Statistical reconstruction for cone-beam CT with a post-artifact-correction noise model: application to high-quality head imaging.

H Dang1, J W Stayman, A Sisniega, J Xu, W Zbijewski, X Wang, D H Foos, N Aygun, V E Koliatsos, J H Siewerdsen.   

Abstract

Non-contrast CT reliably detects fresh blood in the brain and is the current front-line imaging modality for intracranial hemorrhage such as that occurring in acute traumatic brain injury (contrast ~40-80 HU, size  >  1 mm). We are developing flat-panel detector (FPD) cone-beam CT (CBCT) to facilitate such diagnosis in a low-cost, mobile platform suitable for point-of-care deployment. Such a system may offer benefits in the ICU, urgent care/concussion clinic, ambulance, and sports and military theatres. However, current FPD-CBCT systems face significant challenges that confound low-contrast, soft-tissue imaging. Artifact correction can overcome major sources of bias in FPD-CBCT but imparts noise amplification in filtered backprojection (FBP). Model-based reconstruction improves soft-tissue image quality compared to FBP by leveraging a high-fidelity forward model and image regularization. In this work, we develop a novel penalized weighted least-squares (PWLS) image reconstruction method with a noise model that includes accurate modeling of the noise characteristics associated with the two dominant artifact corrections (scatter and beam-hardening) in CBCT and utilizes modified weights to compensate for noise amplification imparted by each correction. Experiments included real data acquired on a FPD-CBCT test-bench and an anthropomorphic head phantom emulating intra-parenchymal hemorrhage. The proposed PWLS method demonstrated superior noise-resolution tradeoffs in comparison to FBP and PWLS with conventional weights (viz. at matched 0.50 mm spatial resolution, CNR = 11.9 compared to CNR = 5.6 and CNR = 9.9, respectively) and substantially reduced image noise especially in challenging regions such as skull base. The results support the hypothesis that with high-fidelity artifact correction and statistical reconstruction using an accurate post-artifact-correction noise model, FPD-CBCT can achieve image quality allowing reliable detection of intracranial hemorrhage.

Entities:  

Mesh:

Year:  2015        PMID: 26225912      PMCID: PMC4545529          DOI: 10.1088/0031-9155/60/16/6153

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  41 in total

1.  Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter.

Authors:  J H Siewerdsen; D A Jaffray
Journal:  Med Phys       Date:  2001-02       Impact factor: 4.071

2.  Penalized-likelihood sinogram restoration for computed tomography.

Authors:  Patrick J La Rivière; Junguo Bian; Phillip A Vargas
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

3.  Cone-beam volumetric tomography for applications in the temporal bone.

Authors:  Richard T Penninger; Tanya S Tavassolie; John P Carey
Journal:  Otol Neurotol       Date:  2011-04       Impact factor: 2.311

4.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

5.  Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation.

Authors:  Grace J Gang; J Webster Stayman; Wojciech Zbijewski; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

6.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

7.  CT arthrography of the wrist using a novel, mobile, dedicated extremity cone-beam CT (CBCT).

Authors:  Seppo K Koskinen; Ville V Haapamäki; Jari Salo; Nina C Lindfors; Mika Kortesniemi; Lauri Seppälä; Kimmo T Mattila
Journal:  Skeletal Radiol       Date:  2012-09-19       Impact factor: 2.199

8.  Generalized Least-Squares CT Reconstruction with Detector Blur and Correlated Noise Models.

Authors:  J Webster Stayman; Wojciech Zbijewski; Steven Tilley; Jeffrey Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19

9.  PIRPLE: a penalized-likelihood framework for incorporation of prior images in CT reconstruction.

Authors:  J Webster Stayman; Hao Dang; Yifu Ding; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2013-10-10       Impact factor: 3.609

10.  Accelerating ordered subsets image reconstruction for X-ray CT using spatially nonuniform optimization transfer.

Authors:  Donghwan Kim; Debashish Pal; Jean-Baptiste Thibault; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2013-06-07       Impact factor: 10.048

View more
  9 in total

1.  Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging.

Authors:  Steven Tilley; Matthew Jacobson; Qian Cao; Michael Brehler; Alejandro Sisniega; Wojciech Zbijewski; J Webster Stayman
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

Review 2.  Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

Authors:  Hao Zhang; Jing Wang; Dong Zeng; Xi Tao; Jianhua Ma
Journal:  Med Phys       Date:  2018-09-10       Impact factor: 4.071

3.  Task-Based Regularization Design for Detection of Intracranial Hemorrhage in Cone-Beam CT.

Authors:  H Dang; J W Stayman; J Xu; A Sisniega; W Zbijewski; X Wang; D H Foos; N Aygun; V E Koliatsos; J H Siewerdsen
Journal:  Conf Proc Int Conf Image Form Xray Comput Tomogr       Date:  2016-07

4.  Low-Dose CT Perfusion of the Liver using Reconstruction of Difference.

Authors:  Saeed Seyyedi; Eleni Liapi; Tobias Lasser; Robert Ivkov; Rajeev Hatwar; J Webster Stayman
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-03-05

5.  Multi-resolution statistical image reconstruction for mitigation of truncation effects: application to cone-beam CT of the head.

Authors:  Hao Dang; J Webster Stayman; Alejandro Sisniega; Wojciech Zbijewski; Jennifer Xu; Xiaohui Wang; David H Foos; Nafi Aygun; Vassilis E Koliatsos; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-12-29       Impact factor: 3.609

6.  Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise.

Authors:  Steven Tilley; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Phys Med Biol       Date:  2015-12-09       Impact factor: 3.609

7.  Prospective regularization design in prior-image-based reconstruction.

Authors:  Hao Dang; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Phys Med Biol       Date:  2015-11-25       Impact factor: 3.609

Review 8.  Technical Principles of Dual-Energy Cone Beam Computed Tomography and Clinical Applications for Radiation Therapy.

Authors:  Shailaja Sajja; Young Lee; Markus Eriksson; Håkan Nordström; Arjun Sahgal; Masoud Hashemi; James G Mainprize; Mark Ruschin
Journal:  Adv Radiat Oncol       Date:  2019-07-30

9.  Truncation effect reduction for fast iterative reconstruction in cone-beam CT.

Authors:  Sorapong Aootaphao; Saowapak S Thongvigitmanee; Puttisak Puttawibul; Pairash Thajchayapong
Journal:  BMC Med Imaging       Date:  2022-09-05       Impact factor: 2.795

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.