altman; David Moher
Journal:  BMJ       Date:  2010-03-23
View more
  12 in total

1.  Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial.

Authors:  Caroline Scemama; Philippe Anract; Valérie Dumaine; Antoine Babinet; Jean Pierre Courpied; Moussa Hamadouche
Journal:  Int Orthop       Date:  2016-11-04       Impact factor: 3.075

2.  Reasons for Revision, Oxidation, and Damage Mechanisms of Retrieved Vitamin E-Stabilized Highly Crosslinked Polyethylene in Total Knee Arthroplasty.

Authors:  Hannah Spece; Jaclyn T Schachtner; Daniel W MacDonald; Gregg R Klein; Michael A Mont; Gwo-Chin Lee; Steven M Kurtz
Journal:  J Arthroplasty       Date:  2019-07-18       Impact factor: 4.757

3.  Ten to fifteen-year clinical and radiographic follow-up with a third-generation cementless stem in a young patient population.

Authors:  Peteris Studers; Danils Belajevs; Vitolds Jurkevics; Peteris Likums
Journal:  Int Orthop       Date:  2015-07-30       Impact factor: 3.075

4.  Implant survival of 2,723 vitamin E-infused highly crosslinked polyethylene liners in total hip arthroplasty: data from the Finnish Arthroplasty Register.

Authors:  Matias Hemmilä; Inari Laaksonen; Markus Matilainen; Antti Eskelinen; Jaason Haapakoski; Ari-Pekka Puhto; Jukka Kettunen; Konsta Pamilo; Keijo T Mäkelä
Journal:  Acta Orthop       Date:  2021-02-01       Impact factor: 3.717

Review 5.  Effectiveness of Vitamin-E-Doped Polyethylene in Joint Replacement: A Literature Review.

Authors:  Antonio Gigante; Carlo Bottegoni; Vincenza Ragone; Lorenzo Banci
Journal:  J Funct Biomater       Date:  2015-09-08

Review 6.  Ultra-High Molecular Weight Polyethylene: Influence of the Chemical, Physical and Mechanical Properties on the Wear Behavior. A Review.

Authors:  Pierangiola Bracco; Anuj Bellare; Alessandro Bistolfi; Saverio Affatato
Journal:  Materials (Basel)       Date:  2017-07-13       Impact factor: 3.623

7.  Aseptic loosening after total hip arthroplasty and the risk of cardiovascular disease: A nested case-control study.

Authors:  Agata Rysinska; Olof Sköldenberg; Anne Garland; Ola Rolfson; Sara Aspberg; Thomas Eisler; Göran Garellick; Andreas Stark; Nils Hailer; Max Gordon
Journal:  PLoS One       Date:  2018-11-14       Impact factor: 3.240

8.  Migration and head penetration of Vitamin-E diffused cemented polyethylene cup compared to standard cemented cup in total hip arthroplasty: study protocol for a randomised, double-blind, controlled trial (E1 HIP).

Authors:  Olof Sköldenberg; Agata Rysinska; Ghazi Chammout; Mats Salemyr; Olle Muren; Henrik Bodén; Thomas Eisler
Journal:  BMJ Open       Date:  2016-07-07       Impact factor: 2.692

9.  Vitamin E-doped total hip arthroplasty liners show similar head penetration to highly cross-linked polyethylene at five years: a multi-arm randomized controlled trial.

Authors:  Kristian Kjærgaard; Ming Ding; Carsten Jensen; Charles Bragdon; Henrik Malchau; Christina M Andreasen; Ole Ovesen; Christian Hofbauer; Søren Overgaard
Journal:  Bone Joint J       Date:  2020-10       Impact factor: 5.082

10.  2-year results of an RCT of 2 uncemented isoelastic monoblock acetabular components: lower wear rate with vitamin E blended highly cross-linked polyethylene compared to ultra-high molecular weight polyethylene.

Authors:  Joost H J van Erp; Julie R A Massier; Jelle J Halma; Thom E Snijders; Arthur de Gast
Journal:  Acta Orthop       Date:  2020-02-26       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.