Impact of a vendor-specific motion-correction algorithm on image quality, interpretability, and diagnostic performance of daily routine coronary CT angiography: influence of heart rate on the effect of motion-correction.

Heon Lee1, Jeong A Kim, Ji Sung Lee, Jon Suh, Sang Hyun Paik, Jai Soung Park.   

Abstract

To investigate the impact of a vendor-specific motion-correction algorithm on morphological assessment of coronary arteries using coronary CT angiography (cCTA) and to evaluate the influence of heart rate (HR) on the motion-correction effect of this algorithm. Eighty-four patients (mean age 56.3 ± 11.4 years; 53 males) were divided into two groups with a HR of ≥65 and <65 bpm during cCTA, respectively. Images were assigned quality scores (graded 1-4) on coronary segments. Interpretability was defined as a grade >1. Catheter angiography was used to determine the diagnostic accuracy of cCTA for detecting significant stenosis (≥50 %). We compared the image quality, interpretability and diagnostic accuracy between the standard and motion-correction reconstructions in both groups. The motion-correction reconstructions showed significantly (p < 0.05) higher image quality in the proximal and middle right coronary artery (RCA) in the low HR group (57.2 ± 5.0 bpm; n = 51) and proximal-to-distal RCA, posterior descending artery, and proximal and distal left circumflex artery in the high HR group (71.1 ± 4.6 bpm; n = 33). The per-segment interpretability was significantly higher using motion-correction algorithm in the middle RCA in the low HR group and in the proximal and middle RCA in high HR group. Overall, the image quality and interpretability were improved using motion-correction reconstructions in both groups (p < 0.05). Motion-correction reconstruction demonstrated higher (p < 0.05) diagnostic accuracy in 25 patients from both groups. Use of the motion-correction algorithm improves the overall image quality and interpretability of cCTA in both groups. However, it may be more beneficial to the patients with a higher HR.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25038955     DOI: 10.1007/s10554-014-0499-4

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  21 in total

1.  Quantification of 3-D coronary arterial motion using clinical biplane cineangiograms.

Authors:  Z Ding; M H Friedman
Journal:  Int J Card Imaging       Date:  2000-10

2.  Radiation dose from single-heartbeat coronary CT angiography performed with a 320-detector row volume scanner.

Authors:  Andrew J Einstein; Carl D Elliston; Andrew E Arai; Marcus Y Chen; Richard Mather; Gregory D N Pearson; Robert L Delapaz; Edward Nickoloff; Ajoy Dutta; David J Brenner
Journal:  Radiology       Date:  2010-03       Impact factor: 11.105

Review 3.  Computed tomography coronary angiography.

Authors:  Stephan Achenbach
Journal:  J Am Coll Cardiol       Date:  2006-11-01       Impact factor: 24.094

4.  Coronary artery imaging during preoperative CT staging: preliminary experience with 64-slice multidetector CT in 99 consecutive patients.

Authors:  Damien Delhaye; Martine Remy-Jardin; Céline Rozel; Catherine Dusson; Alain Wurtz; Valérie Delannoy-Deken; Alain Duhamel; Jacques Remy
Journal:  Eur Radiol       Date:  2006-10-24       Impact factor: 5.315

5.  Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability.

Authors:  David Matt; Hans Scheffel; Sebastian Leschka; Thomas G Flohr; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  AJR Am J Roentgenol       Date:  2007-09       Impact factor: 3.959

6.  High-pitch thoracic CT with simultaneous assessment of coronary arteries: effect of heart rate and heart rate variability on image quality and diagnostic accuracy.

Authors:  Michael Scharf; Ricarda Bink; Matthias S May; Christian Hentschke; Stephan Achenbach; Michael Uder; Michael M Lell
Journal:  JACC Cardiovasc Imaging       Date:  2011-06

7.  Randomized comparison of 64-slice single- and dual-source computed tomography coronary angiography for the detection of coronary artery disease.

Authors:  Stephan Achenbach; Ulrike Ropers; Axel Kuettner; Katharina Anders; Tobias Pflederer; Sei Komatsu; Werner Bautz; Werner G Daniel; Dieter Ropers
Journal:  JACC Cardiovasc Imaging       Date:  2008-03

8.  Optimal systolic and diastolic reconstruction windows for coronary CT angiography using dual-source CT.

Authors:  Harald Seifarth; Susanne Wienbeck; Michael Püsken; Kai-Uwe Juergens; David Maintz; Christian Vahlhaus; Walter Heindel; Roman Fischbach
Journal:  AJR Am J Roentgenol       Date:  2007-12       Impact factor: 3.959

9.  Diagnostic performance of coronary angiography by 64-row CT.

Authors:  Julie M Miller; Carlos E Rochitte; Marc Dewey; Armin Arbab-Zadeh; Hiroyuki Niinuma; Ilan Gottlieb; Narinder Paul; Melvin E Clouse; Edward P Shapiro; John Hoe; Albert C Lardo; David E Bush; Albert de Roos; Christopher Cox; Jeffery Brinker; João A C Lima
Journal:  N Engl J Med       Date:  2008-11-27       Impact factor: 91.245

10.  Duration of diastole and its phases as a function of heart rate during supine bicycle exercise.

Authors:  Charles S Chung; Mustafa Karamanoglu; Sándor J Kovács
Journal:  Am J Physiol Heart Circ Physiol       Date:  2004-06-24       Impact factor: 4.733

View more
  7 in total

Review 1.  Cardiovascular imaging 2014 in the International Journal of Cardiovascular Imaging.

Authors: 
Journal:  Int J Cardiovasc Imaging       Date:  2015-03       Impact factor: 2.357

2.  Second-generation motion correction algorithm improves diagnostic accuracy of single-beat coronary CT angiography in patients with increased heart rate.

Authors:  Junfu Liang; Ying Sun; Ziqing Ye; Yanchun Sun; Lei Xu; Zhen Zhou; Brian Thomsen; Jianying Li; Zhonghua Sun; Zhanming Fan
Journal:  Eur Radiol       Date:  2019-01-07       Impact factor: 5.315

3.  Effect of a Novel Intracycle Motion Correction Algorithm on Dual-Energy Spectral Coronary CT Angiography: A Study with Pulsating Coronary Artery Phantom at High Heart Rates.

Authors:  Yan Xing; Yuan Zhao; Ning Guo; Cun-Xue Pan; Gulina Azati; Yan-Wei Wang; Wen-Ya Liu
Journal:  Korean J Radiol       Date:  2017-09-21       Impact factor: 3.500

4.  Influence of Heart Rate and Innovative Motion-Correction Algorithm on Coronary Artery Image Quality and Measurement Accuracy Using 256-Detector Row Computed Tomography Scanner: Phantom Study.

Authors:  Jeong Bin Park; Yeon Joo Jeong; Geewon Lee; Nam Kyung Lee; Jin You Kim; Ji Won Lee
Journal:  Korean J Radiol       Date:  2018-12-27       Impact factor: 3.500

Review 5.  Clinical Applications of Wide-Detector CT Scanners for Cardiothoracic Imaging: An Update.

Authors:  Eun Ju Kang
Journal:  Korean J Radiol       Date:  2019-12       Impact factor: 3.500

6.  Heart Rate-Dependent Degree of Motion Artifacts in Coronary CT Angiography Acquired by a Novel Purpose-Built Cardiac CT Scanner.

Authors:  Milán Vecsey-Nagy; Ádám Levente Jermendy; Márton Kolossváry; Borbála Vattay; Melinda Boussoussou; Ferenc Imre Suhai; Alexisz Panajotu; Judit Csőre; Sarolta Borzsák; Daniele Mariastefano Fontanini; Csaba Csobay-Novák; Béla Merkely; Pál Maurovich-Horvat; Bálint Szilveszter
Journal:  J Clin Med       Date:  2022-07-26       Impact factor: 4.964

7.  Improvement of Image Quality and Diagnostic Performance by an Innovative Motion-Correction Algorithm for Prospectively ECG Triggered Coronary CT Angiography.

Authors:  Zhen-Nan Li; Wei-Hua Yin; Bin Lu; Hong-Bing Yan; Chao-Wei Mu; Yang Gao; Zhi-Hui Hou; Zhi-Qiang Wang; Kun Liu; Ashley H Parinella; Jonathon A Leipsic
Journal:  PLoS One       Date:  2015-11-16       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.