Literature DB >> 12541238

In vivo 31P magnetic resonance spectroscopy of human brain at 7 T: an initial experience.

Hao Lei1, Xiao-Hong Zhu, Xiao-Liang Zhang, Kamil Ugurbil, Wei Chen.   

Abstract

In vivo (31)P spectra were acquired from the human primary visual cortex at 7 T. The relaxation times of the cerebral metabolites, intracellular pH, rate constant (k(f)) of the creatine kinase (CK) reaction, and nuclear Overhauser enhancement (NOE) on the detected phosphorus moieties from irradiation of the water spins were measured from normal subjects. With a 5-cm-diameter surface coil, 3D (31)P chemical shift imaging was performed with a spatial resolution of 7.5 ml and an acquisition resolution of 8 min, resulting in a signal-to-noise ratio (SNR) for phosphocreatine (PCr) resonance of 32. The apparent T(1) and T(2) of PCr measured at 7 T were 3.37 +/- 0.29 s and 132.0 +/- 12.8 ms, respectively, which were considerably longer than those of adenosine triphosphate (ATP) (T(1): 1.02-1.27 s; T(2): 25-26 ms). The NOE measured in this study was 24.3% +/- 1.6% for PCr, and 10% for ATP. The k(f) measured in the human primary visual cortex was 0.24 +/- 0.03 s(-1). The results from this study suggest that ultra-high-field strength is advantageous for performing in vivo (31)P magnetic resonance spectroscopy (MRS) in the human brain. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12541238     DOI: 10.1002/mrm.10379

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  55 in total

1.  Higher field strength for proton MR spectroscopy.

Authors:  Oded Gonen
Journal:  AJNR Am J Neuroradiol       Date:  2003-05       Impact factor: 3.825

2.  Measurement of unidirectional Pi to ATP flux in human visual cortex at 7 T by using in vivo 31P magnetic resonance spectroscopy.

Authors:  Hao Lei; Kamil Ugurbil; Wei Chen
Journal:  Proc Natl Acad Sci U S A       Date:  2003-11-11       Impact factor: 11.205

3.  Measurement of creatine kinase reaction rate in human brain using magnetization transfer image-selected in vivo spectroscopy (MT-ISIS) and a volume ³¹P/¹H radiofrequency coil in a clinical 3-T MRI system.

Authors:  Eun-Kee Jeong; Young-Hoon Sung; Seong-Eun Kim; Chun Zuo; Xianfeng Shi; Eric A Mellon; Perry F Renshaw
Journal:  NMR Biomed       Date:  2010-12-29       Impact factor: 4.044

4.  A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Prodromos Parasoglou
Journal:  Neuroimage       Date:  2015-09-13       Impact factor: 6.556

Review 5.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

6.  Quantification of in vivo ³¹P NMR brain spectra using LCModel.

Authors:  Dinesh Kumar Deelchand; Tra-My Nguyen; Xiao-Hong Zhu; Fanny Mochel; Pierre-Gilles Henry
Journal:  NMR Biomed       Date:  2015-04-14       Impact factor: 4.044

Review 7.  Assessing tissue metabolism by phosphorous-31 magnetic resonance spectroscopy and imaging: a methodology review.

Authors:  Yuchi Liu; Yuning Gu; Xin Yu
Journal:  Quant Imaging Med Surg       Date:  2017-12

8.  In vivo 31P MRS of human brain at high/ultrahigh fields: a quantitative comparison of NMR detection sensitivity and spectral resolution between 4 T and 7 T.

Authors:  Hongyan Qiao; Xiaoliang Zhang; Xiao-Hong Zhu; Fei Du; Wei Chen
Journal:  Magn Reson Imaging       Date:  2006-10-04       Impact factor: 2.546

9.  Multimodal neuroimaging provides a highly consistent picture of energy metabolism, validating 31P MRS for measuring brain ATP synthesis.

Authors:  Myriam M Chaumeil; Julien Valette; Martine Guillermier; Emmanuel Brouillet; Fawzi Boumezbeur; Anne-Sophie Herard; Gilles Bloch; Philippe Hantraye; Vincent Lebon
Journal:  Proc Natl Acad Sci U S A       Date:  2009-02-20       Impact factor: 11.205

10.  Precompensation for mutual coupling between array elements in parallel excitation.

Authors:  Yong Pang; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.