Literature DB >> 25328638

Generalized Least-Squares CT Reconstruction with Detector Blur and Correlated Noise Models.

J Webster Stayman1, Wojciech Zbijewski1, Steven Tilley1, Jeffrey Siewerdsen1.   

Abstract

The success and improved dose utilization of statistical reconstruction methods arises, in part, from their ability to incorporate sophisticated models of the physics of the measurement process and noise. Despite the great promise of statistical methods, typical measurement models ignore blurring effects, and nearly all current approaches make the presumption of independent measurements - disregarding noise correlations and a potential avenue for improved image quality. In some imaging systems, such as flat-panel-based cone-beam CT, such correlations and blurs can be a dominant factor in limiting the maximum achievable spatial resolution and noise performance. In this work, we propose a novel regularized generalized least-squares reconstruction method that includes models for both system blur and correlated noise in the projection data. We demonstrate, in simulation studies, that this approach can break through the traditional spatial resolution limits of methods that do not model these physical effects. Moreover, in comparison to other approaches that attempt deblurring without a correlation model, superior noise-resolution trade-offs can be found with the proposed approach.

Entities:  

Keywords:  Sinogram restoration; correlated noise; crosstalk; high-resolution cone-beam computed tomography; model-based iterative reconstruction; projection deblurring

Year:  2014        PMID: 25328638      PMCID: PMC4201055          DOI: 10.1117/12.2043067

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  9 in total

1.  Maximum-likelihood transmission image reconstruction for overlapping transmission beams.

Authors:  D F Yu; J A Fessler; E P Ficaro
Journal:  IEEE Trans Med Imaging       Date:  2000-11       Impact factor: 10.048

2.  Distance-driven projection and backprojection in three dimensions.

Authors:  Bruno De Man; Samit Basu
Journal:  Phys Med Biol       Date:  2004-06-07       Impact factor: 3.609

3.  Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT.

Authors:  Bing Feng; Jeffrey A Fessler; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2006-07       Impact factor: 10.048

4.  Penalized-likelihood sinogram restoration for computed tomography.

Authors:  Patrick J La Rivière; Junguo Bian; Phillip A Vargas
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

5.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

6.  Statistical image reconstruction from correlated data with applications to PET.

Authors:  Adam Alessio; Ken Sauer; Paul Kinahan
Journal:  Phys Med Biol       Date:  2007-10-01       Impact factor: 3.609

7.  Adaptive statistical iterative reconstruction and Veo: assessment of image quality and diagnostic performance in CT colonography at various radiation doses.

Authors:  Min A Yoon; Se Hyung Kim; Jeong Min Lee; Hyoun Sik Woo; Eun Sun Lee; Se Jin Ahn; Joon Koo Han
Journal:  J Comput Assist Tomogr       Date:  2012 Sep-Oct       Impact factor: 1.826

8.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

Review 9.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

  9 in total
  5 in total

1.  Iterative CT Reconstruction using Models of Source and Detector Blur and Correlated Noise.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Conf Proc Int Conf Image Form Xray Comput Tomogr       Date:  2014

2.  Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation.

Authors:  Grace J Gang; J Webster Stayman; Wojciech Zbijewski; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

3.  Deformable image registration with local rigidity constraints for cone-beam CT-guided spine surgery.

Authors:  S Reaungamornrat; A S Wang; A Uneri; Y Otake; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2014-06-17       Impact factor: 3.609

4.  Statistical reconstruction for cone-beam CT with a post-artifact-correction noise model: application to high-quality head imaging.

Authors:  H Dang; J W Stayman; A Sisniega; J Xu; W Zbijewski; X Wang; D H Foos; N Aygun; V E Koliatsos; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2015-07-30       Impact factor: 3.609

5.  Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Phys Med Biol       Date:  2015-12-09       Impact factor: 3.609

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.