Literature DB >> 25135316

Assessment of metal artefact reduction around dental titanium implants in cone beam CT.

A Parsa1, N Ibrahim, B Hassan, K Syriopoulos, P van der Stelt.   

Abstract

OBJECTIVES: The aim of this study was to investigate if the metal artefact reduction (MAR) tool used in the software of the ORTHOPANTOMOGRAPH(®) OP300 (Instrumentarium Dental, Tuusula, Finland) can improve the gray value levels in post-operative implant scans.
METHODS: 20 potential implant sites were selected from 5 edentulous human dry mandibles. Each mandible was scanned by a CBCT scanner, and images were produced under three different conditions: implant sites drilled but no implants inserted, implants inserted without application of MAR and implants inserted with application of MAR. Using Geomagic(®) Studio 2012 (Geomagic, Morrisville, NC) and 3Diagnosys(®) v. 5.3.1 (3Diemme(®) SRL, Cantù, Italy) software, three scans of each mandible were superimposed. The mean gray value of identical regions of bone around the implants was derived for each condition. The differences between gray value measurements at implant sites derived from different conditions were assessed.
RESULTS: A significant difference was found between mean gray values from the scans with no implants inserted and with implants inserted (with and without MAR) (p = 0.012). No significant difference was revealed for gray values measured from scans with and without MAR (p = 0.975).
CONCLUSIONS: The MAR tool in the software of the ORTHOPANTOMOGRAPH OP300 CBCT scanner does not significantly correct the voxel gray values affected by the metal artefact in the vicinity of an implant in human dry mandibles.

Entities:  

Keywords:  artefacts; cone beam computed tomography; dental implants; titanium

Year:  2014        PMID: 25135316      PMCID: PMC4170846          DOI: 10.1259/dmfr.20140019

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  24 in total

1.  Deriving Hounsfield units using grey levels in cone beam computed tomography.

Authors:  P Mah; T E Reeves; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2010-09       Impact factor: 2.419

2.  Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT.

Authors:  F G Draenert; E Coppenrath; P Herzog; S Müller; U G Mueller-Lisse
Journal:  Dentomaxillofac Radiol       Date:  2007-05       Impact factor: 2.419

3.  Accuracy of measurements of mandibular anatomy in cone beam computed tomography images.

Authors:  John B Ludlow; William Stewart Laster; Meit See; L'Tanya J Bailey; H Garland Hershey
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2006-08-04

4.  Correlation between bone quality evaluated by cone-beam computerized tomography and implant primary stability.

Authors:  Young-Dai Song; Sang-Ho Jun; Jong-Jin Kwon
Journal:  Int J Oral Maxillofac Implants       Date:  2009 Jan-Feb       Impact factor: 2.804

5.  On cone-beam computed tomography artifacts induced by titanium implants.

Authors:  Ralf Kurt Willy Schulze; Dorothea Berndt; Bernd d'Hoedt
Journal:  Clin Oral Implants Res       Date:  2009-10-21       Impact factor: 5.977

6.  Reliability of voxel gray values in cone beam computed tomography for preoperative implant planning assessment.

Authors:  Azin Parsa; Norliza Ibrahim; Bassam Hassan; Alessandro Motroni; Paul van der Stelt; Daniel Wismeijer
Journal:  Int J Oral Maxillofac Implants       Date:  2012 Nov-Dec       Impact factor: 2.804

7.  Influence of cone beam CT scanning parameters on grey value measurements at an implant site.

Authors:  A Parsa; N Ibrahim; B Hassan; A Motroni; P van der Stelt; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2012-08-29       Impact factor: 2.419

8.  Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth.

Authors:  B Bechara; C Alex McMahan; W S Moore; M Noujeim; F B Teixeira; H Geha
Journal:  Dentomaxillofac Radiol       Date:  2013-03-21       Impact factor: 2.419

9.  Fate of the buccal bone at implants placed early, delayed, or late after tooth extraction analyzed by cone beam CT: 10-year results from a randomized, controlled, clinical study.

Authors:  Lars Schropp; Ann Wenzel; Rubens Spin-Neto; Andreas Stavropoulos
Journal:  Clin Oral Implants Res       Date:  2014-06-02       Impact factor: 5.977

10.  Post-processing sets of tilted CT volumes as a method for metal artifact reduction.

Authors:  Hendrik Ballhausen; Michael Reiner; Ute Ganswindt; Claus Belka; Matthias Söhn
Journal:  Radiat Oncol       Date:  2014-05-15       Impact factor: 3.481

View more
  18 in total

1.  Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts.

Authors:  I S Q Bezerra; F S Neves; T V Vasconcelos; G M B Ambrosano; D Q Freitas
Journal:  Dentomaxillofac Radiol       Date:  2015-03-12       Impact factor: 2.419

2.  Evaluation of a metal artefact reduction tool on different positions of a metal object in the FOV.

Authors:  Polyane M Queiroz; Gustavo M Santaella; Thais D J da Paz; Deborah Q Freitas
Journal:  Dentomaxillofac Radiol       Date:  2017-02-17       Impact factor: 2.419

3.  Influence of acquisition parameters on the magnitude of cone beam computed tomography artifacts.

Authors:  Deborah Queiroz Freitas; Rocharles Cavalcante Fontenele; Eduarda Helena Leandro Nascimento; Taruska Ventorini Vasconcelos; Marcel Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2018-06-27       Impact factor: 2.419

4.  Effect of anatomical region on the formation of metal artefacts produced by dental implants in cone beam computed tomographic images.

Authors:  Alessiana Helena Machado; Karolina Aparecida Castilho Fardim; Camila Furtado de Souza; Bruno Salles Sotto-Maior; Neuza Maria Souza Picorelli Assis; Karina Lopes Devito
Journal:  Dentomaxillofac Radiol       Date:  2018-01-10       Impact factor: 2.419

5.  Does the size of an object containing dental implant affect the expression of artifacts in cone beam computed tomography imaging?

Authors:  Mahkameh Moshfeghi; Yaser Safi; Ingrid Różyło-Kalinowska; Shiva Gandomi
Journal:  Head Face Med       Date:  2022-06-29       Impact factor: 2.246

6.  Artefacts at different distances from titanium and zirconia implants in cone-beam computed tomography: effect of tube current and metal artefact reduction.

Authors:  Arthur Xavier Maseti Mancini; Matheus Urias Cruz Santos; Hugo Gaêta-Araujo; Camila Tirapelli; Ruben Pauwels; Christiano Oliveira-Santos
Journal:  Clin Oral Investig       Date:  2021-02-05       Impact factor: 3.573

7.  Quantitative analysis of metal artefacts of dental implant in CBCT image by correlation analysis to micro-CT: A microstructural study.

Authors:  Chang-Ki Min; Kyoung-A Kim
Journal:  Dentomaxillofac Radiol       Date:  2020-10-08       Impact factor: 2.419

8.  Inter- and intraobserver reproducibility of buccal bone measurements at dental implants with cone beam computed tomography in the esthetic region.

Authors:  Kirsten W Slagter; Gerry M Raghoebar; Arjan Vissink; Henny J A Meijer
Journal:  Int J Implant Dent       Date:  2015-04-18

9.  Effect of Dental Implant Metal Artifacts on Accuracy of Linear Measurements by Two Cone-Beam Computed Tomography Systems Before and After Crown Restoration.

Authors:  Hoorieh Bashizadeh Fakhar; Roxana Rashtchian; Milad Parvin
Journal:  J Dent (Tehran)       Date:  2017-11

10.  Soft tissue coverage on the segmentation accuracy of the 3D surface-rendered model from cone-beam CT.

Authors:  J K Dusseldorp; H C Stamatakis; Y Ren
Journal:  Clin Oral Investig       Date:  2016-05-21       Impact factor: 3.573

View more