Literature DB >> 26508810

Closely-spaced double-row microstrip RF arrays for parallel MR imaging at ultrahigh fields.

Xinqiang Yan1, Rong Xue2, Xiaoliang Zhang3.   

Abstract

Radiofrequency (RF) coil arrays with high count of elements, e.g., closely-spaced multi-row arrays, exhibit superior parallel imaging performance in MRI. However, it is technically challenging and time-consuming to build multi-row arrays due to complex coupling issues. This paper presents a novel and simple method for closely-spaced multi-row RF array designs. Induced current elimination (ICE) decoupling method has shown the capability of reducing coupling between microstrip elements from different rows. In this study, its capability for decoupling array elements from the same row was investigated and validated by bench tests, with an isolation improvement from -8.9 dB to -20.7 dB. Based on this feature, a closely-spaced double-row microstrip array with 16 elements was built at 7T. S21 between any two elements of the 16-channel closely-spaced was better than -14 dB. In addition, its feasibility and performance was validated by MRI experiments. No significant image reconstruction- related noise amplifications were observed for parallel imaging even when reduced factor (R) achieves 4. The experimental results demonstrated that the proposed design might be a simple and efficient approach in fabricating closely-spaced multi-row RF arrays.

Entities:  

Keywords:  Microstrip; RF array; decouple; induced current elimination (ICE); magnetic resonance image (MRI); parallel imaging

Year:  2015        PMID: 26508810      PMCID: PMC4617305          DOI: 10.1007/s00723-015-0712-1

Source DB:  PubMed          Journal:  Appl Magn Reson        ISSN: 0937-9347            Impact factor:   0.831


  33 in total

1.  Imaging brain function in humans at 7 Tesla.

Authors:  E Yacoub; A Shmuel; J Pfeuffer; P F Van De Moortele; G Adriany; P Andersen; J T Vaughan; H Merkle; K Ugurbil; X Hu
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Planar strip array (PSA) for MRI.

Authors:  R F Lee; C R Westgate; R G Weiss; D C Newman; P A Bottomley
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

3.  Microstrip RF surface coil design for extremely high-field MRI and spectroscopy.

Authors:  X Zhang; K Ugurbil; W Chen
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

4.  Analysis of wave behavior in lossy dielectric samples at high field.

Authors:  Qing X Yang; Jinghua Wang; Xiaoliang Zhang; Christopher M Collins; Michael B Smith; Haiying Liu; Xiao-Hong Zhu; J Thomas Vaughan; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

5.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

6.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

7.  Eight-channel phased array coil and detunable TEM volume coil for 7 T brain imaging.

Authors:  G C Wiggins; A Potthast; C Triantafyllou; C J Wiggins; L L Wald
Journal:  Magn Reson Med       Date:  2005-07       Impact factor: 4.668

8.  Two-dimensional sixteen channel transmit/receive coil array for cardiac MRI at 7.0 T: design, evaluation, and application.

Authors:  Christof Thalhammer; Wolfgang Renz; Lukas Winter; Fabian Hezel; Jan Rieger; Harald Pfeiffer; Andreas Graessl; Frank Seifert; Werner Hoffmann; Florian von Knobelsdorff-Brenkenhoff; Valeriy Tkachenko; Jeanette Schulz-Menger; Peter Kellman; Thoralf Niendorf
Journal:  J Magn Reson Imaging       Date:  2012-06-15       Impact factor: 4.813

9.  Hybrid monopole/loop coil array for human head MR imaging at 7T.

Authors:  Xinqiang Yan; Long Wei; Rong Xue; Xiaoliang Zhang
Journal:  Appl Magn Reson       Date:  2015-05-01       Impact factor: 0.831

10.  Transceiver-Phased Arrays for Human Brain Studies at 7 T.

Authors:  Nikolai I Avdievich
Journal:  Appl Magn Reson       Date:  2011-12       Impact factor: 0.831

View more
  6 in total

1.  A Novel Expandable Catheter Wireless Amplified NMR Detector for MR Sensitivity Accessing the Kidney in Rodent Model.

Authors:  Roshan Timilsina; Chunqi Qian
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-01-04       Impact factor: 3.833

2.  Sensitivity enhancement of traveling wave MRI using free local resonators: an experimental demonstration.

Authors:  Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2017-04

3.  Eight-Channel Monopole Array Using ICE Decoupling for Human Head MR Imaging at 7 T.

Authors:  Xinqiang Yan; Long Wei; Suoda Chu; Rong Xue; Xiaoliang Zhang
Journal:  Appl Magn Reson       Date:  2016-04-07       Impact factor: 0.831

4.  A Dedicated 36-Channel Receive Array for Fetal MRI at 3T.

Authors:  Qiaoyan Chen; Guoxi Xie; Chao Luo; Xing Yang; Jin Zhu; Jo Lee; Shi Su; Dong Liang; Xiaoliang Zhang; Xin Liu; Ye Li; Hairong Zheng
Journal:  IEEE Trans Med Imaging       Date:  2018-05-21       Impact factor: 10.048

5.  Evaluation of magnetic resonance image segmentation in brain low-grade gliomas using support vector machine and convolutional neural network.

Authors:  Qifan Yang; Huijuan Zhang; Jun Xia; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2021-01

6.  Wireless MRI Colonoscopy for Sensitive Imaging of Vascular Walls.

Authors:  Xianchun Zeng; Liangliang Chen; Chuan Wang; Jian Wang; Chunqi Qian
Journal:  Sci Rep       Date:  2017-06-26       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.