Literature DB >> 17921576

Statistical image reconstruction from correlated data with applications to PET.

Adam Alessio1, Ken Sauer, Paul Kinahan.   

Abstract

Most statistical reconstruction methods for emission tomography are designed for data modeled as conditionally independent Poisson variates. In reality, due to scanner detectors, electronics and data processing, correlations are introduced into the data resulting in dependent variates. In general, these correlations are ignored because they are difficult to measure and lead to computationally challenging statistical reconstruction algorithms. This work addresses the second concern, seeking to simplify the reconstruction of correlated data and provide a more precise image estimate than the conventional independent methods. In general, correlated variates have a large non-diagonal covariance matrix that is computationally challenging to use as a weighting term in a reconstruction algorithm. This work proposes two methods to simplify the use of a non-diagonal covariance matrix as the weighting term by (a) limiting the number of dimensions in which the correlations are modeled and (b) adopting flexible, yet computationally tractable, models for correlation structure. We apply and test these methods with simple simulated PET data and data processed with the Fourier rebinning algorithm which include the one-dimensional correlations in the axial direction and the two-dimensional correlations in the transaxial directions. The methods are incorporated into a penalized weighted least-squares 2D reconstruction and compared with a conventional maximum a posteriori approach.

Mesh:

Year:  2007        PMID: 17921576      PMCID: PMC2597017          DOI: 10.1088/0031-9155/52/20/004

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  21 in total

1.  Quantitative comparison of FBP, EM, and Bayesian reconstruction algorithms for the IndyPET scanner.

Authors:  Thomas Frese; Ned C Rouze; Charles A Bouman; Ken Sauer; Gary D Hutchins
Journal:  IEEE Trans Med Imaging       Date:  2003-02       Impact factor: 10.048

2.  High-resolution PET detector design: modelling components of intrinsic spatial resolution.

Authors:  Jennifer R Stickel; Simon R Cherry
Journal:  Phys Med Biol       Date:  2005-01-21       Impact factor: 3.609

3.  Analytical reconstruction of deconvolved Fourier rebinned PET sinograms.

Authors:  Adam Alessio; Ken Sauer; Paul Kinahan
Journal:  Phys Med Biol       Date:  2005-12-15       Impact factor: 3.609

4.  A generalized Gaussian image model for edge-preserving MAP estimation.

Authors:  C Bouman; K Sauer
Journal:  IEEE Trans Image Process       Date:  1993       Impact factor: 10.856

5.  Penalized weighted least-squares image reconstruction for positron emission tomography.

Authors:  J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

6.  Algebraic reconstruction techniques can be made computationally efficient [positron emission tomography application].

Authors:  G T Herman; L B Meyer
Journal:  IEEE Trans Med Imaging       Date:  1993       Impact factor: 10.048

7.  Energy-selective reconstructions in X-ray computerized tomography.

Authors:  R E Alvarez; A Macovski
Journal:  Phys Med Biol       Date:  1976-09       Impact factor: 3.609

8.  Weighted least-squares reconstruction methods for positron emission tomography.

Authors:  J M Anderson; B A Mair; M Rao; C H Wu
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

9.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography.

Authors:  R Gordon; R Bender; G T Herman
Journal:  J Theor Biol       Date:  1970-12       Impact factor: 2.691

10.  Performance characteristics of a whole-body PET scanner.

Authors:  T R DeGrado; T G Turkington; J J Williams; C W Stearns; J M Hoffman; R E Coleman
Journal:  J Nucl Med       Date:  1994-08       Impact factor: 10.057

View more
  2 in total

1.  MAP reconstruction for Fourier rebinned TOF-PET data.

Authors:  Bing Bai; Yanguang Lin; Wentao Zhu; Ran Ren; Quanzheng Li; Magnus Dahlbom; Frank DiFilippo; Richard M Leahy
Journal:  Phys Med Biol       Date:  2014-02-07       Impact factor: 3.609

2.  Generalized Least-Squares CT Reconstruction with Detector Blur and Correlated Noise Models.

Authors:  J Webster Stayman; Wojciech Zbijewski; Steven Tilley; Jeffrey Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.