Literature DB >> 16827494

Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT.

Bing Feng1, Jeffrey A Fessler, Michael A King.   

Abstract

In order to reconstruct attenuation maps with improved spatial resolution and quantitative accuracy, we developed an approximate method of incorporating system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission reconstruction. Our method approximately models the blur caused by the finite intrinsic detector resolution, the nonideal source collimation and detector collimation. We derived the formulation using the optimization transfer principle as in the derivation of the OSTR algorithm. The formulation includes one forward-blur step and one back-blur step, which do not severely slow down reconstruction. The formulation could be applicable to various transmission geometries, such as point-source, line-source, and sheet-source systems. Through computer simulations of the MCAT phantom and transmission measurements of the air-filled Data Spectrum Deluxe single photo emission computed tomography (SPECT) Phantom on a system which employed a cone-beam geometry and a system which employed a scanning-line-source geometry, we showed that incorporation of RC increased spatial resolution and improved the quantitative accuracy of reconstruction. In simulation studies, attenuation maps reconstructed with RC correction improved the quantitative accuracy of emission reconstruction.

Entities:  

Mesh:

Year:  2006        PMID: 16827494     DOI: 10.1109/tmi.2006.876151

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  9 in total

1.  Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging.

Authors:  Steven Tilley; Matthew Jacobson; Qian Cao; Michael Brehler; Alejandro Sisniega; Wojciech Zbijewski; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

2.  Iterative CT Reconstruction using Models of Source and Detector Blur and Correlated Noise.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Conf Proc Int Conf Image Form Xray Comput Tomogr       Date:  2014

3.  Nonlinear Statistical Reconstruction for Flat-Panel Cone-Beam CT with Blur and Correlated Noise Models.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; Wojciech Zbijewski; J Webster Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-22

4.  Generalized Least-Squares CT Reconstruction with Detector Blur and Correlated Noise Models.

Authors:  J Webster Stayman; Wojciech Zbijewski; Steven Tilley; Jeffrey Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19

5.  Blind deconvolution in model-based iterative reconstruction for CT using a normalized sparsity measure.

Authors:  Lorenz Hehn; Steven Tilley; Franz Pfeiffer; J Webster Stayman
Journal:  Phys Med Biol       Date:  2019-10-31       Impact factor: 3.609

6.  PIRPLE: a penalized-likelihood framework for incorporation of prior images in CT reconstruction.

Authors:  J Webster Stayman; Hao Dang; Yifu Ding; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2013-10-10       Impact factor: 3.609

7.  Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Phys Med Biol       Date:  2015-12-09       Impact factor: 3.609

Review 8.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

9.  Nonlinear dual reconstruction of SPECT activity and attenuation images.

Authors:  Huafeng Liu; Min Guo; Zhenghui Hu; Pengcheng Shi; Hongjie Hu
Journal:  PLoS One       Date:  2014-09-16       Impact factor: 3.240

  9 in total