Design of a capacitively decoupled transmit/receive NMR phased array for high field microscopy at 14.1T.

Xiaozhong Zhang1, Andrew Webb.   

Abstract

A design is presented for a "phased array" of four transmit/receive saddle-geometry volume coils for microimaging at 600 MHz within a 45 mm clear-bore vertical magnet. The small size of the coils, approximately 10 mm in length, and high frequency of operation both present considerable challenges for the design of a phased array. The particular design consists of four saddle coils, stacked vertically, in order to produce an array suitable for imaging samples, typical of many microimaging studies, with a large length:diameter ratio. Optimal coil overlap is used to reduce the mutual inductance between adjacent coils, and capacitive networks are used to maximize the isolation between all of the coils. Standard 50 Omega input impedance preamplifiers are used so that the preamplifiers do not have to be integrated directly into the probe. Isolation between coils was better than 20 dB for all coil pairs. An increase in signal-to-noise of 70 +/- 3% was achieved, averaged over the whole array, compared to a single coil of the same dimensions. High resolution phased array images are shown for ex vivo tissue samples.

Mesh:

Year:  2004        PMID: 15324768     DOI: 10.1016/j.jmr.2004.05.004

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  12 in total

1.  Design and Test of Magnetic Wall Decoupling for Dipole Transmit/Receive Array for MR Imaging at the Ultrahigh Field of 7T.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Long Wei; Rong Xue
Journal:  Appl Magn Reson       Date:  2014-11-27       Impact factor: 0.831

2.  A monopole/loop dual-tuned RF coil for ultrahigh field MRI.

Authors:  Xinqiang Yan; Rong Xue; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-08

3.  Parallel imaging performance investigation of an 8-channel common-mode differential-mode (CMDM) planar array for 7T MRI.

Authors:  Xiaoqing Hu; Xiao Chen; Xin Liu; Hairong Zheng; Ye Li; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

4.  Eight-Channel Monopole Array Using ICE Decoupling for Human Head MR Imaging at 7 T.

Authors:  Xinqiang Yan; Long Wei; Suoda Chu; Rong Xue; Xiaoliang Zhang
Journal:  Appl Magn Reson       Date:  2016-04-07       Impact factor: 0.831

5.  Multi-channel microstrip transceiver arrays using harmonics for high field MR imaging in humans.

Authors:  Bing Wu; Chunsheng Wang; Jonathan Lu; Yong Pang; Sarah J Nelson; Daniel B Vigneron; Xiaoliang Zhang
Journal:  IEEE Trans Med Imaging       Date:  2011-08-30       Impact factor: 10.048

6.  Sensitivity Enhancement of an Inductively Coupled Local Detector Using a HEMT-Based Current Amplifier.

Authors:  Chunqi Qian; Qi Duan; Steve Dodd; Alan Koretsky; Joe Murphy-Boesch
Journal:  Magn Reson Med       Date:  2015-07-20       Impact factor: 4.668

7.  New resonator geometries for ICE decoupling of loop arrays.

Authors:  Xinqiang Yan; John C Gore; William A Grissom
Journal:  J Magn Reson       Date:  2017-02-16       Impact factor: 2.229

8.  In vivo intermolecular zero-quantum coherence MR spectroscopy in the rat spinal cord at 17.6 T: a feasibility study.

Authors:  David Z Balla; Cornelius Faber
Journal:  MAGMA       Date:  2007-09-18       Impact factor: 2.310

9.  Optimizing the ICE decoupling element distance to improve monopole antenna arrays for 7 Tesla MRI.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Rong Xue; John C Gore; William A Grissom
Journal:  Magn Reson Imaging       Date:  2016-07-25       Impact factor: 2.546

10.  Three-element phased-array coil for imaging of rat spinal cord at 7T.

Authors:  Kishore V Mogatadakala; James A Bankson; Ponnada A Narayana
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.