Quantitative analysis of metal artefacts of dental implant in CBCT image by correlation analysis to micro-CT: A microstructural study.

Chang-Ki Min1,2, Kyoung-A Kim1,2.   

Abstract

OBJECTIVES: Quantification of dental implant metal artefacts in CBCT images using correlation analysis of trabecular microstructural parameters from CBCT and micro-CT, and analysis of the effect of varying the angular position of the subject.
METHODS: Polyurethane synthetic bone blocks were first scanned without implants by micro-CT and CBCT. Two dental implants were then placed parallel in the bone blocks and these specimens were scanned by CBCT with different alpha angles. Three volumes of interest (VOI) were set for further analysis. Six microstructural parameters were measured: trabecular thickness (TbTh), trabecular spacing (ThSp), bone volume per total volume (BV/TV), bone surface per total volume (BS/TV), connectivity density (CD) andfractal dimension (FD). Micro-CT measurements were used as a gold standard for CBCT. Spearman correlation coefficients for each microstructural parameter from CBCT and micro-CT were calculated and compared using Steiger's Z test.
RESULTS: Without the implants, in VOI1, the Spearman correlation coefficients of TbTh, TbSp, BV/TV, BS/TV, CD and FD were 0.599, 0.76, 0.552, 0.566, 0.664 and 0.607, respectively. With the implants, the correlation coefficients decreased sharply in VOI1. As the alpha angle increased from zero to 90°, the correlation coefficients increased and became significant. Similar results appeared in VOI2. In contrast, in VOI3, the correlation coefficient decreased as the alpha angle increased.
CONCLUSIONS: Metal artefacts were successfully quantified using microstructural parameters in terms of the image quality of the CBCT. Changes in alpha angle affected the quality of the CBCT image.

Entities:  

Keywords:  Artefacts; Cone-beam Computed Tomography; Dental implant; Diagnostic Imaging

Mesh:

Substances:

Year:  2020        PMID: 33002369      PMCID: PMC7923071          DOI: 10.1259/dmfr.20200365

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  39 in total

Review 1.  Artefacts in CBCT: a review.

Authors:  R Schulze; U Heil; D Gross; D D Bruellmann; E Dranischnikow; U Schwanecke; E Schoemer
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

2.  Reducing metal artifacts between implants in cone-beam CT by adjusting angular position of the subject.

Authors:  Chang-Ki Min; Kyoung-A Kim
Journal:  Oral Radiol       Date:  2020-07-07       Impact factor: 1.852

3.  Comparison of micro-CT and cone beam CT on the feasibility of assessing trabecular structures in mandibular condyle.

Authors:  Xin Liang; Zuyan Zhang; Jianping Gu; Zhihui Wang; Bart Vandenberghe; Reinhilde Jacobs; Jie Yang; Guowu Ma; Haibin Ling; Xuchen Ma
Journal:  Dentomaxillofac Radiol       Date:  2017-04-26       Impact factor: 2.419

4.  In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography.

Authors:  Goran I Benic; Manuel Sancho-Puchades; Ronald E Jung; Hans Deyhle; Christoph H F Hämmerle
Journal:  Clin Oral Implants Res       Date:  2012-10-29       Impact factor: 5.977

5.  Assessment of metal artefact reduction around dental titanium implants in cone beam CT.

Authors:  A Parsa; N Ibrahim; B Hassan; K Syriopoulos; P van der Stelt
Journal:  Dentomaxillofac Radiol       Date:  2014-08-19       Impact factor: 2.419

6.  Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscences.

Authors:  Sergio Lins de-Azevedo-Vaz; Priscila Dias Peyneau; Laura Ricardina Ramirez-Sotelo; Karla de Faria Vasconcelos; Paulo Sérgio Flores Campos; Francisco Haiter-Neto
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2016-01-28

7.  Metal artefact reduction with cone beam CT: an in vitro study.

Authors:  B B Bechara; W S Moore; C A McMahan; M Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2012-01-12       Impact factor: 2.419

8.  Reducing metal artifacts in cone-beam CT images by preprocessing projection data.

Authors:  Yongbin Zhang; Lifei Zhang; X Ronald Zhu; Andrew K Lee; Mark Chambers; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-12-08       Impact factor: 7.038

9.  Cone beam computed tomography artefacts around dental implants with different materials influencing the detection of peri-implant bone defects.

Authors:  Martina Schriber; Andy Wai Kan Yeung; Valerie G A Suter; Daniel Buser; Yiu Yan Leung; Michael M Bornstein
Journal:  Clin Oral Implants Res       Date:  2020-03-23       Impact factor: 5.977

10.  Evaluation of cervical range of motion and isometric neck muscle strength: reliability and validity.

Authors:  Thomas Tai Wing Chiu; Kai Lo Sing
Journal:  Clin Rehabil       Date:  2002-12       Impact factor: 3.477

View more
  1 in total

1.  Does the size of an object containing dental implant affect the expression of artifacts in cone beam computed tomography imaging?

Authors:  Mahkameh Moshfeghi; Yaser Safi; Ingrid Różyło-Kalinowska; Shiva Gandomi
Journal:  Head Face Med       Date:  2022-06-29       Impact factor: 2.246

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.